Windsor D250(115V) 10070100 manual Maintenance, Vacuum Motor Carbon Brushes Replacement Windsor

Page 9
Vacuum Motor Carbon Brushes Replacement (Windsor)
Wire Terminal

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.

VACUUM MOTOR REPLACEMENT

1.Turn off all switches and unplug machine.

2.Remove recovery tank.

3.Locate the vacuum motor wires and disconnect at the connector.

4.Remove the vacuum motor.

5.Reverse process to install vacuum motor.

SOLUTION PUMP REPLACEMENT

1.Turn off all switches and unplug the machine.

2.Remove recovery tank.

3.Remove solution hoses from fittings in pump.

4.Remove the (2) screws that fasten the pump to the frame.

5.Reverse process to install pump.

Vacuum Motor Carbon Brushes Replacement (Windsor)

 

End Cap

Carbon

WARNING: The green

Brushes

ground wire must be

 

attached for safe operation.

 

See wiring diagram.

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

WARNING: The green 38 [9.5mm]

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

MAINTENANCE

Vacuum Motor Carbon Brushes Replacement (Ametek)

 

End Cap

Carbon

WARNING: The green

Brushes

ground wire must be

 

attached for safe operation.

 

See wiring diagram.

Note: When replacing carbon brushes loosen wire terminal BEFORE removing screws on bracket.

Wire

Terminal

Note:

Place stop in groove.

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

Vacuum Motor Carbon Brushes Replacement (Ametek)Manual background 3/8 (9.5mm)

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

D-250 86038570 05/11/07

8

Image 9
Contents CARPET EXTRACTOR MODEL D250 115V Beginning with Serial NoOperating Instructions ENG Read these instructions before operating the machineINSPECTION TABLE OF CONTENTSIMPORTANT SAFETY INSTRUCTIONS SAFETY INSTRUCTIONSREAD ALL INSTRUCTIONS BEFORE USING THIS MACHINE SAVE THESE INSTRUCTIONSGROUNDING INSTRUCTIONS ELECTRICALGROUNDING INSTRUCTIONS OPERATIONS OPERATION DAILY MAINTENANCE MAINTENANCEPERIODIC MAINTENANCE MONTHLY MAINTENANCEMAINTENANCE SERVICE SCHEDULEDAILY WEEKLYVacuum Motor Carbon Brushes Replacement Windsor Vacuum Motor Carbon Brushes Replacement AmetekWARNING The green D-250 PUMP MAINTENANCE TROUBLE SHOOTING CHART TROUBLESHOOTINGPROBLEM SOLUTIONTECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONSD-250 86038570 05/11/07 RECOVERY TANK ASSEMBLY RECOVERY TANK ASSEMBLY CONTROL PANEL GROUP CONTROL PANEL GROUP VACUUM GROUP LOWER VACUUM GROUP LOWER PUMP & HEATER GROUP 200 PSI PUMP & HEATER GROUP 200 PSI SOLUTION TANK ASSEMBLY SOLUTION TANK ASSEMBLY SPARE PARTS SUGGESTED SPARE PARTS D-250 115V WIRING DIAGRAM86038570 05/11/07