VENTING INSTALLATION INSTRUCTIONS

Installation Precautions

Installation Planning

7

VENTING INSTALLATION INSTRUCTIONS

NOTICE: Read these instructions completely be- fore attempting installation.

These models are tested and approved for use with DESA (direct- vent) pipe components and terminations.

The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance.

These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines:

When venting system terminates horizontally on an outside wall, you must install a standoff if the termination cap is to be in- stalled directly on a combustible finish such as vinyl, wood, stucco, etc.

Never run the vent downward as this may cause excessive tem- peratures which could cause a fire.

Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11).

Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

NOTICE: Failure to follow these instructions will void the warranty.

NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance.

INSTALLATION PRECAUTIONS

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting system (Do not cut or alter vent components)

Installation of any component part not manufactured or ap- proved by DESA

Installation other than as instructed by these instructions

WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serv- ing a separate solid fuel burning appliance. Each direct-vent gas appliance must use a separate vent system. Do not use common vent systems.

WARNING: Vent pipe air space clearances to com- bustibles are 1" on all sides except on the horizontal sections, which require 2" clearances from the top of the pipe. Where the termination cap penetrates a com- bustible wall, 1" air space clearance is required.

INSTALLATION PLANNING

There are two basic types of direct-vent installation:

Horizontal Termination

Vertical Termination

Horizontal Termination Installation

IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Horizontal installations using round termi- nation require exterior portion of wall firestop available only in vent kit HTK (see Figure 14, page 10).

1.Set the fireplace in its desired location and determine the route your horizontal venting will take. Do not secure the fireplace until all venting has been installed. Some installations require sliding the fireplace in and out of position to make final vent- ing connections. Figures 14 through 18 on pages 10 through 12 show different configurations for venting with horizontal termination that will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path of your desired venting route. If they are, you may want to adjust the location of the fireplace.

For morevisit www..com

111250-01A

Page 7
Image 7
Desa VT36PA, CTDV36NRA, VT36NA Venting Installation Instructions, Installation Precautions, Installation Planning

VT36PA, CTDV36NRA, VT36NA specifications

The Desa VT36NA, CTDV36NRA, and VT36PA are popular models in the realm of gas fireplaces, providing efficient heating solutions while enhancing the aesthetic appeal of any space. These models are designed to deliver comfort, convenience, and sophisticated design, making them ideal choices for residential and commercial applications.

One of the standout features of these models is their innovative heating technology. Utilizing advanced gas control systems, they offer precise temperature management, allowing users to enjoy consistent warmth with ease. The inclusion of a variable speed blower ensures better air circulation, maximizing the heating efficiency and comfort level throughout the room.

The VT36NA model boasts a direct vent design, which means it draws air for combustion from outside, ensuring that indoor air quality remains untainted. This feature is particularly beneficial in tightly sealed homes where indoor air quality can be compromised. The dual venting option also provides flexibility in installation, allowing for either horizontal or vertical venting, which adds to the model's versatility.

The CTDV36NRA, on the other hand, is designed with a contemporary aesthetic in mind, featuring a sleek and modern front that complements any modern décor. With a variable flame height option, users can easily adjust the fire intensity according to their preferences, providing both ambiance and warmth. The accent lighting feature further enhances the visual appeal, allowing the fireplace to become a focal point in any room.

The VT36PA model is equipped with enhanced safety features, including an automatic shut-off system and flame supervision devices. These safety measures provide peace of mind while operating, ensuring that the fireplace is both effective and secure for regular use. Additionally, the model is capable of using either natural gas or propane, adding versatility to fuel options depending on user preference or availability.

In terms of energy efficiency, all three models meet rigorous standards, making them environmentally friendly options for heating. With their low emissions and high-efficiency ratings, they contribute to reducing overall energy consumption.

Overall, the Desa VT36NA, CTDV36NRA, and VT36PA models offer a blend of functionality, modern technology, and aesthetic appeal. With their range of features and customizable options, they are ideal for those looking to enhance their living spaces with reliable heating solutions that also serve as elegant focal points. Whether for a cozy family gathering or a modern entertainment area, these fireplaces provide both comfort and style, making them excellent additions to any home.