Lindy Carbon Monoxide Alarm user manual Snmp Configuration, Ame, Snmp a Ccess, Write Community

Page 24

OOPERATIONPERATION

4.5.1

(SNMP CONFIGURATION)

 

 

 

 

 

 

Complete control of the RMS via

 

 

 

SNMP with alarm (trap function)

LINDY

 

 

and support of separate

LINDY Rack Monitoring System

 

communities for read and write

see www.lindy.com

 

 

 

 

 

operations.

 

 

 

SNMP V1 in accordance with RFC

 

 

 

1213 is implemented. MIB-II

 

 

 

including RMS private MIB is

 

 

 

supported.

 

 

 

The complete MIB file of the RMS

 

 

 

is on the supplied CD-ROM.

 

 

 

Explanation of the MIB variables

 

 

 

> A3.

 

 

 

Visualised integration in manage-

[N] NAME

[S] SEND AUTHTRAPS

 

ment platforms on request.

Administrative name of the device.

Send trap with unauthorised

 

 

For example: “RMS”

access with invalid or incorrect

 

 

[L] LOCATION

Community String (authority trap)..

 

 

[M] SNMP ACCESS

 

 

Description of the location of the

 

 

device.

Enable or disable access via SNMP.

 

 

[C] CONTACT

– Trap Destinations –

 

 

List of a maximum of 8 IP

 

 

Name of the person responsible

 

 

addresses to which SNMP traps

 

 

for this device and contact infor-

 

 

are sent.

 

 

mation. For example:

 

 

 

 

 

“LINDY support,

[A] ADD NEW TRAP DESTINATION

 

 

Tel. +49 (0) 621 / 47 005 - 0”

 

 

Add an IP address to the list of

 

 

 

 

 

[R] READ COMMUNITY

trap receivers..

 

 

Name of the community with the

[D] DELETE TRAP DESTINATION

 

 

right to read SNMP variables.

 

 

For example: “public”

Delete IP address from the list of

 

 

[W] WRITE COMMUNITY

trap receivers.

 

 

 

 

 

Name of the SNMP community

[?] HELP

 

 

with the right to write SNMP

 

 

Explanation of the menu items.

 

 

variables.

 

 

 

 

 

For example: “private”

[Q] QUIT WITHOUT SAVING

 

 

 

 

 

[T] TRAP COMMUNITY

Jump back to the “Network

 

 

Name of the SNMP community

Configuration” menu without

 

 

with the right to receive traps from

saving changes..

 

 

this device.

[RETURN] QUIT WITH SAVING

 

 

For example: “alarm”

 

 

 

Jump back to the “Network

 

 

 

Configuration” menu and save

 

 

 

changes

Rack

Image 24
Contents MonitoringRack MonitoringSystemSystem Rack Ccontentsontents Ccontentsontents General Information Safe WorkingWarranty Lapse of warrantyDisposal Service HotlineMail STANDARDS, RegulationsRack Monitoring LiteConnection options DigitalHumidity Sensor digitalMains Power Strips Door ContactReader Infrared Room surveillancePreparations Check the supplied itemsNecessary Tools Installation and Commissioning Electrical Installation Connections and cablingCabling Mains montoringDigital AlertUPS 10BASETCOM AUXFuses Double -pole fuse / fuse of the neutral wire Fuse for the auxiliary voltageSupply CommissioningOperator Control Elements Initial StateOperation VIA Keys on the Front of the Device Selecting a menu itemFilter messages Display in the Confirm menuEntering network parameters Operation VIA Telnet or Serial Interface COM? Help Block diagram Network Configuration IP AddressSnmp Configuration AMESnmp a Ccess Write CommunityReboot Configuration VIA Tftp Update VIA TftpTFTP-SERVER StatusUser Administration Selection pointer to next userConfigure digital outputs Digital Outputs InvertTemperature Inputs Digital InputsQuit Humidity Inputs Mains MonitoringUpdate the screen AUX Device Selection Previous Device+ Next Device Return Quit With SavingFilter Filter Selection UITSnmp Trap FfectLED W Arning DIGITAL/ALERT/UPS Inputs TEMPERATURE/MAINS/HUMIDITY Inputs ODE-A B M ODE-BSet threshold Selection pointer to next input Feedback Inputs Previous Feedback InputIlter Message LOG Preconfigured filters with an Example of filter configuration using filter 1 temperatureExamples of filter settings Example of terminal assignMonitoringRack MonitoringSystemSystem Rack Eexamplexample Configurationconfiguration Specimen output ConfigurationRack Mmalfunctionsalfunctions RemedyTechnicaltechnical Datadata Rated ambient temperatureFAQ EMCMIB RFCProduct designation ModelSystem Configuration DocumentationExplanation of the MIB For RMSIso.org.dod.internet.private.enterprises.infratec.rms Variable Type ValueObjects under Variable Type Value Access Object under ups I NT Able Variable Type Value AccessObjects under Variable Type Value Objects under outputTable Variable Type Value Objects underObjects under tempTable Objects under humidTableObjects under mainsTable Variable Type Value Objects under filterTable Variable Type ValueObjects under Variable Variable Type Value Access 6.1.4.1.1909.10.7.3Type Value Access FilterMainsTableObjects under userTable Variable Type Value Objects under aux VariableObjects under icc Variable Type Value GNU General Public RemoRack RMS Lite RMS AdvancedRack