TESTING THE DOOR OPERATION
When the basic wiring is complete the door operation may be tested. It may be helpful to fit an optional
Pic 28
of the Acknowledge LED. The beeper will sound at the start of each door movement and provides audible feedback during programming and door position calibration. The Beeper is fitted into the white 3- way socket at the upper left hand side of the panel market TB1 – Beeper (Pic 29).
Pic 29
A momentary press of the case lid push button or a remote push button, if fitted, operates the door.
The push button operation is: PRESS TO OPEN –
PRESS TO STOP – PRESS TO CLOSE – PRESS TO STOP. The push button may be used to switch on a light, if fitted, when the door is closed and without moving the door, by an extended press of the push button for 2 1/2 seconds until the light illuminates.
Note the factory set positions of each of the DIP switches at the top right hand side of the panel will be: (Pic 30)
Pic 30
SW1 | SAFETY MODE | OFF/N/C |
SW2 | STANDARD SAFETY | OFF |
SW3 | 12V | OFF |
SW4 | OFF (NOT USED) | |
SW5 | INTERLOCK | ON |
SW6 | LIGHTING MODE | OFF |
SW7 | MOTOR POLARITY | AS REQUIRED |
| (See next paragraph) | |
SW8 | STOP BUTTON | ON |
| (A separate Stop button is not fitted). |
Plug the power cord into the convenient power supply socket and switch on the mains power. Note that the power indicator LD3 is illuminated.
(Pic 31)
Pic 31
11