Note:

Keep the anti-static bag for future use. You

 

might need the original bag to store the card if

 

you have to remove the card from a PC or trans-

 

port it elsewhere.

2.2 Driver Installation

We recommend you install the driver before you install the PCI- 1718HDU/HGU card into your system, since this will guarantee a smooth installation process.

The Advantech Device Drivers Setup program for the PCI-1718HDU/ HGU card is included in the companion CD-ROM that is shipped with your DA&C card package. Please follow the steps below to install the driver software:

1.Insert the companion CD-ROM into your CD-ROM drive.

2.The Setup program will be launched automatically if you have the autoplay function enabled on your system. When the Setup Pro- gram is launched, you will see the following Setup Screen.

Note:

If the autoplay function is not enabled on

 

your computer, use Windows Explorer or

 

Windows Run command to execute

 

SETUP.EXE on the companion CD-ROM.

13

Chapter2

Image 21
Contents Bit Multifunction Cards with Universal PCI Bus PCI-1718 SeriesCopyright Acknowledgements Product Warranty 2 years Safety Precaution Static Electricity Technical Support and AssistancePacking List Contents Appendix Specifications Appendix D Calibration Viii Introduction PCI-1718HDU/HGU is register-level- pro Features PCI-Bus Plug & PlayAutomatic Channel/Gain Scanning BoardID Switch Onboard Programmable Timer/CounterApplications Onboard FifoInstallation Guide Installation Flow Chart Programming choices for DA&C cards Software OverviewDevice Drivers Register-level ProgrammingProgramming Tools Device Driver Programming RoadmapProgramming with Device Drivers Function Library Troubleshooting Device Drivers ErrorWiring Cables PCL-10120 AccessoriesWiring Boards PCL-10137Installation Unpacking SETUP.EXE on the companion CD-ROM Driver InstallationSetup Screen of Advantech Automation Software Installation Hardware InstallationSetting Up the Device Device Setup & ConfigurationDevice Setting Dialog Box Configuring the DeviceTest Utility Dialog Box Signal Connections Overview Switch and Jumper SettingsBoard ID Setting SW1 Setting the BoardID Switch SW1Summary of Switch SW2 Settings Channel Configuration, S/E or Diff SW2Summary of Jumper JP11 Settings 3 D/A Reference Voltage, int./ext. JP11Internal Voltage Reference, -10 V or -5 V JP10 Summary of Jumper JP10 SettingsSummary of Jumper JP8 Settings Timer Clock Selection JP8Digital Output, 20-pin or 37-pin Connector JP1 Summary of Jumper Settings6 Ext. trigger and Counter Gate 0 Control JP5 JP1 first JP21 Jumper Settings Setting the Time to Reset Digital OutputsPin Assignment Signal ConnectionsI/O Connector Signal Descriptions 1 I/O Connector Signal DescriptionAnalog Input Connections Single-ended Channel ConnectionsDifferential Channel Connections Incorrect Connection Correct ConnectionExpanding Analog Inputs Analog Output Connections Analog Output ConnectionGND D.GND Digital Signal ConnectionsField Wiring Considerations Page Programming Guide Register Programming Programming with the DriverEOC=0 Software Trigger and PollingExample Code ISR Pacer Trigger Mode with InterruptExample Code Page Enable Pacer Trigger Mode with Interrupt and Fifo Add you code here Clear System Interrupt*****/ Add you code here Add your code here Programming with LabVIEW and ActiveDAQ LabViewActiveDAQ Page Specifications Analog Input Appendix a SpecificationsDigital Input Analog OutputDigital Output Counter/TimerGeneral Page Block Diagrams Appendix B Block Diagrams Register Structure & Format I/O Port Address Map Appendix C Register Structure & FormatTable C.1 PCI-1718HDU/HGU Register Format Part Table C.2 PCI-1718HDU/HGU Register Format Part Table C.3 PCI-1718HDU/HGU Register Format Part A/D Data and Channels BASE+00H~01H Software A/D Trigger BASE+00HTable C.5 Register for Software A/D Trigger PCI-1718HDU A/D Range Control BASE+01HG3 and G2 are not used for PCL-818L MUX Scan Channel Control BASE+02H Table C.7 Register for MUX Scan Channel ControlProgramming example for PCI-1718HDU Digital I/O Registers Base + 03/0BH MUX Scan Channel Status BASE+02HTable C.8 Register for MUX Scan Channel Status Table C.9 Register for Digital OutputD/A Output BASE+04/05H Table C.10 Register for Digital OutputTable C.11 Register for D/A Output Table C.12 Register for Fifo Interrupt Control Fifo Interrupt Control BASE+06H12 A/D Status BASE+08H Clear Interrupt Request BASE+08HTable C.13 Register for Clear Interrupt Request Table C.14 Register for A/D StatusMUX Table C.15 Register for A/D Control 13 A/D Control BASE+09HTimer/Counter Enable BASE+0AH Programmable Timer/Counter BASE+0C~0FHTable C.16 Register for Timer/Counter Enable 17 A/D Data and Channel from Fifo Base + 17/18H Clear Fifo Interrupt Request BASE+14HTable C.17 Register for Clear Fifo Interrupt Request Table C.18 Register for A/D Data and Channel from FifoFifo Clear BASE+19H Fifo Status BASE+19HTable C.19 Register for Fifo Status Table C.20 Register for Fifo ClearSoftware Trigger Mode with Polling Register Programming Flow ChartPacer Trigger Mode with Interrupt Pacer Trigger Mode with Interrupt Fifo Used Page Calibration Appendix D Calibration Figure D.1 PCI-1718 VR Assignment VR AssignmentOutputs is recommended A/D CalibrationD/A Calibration

