N
Tilbehør
For å forenkle installasjonen og spare tid, kan det være at din installasjon krever noe av tilbehøret som er listet opp nedenfor:
WD100
FDA Utstyrspakke med
XCT100 | plant kanaladapter |
Kondensavskiller | |
DGW/B | Gitterluke for |
SP100 | luftutskiftning |
Muffeplate | |
XAA | Luftadapter for mur |
VC10 | Avtrekksdeksel |
WT10 | |
XF/FM | Plan rørkanal |
| (plast/metall) |
| (plast 234 x 29 mm |
S
Tillbehör
I listan nedan hittar du hjälpmedel som kan vara av nytta under installationen:
WD100 Väggtrumma
CFWG100 Väggaller
FDA Adaptorsats för planmontering
XCT100 Kondensavledare DGW/B Luftregleringsgaller SP100 Mufförbindningsplatta XAA Adapter
VC10 Ventilhuv
WT10 Avspänningssats XF/FM Planmontering
(plast/metall) (plast 234 x 29 mm) (metall 230 x 25 mm)
I
Accessori opzionali
Per un’installazione più facile e veloce, potrebbero essere necessari alcuni degli accessori sottoelencati:
WD100 Condotto per parete CFWG100 Grata per parete
FDA Kit adattatore per condotto piatto
XCT100 Pozzetto di intercettazione della condensa
DGW/B Grata dello sportello di ricambio aria
SP100 Piastra di imbocco XAA Adattatore per mattoni
traforati
VC10 Cappottatura di ventilazione
WT10 Kit di terminazione condotti
XF/FM Condotti piatti
GR
Συµπληρωµατικές Επιλ
Για γρήγ
εγκατάσταση, η εγκατάσταση σας µπ απ ανα
WD100 | Αγωγ |
CFWG100 Κιγκλίδωµα τ | |
FDA | Πρ |
| επίπεδ |
XCT100 | Ατµ |
DGW/B | Κιγκλίδωµα π |
| ανανέωσης αέρα |
SP100 | Πλάκα |
XAA | Πρ |
| τ |
VC10 | Κάλυµµα αεραγωγ |
WT10 | Σύν |
| τερµατισµ |
XF/FM | Επίπεδ |
| (πλαστικ |
GB
IMPORTANT
1.READ ALL THESE INSTRUCTIONS & WARNINGS FULLY BEFORE COMMENCING INSTALLATION.
2.INSTALLATIONS AND WIRING MUST CONFORM TO CURRENT IEE REGULATIONS (UK), LOCAL OR APPROPRIATE REGULATIONS (OTHER COUNTRIES). IT IS THE INSTALLER’S RESPONSIBILITY TO ENSURE THAT THE APPROPRIATE
BUILDING CODES OF PRACTICE ARE ADHERED TO.
3.A QUALIFIED ELECTRICIAN MUST SUPERVISE ALL INSTALLATIONS.
4.THESE APPLIANCES ARE INTENDED FOR CONNECTION TO FIXED WIRING
5.CHECK THAT THE ELECTRICAL RATING SHOWN ON THE FAN MATCHES THE MAINS SUPPLY.
6.WARNING: THESE APPLIANCES MUST BE EARTHED.
7.SITE AWAY FROM DIRECT SOURCES OF HEAT (I.E.: GAS COOKERS OR
8.WHEN THE FAN IS INSTALLED IN AROOM CONTAINING AFUEL BURNING APPLIANCE, PRECAUTIONS MUST BE TAKEN TO AVOID THE BACKFLOW OF GASES INTO THE ROOM FROM THE OPEN FLUE OF THE FUEL BURNING APPLIANCE.
9.ENSURE THAT ALL RELEVANT SAFETY PRECAUTIONS (CORRECT EYE PROTECTION AND PROTECTIVE CLOTHING ETC) ARE TAKEN WHEN INSTALLING AND MAINTAINING THIS FAN.
10.GENERAL GUIDANCE FOR SITING THE FAN SEE “FIG. G”. ALWAYS SITE FAN AS HIGH AS POSSIBLE
11.IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THAN THE FAN A CONDENSATION TRAP (XCT100) MUST BE FITTED AS CLOSE AS POSSIBLE TO THE FAN.
