Woodstock W1823 manual Troubleshooting, Problem Possible Cause

Page 36

Model W1823 (Mfg. Since 9/10)

Troubleshooting

This section covers the most common problems and corrections with this type of machine. WARNING! DO NOT make any adjustments until power is disconnected and moving parts have come to a complete stop!

PROBLEM

 

POSSIBLE CAUSE

 

corrective action

Motor will not start.

1.

Stop button is pushed in.

1.

Rotate stop button clockwise so it pops out and is

 

 

 

 

reset.

 

2.

Remote control batteries are

2.

Replace batteries.

 

 

dead.

 

 

 

3.

Remote control frequency is

3.

Reprogram the receiver to the remote control

 

 

incorrect.

 

(Page 29).

 

4.

Power supply fuse or circuit

4.

Disconnect power, and inspect circuit for electrical

 

 

breaker has tripped.

 

shorts and repair. Replace circuit breaker if it is old

 

 

 

 

or has tripped many times.

 

5.

Contactor/transformer at fault.

5.

Test/replace contactor or transformer.

 

6.

Thermal overload has tripped.

6.

Allow motor and overload to cool, push overload

 

 

 

 

button back in. Reduce machine load/improve

 

 

 

 

motor fan air flow for better cooling.

 

7.

Start capacitor is at fault.

7.

Replace start capacitor.

 

8.

Remote control or receiver at

8.

Replace remote control or receiver.

 

 

fault.

 

 

 

9.

Motor is at fault.

9.

Replace motor.

Motor runs slower than

1.

Poor electrical connection.

1.

Inspect the power supply for loose, corroded, or

normal.

 

 

 

overheated electrical connections and repair.

 

2.

Run capacitor at fault.

2.

Replace run capacitor.

 

3.

Motor is wired incorrectly.

3.

Have the power source voltage checked and check

 

 

 

 

wiring.

 

4.

Impeller is loose on the motor

4.

Replace the motor and impeller as a set if the

 

 

shaft.

 

motor shaft or the impeller hub is damaged.

 

5.

Motor is at fault.

5.

Replace the motor.

 

 

 

 

 

Loud, repetitious noise,

1.

Dust collector is not on a flat

1.

Stabilize the dust collector.

squealing, or excessive

 

surface and wobbles.

 

 

vibration coming from dust

2.

Impeller fan is damaged and

2.

Unplug dust collector, and inspect the impeller for

collector.

 

unbalanced.

 

dents, bends, loose fins. Replace impeller if any

 

 

 

 

damage is found.

 

3.

The motor mounting is loose.

3.

Make sure all fasteners on the dust collector are

 

 

 

 

tight.

 

4.

Motor fan cover is dented, causing

4.

Replace motor fan cover.

 

 

the motor fan to hit the cover

 

 

 

 

while spinning.

 

 

 

5.

Impeller is loose on the motor

5.

Replace the motor and impeller as a set if the

 

 

shaft.

 

motor shaft or the impeller hub is damaged.

 

6.

Motor bearings at fault.

6.

Replace the motor.

 

 

 

 

 

SERVICE

-34-

Image 36
Contents OWNERS MANUAL Page Contents Introduction Woodstock Technical SupportMachine Description Controls and Features Left side viewB68=C HE886IDCH `gg`e`d\ej`fej Xikfe SAFETYJ8=KP ZXlj\XdX\kfk\dXZ`e\ip%Safety Additional Safety for Dust Collectors Circuit Requirements for 110V Prewired ElectricalCircuit Requirements Full-Load Current RatingFor 110V Connection Prewired For 220V Connection Must be RewiredGrounding Requirements Extension CordsSetup UnpackingInventory Hardware and Tool Bag Inventory Figure Qty Canister Inventory Figure QtyMachine Placement Assembly To assemble the dust collector, do these stepsSetup Vacuum tube installed Screw Collection lid installation Canister bag installed Test Run To test run the machine, do these stepsSystem Setup Collection SystemTips for Optimum Performance Duct Material Metal DuctFlexible Duct Plastic DuctSystem Grounding Flex-hose grounded to Machine Plastic BlastOperations General OperationRemote Control Operation Remote control receiver Hour Intervals BackCyclone Dust Collector Accessories Black ABS Plastic Blast Gates Aluminum Blast GatesMaintenance Normal Filter CleaningGeneral Emptying DrumService Major Filter CleaningRemote Control Reprogramming To reprogram the remote control, do these stepsElectrical Safety Instructions  HL8C@=@CKI@@8E% Due toCKI@8CIHL@IDEKJ% You Must @I&FDGFEEK8D8% DamagedWiring Diagram Stop220V Conversion To convert the Model W1823 to 220V, do these stepsMagnetic switch box Troubleshooting Problem Possible CauseOpen 1 or 2 more blast gates to different branch Parts Main Parts List DescriptionLabel Placement Model W1823 Mfg. Since 9/10 Place Stamp Here Warranty =\FjVainBVXcZhVcYIddah