Desa CTDV36NRA Horizontal System Installation Using TWO Elbows, Venting with Two 90 Elbows

Models: VT36PA CTDV36NRA VT36NA

1 38
Download 38 pages 6.52 Kb
Page 12
Image 12

12

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

VENTING INSTALLATION

INSTRUCTIONS

Continued

HORIZONTAL SYSTEM INSTALLATION USING TWO 90°

ELBOWS

The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.

Venting with Two 90° Elbows

 

Vertical (V)

Horizontal (H1)

Horizontal (H1) +

 

 

 

Horizontal (H2)

45° Elbow

5' min.

2' max.

6' max.

 

6' min.

4' max.

12' max.

 

7' min.

6' max.

18' max.

 

8' min.

8' max.

20' max.

 

20' max.

8' max.

20' max.

 

Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

Venting with Two 90° Elbows

 

Vertical (V)

Horizontal (H1) +

 

 

Horizontal (H2)

 

5' min.

6' max.

 

6' min.

12' max.

 

7' min.

18' max.

45° Elbow

8' min.

20' max.

 

20' max.

20' max.

 

Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows with Termination at 90° with Fireplace

For..com

111250-01A

Page 12
Image 12
Desa CTDV36NRA, VT36PA, VT36NA Horizontal System Installation Using TWO Elbows, Venting with Two 90 Elbows