VK10 | metall 230 x 25 mm) |
FD100 | Fleksibel rørkanal |
WDC5 | |
XCMK | Sett for montering i |
XBP | himling |
EFT | tilbakeslippsklaff |
Lettmontert | |
GMK | |
Sett for montering i | |
PDXGF | vindu |
Fettfilter |
Nedenfor er det listet opp enkelte reservedeler som er tilgjengelige. Se baksiden på denne trykksaken for bestillingsinformasjon:
41520SK
41528SK Rund muffe (komplett) 41731SK Motor (DX200) 41733SK Motor (CF20/CF20T/
DX200T)
41782SK
41735SK
41736SK
(CF20T)
41737SK Frontdeksel kompl. med mottrykksplate (DX200)
41738SK Frontdeksel kompl. med mottrykksplate (DX200T)
41739SK Frontdeksel kompl. med mottrykksplate (CF20/CF20T)
41740SK Innfatningsprofil (komplett)
41741SK
41742SK Viftehjul (komplett)
VK10 Väggventilsats FD100 Flexibel
ledningsdragning
WDC5 Skruvdriftsklämmor XCMK Takmonteringssats
XBP Svart reglerventil
EFT Avspänningssats GMK Glasmonteringssats PDXGF Smörjningsfilter
I listan nedan hittar du reservdelar. Du hittar beställningsinformation på denna bruksanvisnings baksida:
41520SK Fastsättningssats (komplett)
41528SK Mufförbindning (komplett sortiment)
41731SK Motor (DX200) 41733SK Motor (CF20/CF20T/
DX200T)
41782SK
41735SK
41736SK
41737SK Främre skydd med skärm (DX200)
41738SK Främre skydd med skärm (DX200T)
41739SK Främre skydd med skärm (CF20/CF20T)
41740SK Ramformning (komplett sortiment)
41741SK Dragsnöresmontering (CF20/CF20T)
41742SK Fläkthjul (komplett sortiment)
(plastica/metallo) (plastica 234 x 29mm, metallo 230 x 25mm)
VK10 Kit di ventilazione per parete
FD100 Condotti flessibili WDC5 Fermagli a vite senza
fine
XCMK Kit di montaggio al
soffitto
XBP Otturatore in linea del tiraggio di ritorno
EFT Kit di terminazione di facile montaggio
GMK Kit per il montaggio su vetro
PDXGF Filtro antigrasso
Qui di seguito sono elencati alcuni dei ricambi disponibili. Per informazioni su come ordinarli, consultare la quarta di copertina:
41520SK Kit di fissaggio (kit
intero)
41528SK Imbocco a bicchiere circolare (intera gamma)
41731SK Motorino (DX200) 41733SK Motorino (CF20/ CF20T/DX200T)
41782SK Gruppo PCB (DX200T)
41735SK Gruppo PCB (CF20) 41736SK Gruppo PCB (CF20T) 41737SK Coperchio anteriore completo di
diaframma (DX200) 41738SK Coperchio anteriore
completo di diaframma (DX200T)
41739SK Coperchio anteriore completo di diaframma (CF20/CF20T)
41740SK Modanatura della
cornice
(intera gamma)
41741SK Gruppo cordicella (CF20/CF20T)
41742SK Girante (intera gamma)
| (Πλαστικ |
| Μέταλλ |
VK10 | Σύν |
| τ |
FD100 | Εύκαµπτ |
WDC5 | Κλιπ |
| κίνησης |
XCMK | Σύν |
| σε τα |
XBP | Φρά |
| ρεύµατ |
EFT | Σύν |
| τερµατισµ |
| εύκ |
GMK | Σύν |
PDXGF | γυαλι |
Φίλτρ | |
Πι |
|
απ |
|
Συµ |
|
τ |
|
λεπτ |
|
41520SK Σύν
(
41528SK Κυκλικ 41731SK Μ 41733SK Μ
DX200T)
41782SK Σύν 41735SK Σύν 41736SK Σύν 41737SK Μπρ συν εκτρ
41738SK Μπρ κάλυµµα συν εκτρ
41739SK Μπρ συν εκτρ
41740SK
(
41741SK Σύν τρα (CF20/CF20T)
41742SK Στρ
(
For speed and ease of Installation, your installation may require some of the Ancillaries indicated in “Ancillary Options”.
If installing on a wall (surface mounting)
1.Mark on the wall the centre of the duct hole A.
