Adjustments Continued . . .
❒Loosen the wing screws, estimate the direction to aim the sensor and tighten the wing screws just enough to hold the sensor in place.
❒Walk through the coverage area noting where you are when the lights turn on. Loosen the wing screws and readjust the sensor as necessary. Tighten the wing screws (finger tight) when you are satisfied with the coverage direction. If you have not already tightened the locknut against the base plate, do so now. Keep the sensor at least 1 inch (25 mm) from lamps and keep the controls on the bottom.
❒Adjust SENSITIVITY as needed to increase or decrease the range. Too much sensitivity may increase false triggering.
❒Set the amount of TIME (1, 5 or 20 minutes) you want the lights to stay on after motion is detected at night.
❒If you need to detect objects more than 70 feet (21 m) away, turn Range Boost on.
❒Replace the rubber cover to protect controls.
Aim Sensor Down for Short Coverage
Aim Sensor Out for
Long Coverage
Expected Coverage
The sensor is less sensitive to motion directly towards it, most sensitive to motion across its field of view.
When mounted 8 feet (2.4 m) from the ground, you may expect the range shown below. If mounted much higher the sensor may miss ob- jects near the ground. If mounted much lower the sensor range may be reduced.
MotionMotion
Maximum Range
Sensor
Least Sensitive | Most Sensitive |
8 ft.
(2.4 m)
70 ft. | 100 ft. (30.5 m) |
(21 m) | Boosted |