Lindy Carbon Monoxide Alarm user manual Explanation of the MIB, For RMS, Variable Type Value

Page 50

AAPPENDICESPPENDICES

A3

EXPLANATION OF THE MIB

The RMS can be accessed under the OID 1.3.6.1.4.1.1909. 10

FOR RMS

(iso.org.dod.internet.private.enterprises.infratec.rms)

 

10rms

Structure of the MIB

rmssystem

The complete MIB in ASN.1-

1

Notation is on the enclosed

2

input

CDROM as the file “RMS MIB”

 

1 digitalInTable

 

2alertInTable

3upsInTable 3 output

1outputTable

2outputLogicTable 4 temp

1tempTable 5 humid

1humidTable 6 mains

1mainsTable 7 filter

1filterTable

2filterDigitalInTable

3filterAlertInTable

4filterUPSINTable

5filterTempTable

6filterHumidityTable

7filterMainsTable

8filterFeedbackTable 8 message

1messageTable 9 user

1userTable 20 aux

Key to the following Tables:

21 icc

 

 

 

 

INT

Integer

 

 

 

 

 

CNT

Counter

 

 

 

 

 

DS

Display String

 

 

 

 

 

OS

Octet String

 

 

 

 

 

TT

TimeTicks

 

 

 

 

 

RO

Read Only

 

 

 

 

 

RW

Read Write

 

 

 

 

 

 

 

Variable

Type

Value

Access

Objects under RMS system

1 systemVersion

DS

 

 

RO

(1.3.6.1.4.1.1909.10.1)

{ default (1),

 

 

 

2 systemSNMPsave

INT

 

RW

for example

3 systemMsgToSyslog

 

save (2) }

 

 

INT

{ msglog-off (1)

RO

Reset RMS

1.3.6.1.4.1.1909.10.1.4.0 := 1

4 systemReset

 

msglog-on (2) }

 

INT

{ default (1),

 

RW

 

 

 

 

 

5 systemSNMPaccess

 

reset (2) }

 

 

 

 

INT

{ readonly (1),

 

RO

 

 

 

 

readwrite (2) }

 

 

Rack

Image 50
Contents MonitoringRack MonitoringSystemSystem Rack Ccontentsontents Ccontentsontents General Information Safe WorkingDisposal WarrantyLapse of warranty Mail ServiceHotline STANDARDS, RegulationsRack Monitoring LiteHumidity Connection optionsDigital Sensor digitalReader Mains Power StripsDoor Contact Infrared Room surveillanceNecessary Tools PreparationsCheck the supplied items Installation and Commissioning Cabling Electrical InstallationConnections and cabling Mains montoringUPS DigitalAlert 10BASETCOM AUXSupply Fuses Double -pole fuse / fuse of the neutral wireFuse for the auxiliary voltage CommissioningOperator Control Elements Initial StateOperation VIA Keys on the Front of the Device Selecting a menu itemEntering network parameters Filter messagesDisplay in the Confirm menu Operation VIA Telnet or Serial Interface COM? Help Block diagram Network Configuration IP AddressSnmp a Ccess Snmp ConfigurationAME Write CommunityReboot TFTP-SERVER Configuration VIA TftpUpdate VIA Tftp StatusUser Administration Selection pointer to next userConfigure digital outputs Digital Outputs InvertQuit Temperature InputsDigital Inputs Humidity Inputs Mains MonitoringUpdate the screen + Next Device AUX Device SelectionPrevious Device Return Quit With SavingFilter Snmp Trap Filter SelectionUIT FfectLED W Arning DIGITAL/ALERT/UPS Inputs Set threshold Selection pointer to next input TEMPERATURE/MAINS/HUMIDITY InputsODE-A B M ODE-B Ilter Feedback InputsPrevious Feedback Input Message LOG Examples of filter settings Preconfigured filters with anExample of filter configuration using filter 1 temperature Example of terminal assignMonitoringRack MonitoringSystemSystem Rack Eexamplexample Configurationconfiguration Specimen output ConfigurationRack Mmalfunctionsalfunctions RemedyTechnicaltechnical Datadata Rated ambient temperatureMIB FAQEMC RFCProduct designation ModelSystem Configuration DocumentationIso.org.dod.internet.private.enterprises.infratec.rms Explanation of the MIBFor RMS Variable Type ValueObjects under Variable Type Value Objects under Variable Type Value AccessObject under ups I NT Able Variable Type Value Access Objects under tempTable Objects under outputTable Variable Type ValueObjects under Objects under humidTableObjects under Variable Objects under mainsTable Variable Type ValueObjects under filterTable Variable Type Value Variable Type Value Access 6.1.4.1.1909.10.7.3Type Value Access FilterMainsTableObjects under icc Variable Type Value Objects under userTable Variable Type ValueObjects under aux Variable GNU General Public RemoRack RMS Lite RMS AdvancedRack