2.Use this centre to cut an opening through the wall 117mm dia, with a slight fall to the exterior.
3.Fit the wall duct (WD100), not supplied, and mortar into place.
If installing on a wall (flush mounting)
1.Mark on the wall the centre of the duct hole A, and drill a pilot hole through both walls at a slight downward angle.
2.Use the centre to mark a rectangular hole for the inner wall using the dimensions A.
3.Cut the rectangular hole through the inner wall.
4.Go outside and cut a
5.Measure the wall thickness.
Cut the wall duct (WD100), not supplied, so that it is 64mm less than the wall thickness.
If installing in a ceiling (surface mounting)
This method requires a space above the ceiling, such as a loft or attic, to provide access for 100mm internal diameter ducting.
1.Mark on the ceiling the centre of the duct hole A, avoiding ceiling joists and buried cables etc.
2.Cut a
If installing in a ceiling (flush mounting)
For 100mm diameter ducting:
1.Mark a rectangular hole using the dimensions B.
2.Cut the hole, avoiding ceiling joists and buried cables etc. For flat ducting:
• This fan can be installed within a 47mm void without the circular spigot 7 (Fig.E). Flat ducting adapter kit (FDA) available.
Preparing the fan for installation
1.Remove the front cover 2 (Fig.C)
2.Fit the foam tape !™ supplied around the circular spigot 7 (Fig.E).
3.Remove the electrical cover 5 (Fig.E). The impeller can be removed to ease access (if required). This is a
Setting the fan speed
DX200T / CF20 / CF20T Only (Fig.D)
4.The correct condensation control speed (CF20/CF20T) or operating speed
(DX200T) should be selected to suit the room size in which the fan is to be installed. Slide the switch X to the required position. Please note that the fan is factory set to “Position 2”.
5. Switch Position | Size / Room Volume (m3) |
1Large (34 and above)
2Medium (28 – 34)
3Small (less than 28)
Setting the trickle speed
DX200T / CF20 / CF20T Only (Fig.D)
6.The fan can be set so that it provides constant trickle extraction. Slide the
switch Y to the required position. Please note that the fan is factory set to “Position 0”.
7. Switch Position | Setting |
0 | Trickle extraction OFF |
I | Trickle extraction ON |
Setting the time delay start
DX200T / CF20T Only (Fig.D)
8.The fan can be set so that there is a
operation when used with an external on/off switch. Slide the switch Z to the required position. Please note that the fan is factory set to “Position 0”.
Switch Position | Setting |
0 | Time delay start OFF |
I | Time delay start ON |
Mounting the fan on a wall or ceiling (surface mounting)
1.Place the ducting into the hole and align to the required position. If wall mounting, ensure that the ducting slopes down and away from the fan
2.Mark the positions of the three fixing holes A in Fan box 6 (Fig.E).
3.If wall mounting, drill three holes 5.5mm diameter for wall plugs (supplied). If ceiling mounting B , use appropriate fasteners (not supplied).
4.Cut out the cable inlet hole, if required, in the surround 0 and slit the cable grommet. Slide the surround 0 over the fan box 6.
5.Pass the electrical cables into the fan box 6 through the rear cable inlet hole and surround, and
Ensure that cable grommet is in place and a tight fit.
6.Offer the fan box 6 up to the wall or ceiling. Ensure the circular spigot 7 enters the ducting.
7.Fix the fan box 6 to the wall using screws 8 or to the ceiling using appropriate fasteners (not supplied).
If mounting in a wall (flush mounting)
The surround 0 is not required. Fit the ducting to the circular spigot 7.
If the hole size is as recommended:
1.Assemble the three fan body clamps 9 to the fan box 6 using screws 8.
2.Slit the cable grommet. Pass the electrical cables into the fan box 6 through the cable inlet hole and cable grommet.
Ensure cable grommet is in place and a tight fit.
3.Offer the fan box 6 up to the wall.
4.Tighten up the three screws 8 until the fan is clamped to the inner wall. The fan body clamps 9 will rotate to an automatic stop position. DO NOT
OVERTIGHTEN.
If the hole size is larger than recommended i.e.: larger than the flange on the fan box 6 (Mostly relating to
1.The fan body clamps ARE NOT suitable. Construct a wooden frame of INTERNAL dimensions 203 x 233mm. Depth should be at least 50mm. Fit the