Desa CTDV36NRA, VT36PA, VT36NA installation manual Observed Problem Possible Cause Remedy

Models: VT36PA CTDV36NRA VT36NA

1 38
Download 38 pages 6.52 Kb
Page 30
Image 30

30

TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 28) or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Thermopile leads disconnected or im-

3.

Reconnect leads

 

 

properly connected

 

 

 

 

4.

Thermopile is defective

4.

Replace thermopile

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

company

 

2.

Burner porting or orifice clogged

2.

Clean burner (see Cleaning and Main-

 

 

 

 

tenance, page 28) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 28) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Heater produces a whistling noise when

1.

Turning gas control knob to HI position

1.

Turn gas control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP or natural gas company

 

3.

Dirty or partially clogged burner orifice

3.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 28) or replace burner orifice

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set so that the flame does

 

 

 

 

not excessively impinge on it

 

2.

Debris around burner air mixer

2.

Inspect the opening at the base of the

 

 

 

 

burner to see that it is NOT packed with

 

 

 

 

any type of material

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common. If noise is excessive, contact qualified service person

Remote does not function

1. Battery is not installed or battery power

 

is low

1.Replace 9-volt batteries in receiver and remote control

For..com

111250-01A

Page 30
Image 30
Desa CTDV36NRA, VT36PA, VT36NA installation manual Observed Problem Possible Cause Remedy

VT36PA, CTDV36NRA, VT36NA specifications

The Desa VT36NA, CTDV36NRA, and VT36PA are popular models in the realm of gas fireplaces, providing efficient heating solutions while enhancing the aesthetic appeal of any space. These models are designed to deliver comfort, convenience, and sophisticated design, making them ideal choices for residential and commercial applications.

One of the standout features of these models is their innovative heating technology. Utilizing advanced gas control systems, they offer precise temperature management, allowing users to enjoy consistent warmth with ease. The inclusion of a variable speed blower ensures better air circulation, maximizing the heating efficiency and comfort level throughout the room.

The VT36NA model boasts a direct vent design, which means it draws air for combustion from outside, ensuring that indoor air quality remains untainted. This feature is particularly beneficial in tightly sealed homes where indoor air quality can be compromised. The dual venting option also provides flexibility in installation, allowing for either horizontal or vertical venting, which adds to the model's versatility.

The CTDV36NRA, on the other hand, is designed with a contemporary aesthetic in mind, featuring a sleek and modern front that complements any modern décor. With a variable flame height option, users can easily adjust the fire intensity according to their preferences, providing both ambiance and warmth. The accent lighting feature further enhances the visual appeal, allowing the fireplace to become a focal point in any room.

The VT36PA model is equipped with enhanced safety features, including an automatic shut-off system and flame supervision devices. These safety measures provide peace of mind while operating, ensuring that the fireplace is both effective and secure for regular use. Additionally, the model is capable of using either natural gas or propane, adding versatility to fuel options depending on user preference or availability.

In terms of energy efficiency, all three models meet rigorous standards, making them environmentally friendly options for heating. With their low emissions and high-efficiency ratings, they contribute to reducing overall energy consumption.

Overall, the Desa VT36NA, CTDV36NRA, and VT36PA models offer a blend of functionality, modern technology, and aesthetic appeal. With their range of features and customizable options, they are ideal for those looking to enhance their living spaces with reliable heating solutions that also serve as elegant focal points. Whether for a cozy family gathering or a modern entertainment area, these fireplaces provide both comfort and style, making them excellent additions to any home.