Heat Controller BHD-301-G, BHD-501-G, BHD-651-G Operating Conditions, Turning the Unit on or OFF

Page 5

Heat Controller, Inc.

Portable Dehumidifier with R-410A

BHD-G Service Manual

 

 

 

2. Product Installation Instructions

Install the portable dehumidifier in a flat and spacious location where the air outlets will not be obstructed. Do not install underneath desks or inside cupboards as this will restrict the air flow.

16in (40cm) or more

Maintain a clearance of at least 8 inches (20cm) in the front and rear of the unit to maintain correct air-flow.

3. Product Operation

 

 

8in (20cm) or

8in (20cm) or more

 

more

3.1 OPERATING CONDITIONS:

This unit is designed to operate in an environment between 41°F-90°F (5°C and

 

 

 

8in (20cm) or more

 

 

 

8in (20cm) or more

35°C).

 

 

 

 

 

 

 

 

 

If the unit has been switched off and needs to be switched on again quickly, allow approximately three minutes for the compressor to start up and for dehumidifaction to resume.

Do not connect the dehumidifier to a multiple socket outlet, which is also being used for other electrical appliances. Select a suitable location, making sure you have easy access to an electrical outlet.

Plug the unit into a 115V~60Hz electrical socket-outlet with a ground connection.

Make sure the Water Tank is correctly inserted otherwise the unit will not operate properly.

3.2TURNING THE UNIT “ON” OR “OFF”

3.2.1Plug the cord to the proper power recepticable. The unit’s program will run a self-check, if it is normal, the power indicator flashes (at 0.5Hz). Press Power button now, the unit will start operating under DEHUMIDIFYING mode with 60% setting humidity. Press the Humidity (+) or (-) button will change humidity setting.

3.2.2Press Continuous button to start the continous dehumidification mode. During this mode, the Humidity (+) or (-) button are disabled.

3.2.3Press the Power button to turn off the unit.(You do not need to unplug the power cord except when the unit will not be in use for a long period of time.)

3.3OPERATION WITH WATER TANK

Water will drain into the tank. When the tank is full, the unit stops operating, the water Full indicator light will flash. Do not remove the water tank while the machine is still working wait for the unit to completely stop to remove the bucket.

If not, some water may drip.

To empty the water tank, remove the tank as shown, empty the water and replace the tank back in the unit. Ensure components of water tank are correctly positioned.

The unit will re-start when the water tank is restored to its correct position.

1.Pull out the bucket a little.

2. Hold both sides of the

3. Pour the water out

bucket with even strength,

 

and pull it all the way out

 

from the unit.

 

4

Image 5
Contents Portable Dehumidifer Series With R-410A Table of Contents Unit Features Safety PrecautionsInsulation Resistance Test Control LocationsTimer Set Control TimerOutside Dimensions Operation with Water Tank Operating ConditionsTurning the Unit on or OFF Operation with Continuous Drainage MaintenanceSetting the Relative Humidity Powering on the UnitContinuous Dehumidification Mode Powering OFF the UnitCompressor Winding Test Defective CompressorGround Test Checking Compressor EfficiencySealed Refrigeration System Repairs Hermetic Component ReplacementChecking the Internal Overload Equipment RequiredCapacitor FAN MotorCapacitor Test Identify ALL Possible PCB Fault Codes Troubleshooting GuideTrouble Shooting Room Airconditioner Voltage LimitsHumidity sensor check Fail to start or fail to start motor Complaint Cause Remedy Abnormal noisePortable Dehumidifier with R-410A Complaint Cause Remedy Wiring Diagram 05/2010

BHD-301-G, BHD-651-G, BHD-501-G specifications

The Heat Controller BHD series, comprising models BHD-651-G, BHD-301-G, and BHD-501-G, is designed to meet diverse heating needs with efficiency and reliability. Each model incorporates advanced features and technologies that enhance user experience, making them ideal for both home and commercial use.

Starting with the BHD-651-G, this model is a powerhouse, offering significantly higher output capacity suitable for larger spaces. It boasts an intelligent thermostat that ensures precise temperature control, allowing users to maintain their preferred environment effortlessly. The BHD-651-G employs a dual heating technology, combining convection and radiant heat for balanced warmth. Additionally, its energy-saving mode optimizes power consumption without sacrificing comfort, making it an eco-friendly choice.

The BHD-301-G is designed for medium-sized areas, striking a perfect balance between power and portability. Featuring a sleek design, it is lightweight and easy to move around. One of its standout features is the programmable timer, allowing users to set heating schedules that align with their lifestyles. This model also includes a filter system that cleans and purifies the air while heating, ensuring a healthier indoor environment. Moreover, the BHD-301-G operates quietly, making it ideal for use in bedrooms or offices.

Finally, the BHD-501-G caters to a variety of settings where flexibility is crucial. This model is equipped with multi-directional airflow, enabling users to direct heat where it is most needed. The BHD-501-G also features an advanced safety system, including overheat protection and a tip-over switch, ensuring peace of mind during use. Its user-friendly interface with intuitive controls simplifies operation, allowing for effortless adjustments to temperature and settings.

In summary, the Heat Controller BHD series offers a comprehensive range of features designed to provide efficient heating solutions tailored to different environments. With technologies aimed at enhancing power efficiency, air quality, and user comfort, the BHD-651-G, BHD-301-G, and BHD-501-G models stand out as top choices for reliable heat management. Their innovative characteristics ensure that users can enjoy warmth and comfort in any setting while being mindful of energy consumption and safety.