PCI-1718 Series specifications

The Advantech PCI-1718 Series represents a robust solution in the realm of data acquisition and control, designed to meet the demands of various industrial applications. This series is a prominent choice for engineers and system integrators looking to implement effective data monitoring and analysis in real-time conditions.

One of the notable features of the PCI-1718 series is its ability to handle multi-channel data acquisition, supporting up to 16 analog input channels. This capability allows for the simultaneous recording of multiple signals, which is critical in applications requiring comprehensive data analysis and monitoring. The device presents a sampling rate of up to 200 kHz, ensuring that even fast-changing signals are recorded with high fidelity.

The PCI-1718 Series also integrates 16-bit resolution for analog inputs, delivering precision that is essential for high-quality measurements. This level of resolution is particularly beneficial in industries such as medical instrumentation and scientific research, where the accuracy of data can significantly impact outcomes. Additionally, the device supports various input types, including voltage and current signals, making it adaptable to multiple sensing solutions.

In terms of connectivity, the PCI-1718 series is compatible with an array of I/O modules, enhancing its versatility. It supports both differential and single-ended input configurations, allowing users to select the most suitable measurement technique for their applications.

The series boasts built-in support for digital I/O and counters, facilitating the integration of control signals alongside data acquisition tasks. With 8 digital input lines and 8 digital output lines, the device allows for straightforward control over peripheral devices.

Advantech equipped the PCI-1718 with comprehensive software support, including drivers for popular programming environments, such as Visual Studio, LabVIEW, and MATLAB. This broad compatibility ensures that users can easily implement the hardware in their preferred software environments.

Another critical characteristic of the PCI-1718 Series is its robust design, featuring a low-profile PCI form factor that makes it suitable for various computer systems without compromising on performance. Its stable operation under fluctuating environmental conditions is facilitated through advanced engineering and high-quality components.

In conclusion, the Advantech PCI-1718 Series stands out with its multi-channel capabilities, high precision, extensive connectivity options, and solid software support. These features make it an exceptional choice for professionals in need of a reliable data acquisition system that can handle diverse and demanding applications efficiently.