Heat & Glo LifeStyle PIER-36TRLP-IPI, PIER-36TR-IPI Getting Started, Typical Appliance System

Page 16

4

Getting Started

Installer Guide

 

 

 

A. Typical Appliance System

NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual

HORIZONTAL

TERMINATION CAP (SECTION 10.M )

FRAMING/HEADER (SECTION 5.B)

Note: Dual venting configurations ARE NOT allowed. Appliance MUST be vented EITHER vertically OR horizontally.

NON-COMBUSTIBLE ROOF FLASHING

MAINTAINS MINIMUM CLEARANCE

AROUND PIPE (SECTION 10.G)

VERTICAL TERMINATION CAP (SECTION 10.J)

STORM COLLAR (SECTION 10.H)

VENT PIPE PENETRATES ROOF

PREFERABLY WITHOUT AFFECTING

ROOF RAFTERS (SECTION 8.C )

ATTIC INSULATION SHIELD (NOT

SHOWN) MUST BE USED HERE

TO KEEP INSULATION AWAY

FROM VENT PIPE IF ATTIC IS

INSULATED (SECTION 8.D )

VENT PIPE (SECTION 9 and 10)

FRAMING HEADED OFF

IN CEILING JOISTS

(SECTION 8.C)

CEILING FIRESTOP

ON FLOOR OF ATTIC (SECTION 8.C)

WALL SWITCH

SECTION 12.E.

GAS LINE

(SECTION 11.C)

HEARTH EXTENSION

SURROUND

MANTEL AND MANTEL LEG (SECTION 5.D)

Figure 4.1 Typical System

16

Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI2176-900 Rev. F • 8/11

Image 16
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference Materials B. Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Blower Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Blower Kit optionalLighting Instructions IPI Final inspection byFrequently Asked Questions After Fireplace is LitMaintenance and Service Ember Light Replacement Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesPIER-36TR-IPI Mantel and Wall Projections See-Through Combustible Mantel Pier Combustible MantelSee-Through Non-Combustible Mantel Pier Non-Combustible MantelTOP View Termination Locations Vent Termination Minimum Clearances= AIR Supply Inlet = Area Where Terminal is not Permitted Covered Alcove ApplicationsTo Install the Heat Shield Install Support BracketsContinue Adding Vent Components Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsTo SLP series vent pipe, if desired Vent DiagramsTop Vent Horizontal Termination V1 Minimum H1 Maximum Top Vent Horizontal Termination One Elbow Two ElbowsMinimum + H 2 Maximum Top Vent Horizontal Termination Three Elbows Exhaust restrictor Instructions Break Here Two Elbows Three Elbows Maximum + V 2 MinimumPage Rear Vent Horizontal Termination Two Elbows H1 Maximum V1 Minimum H2 Maximum H1+ H2 MaximumRear Vent Vertical Termination One Elbow Minimum + H 2 MaximumRear Vent Vertical Termination Three Elbows H1 Maximum V1 Minimum H1+ H2 MaximumVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Pipe DVP SLPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Top Vent Appliance PreparationProceed to . C Rear Vent Cut the metal retaining bandSecuring and Leveling the Appliance Securing An ApplianceInstalling Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe Sections DVP Pipe OnlyAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe DVP-HPC1 DVP-HPC2Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Junction Box InstallationIntelliFire Ignition System Wiring Electrical Service and RepairWSK-MLT Multifunction Wall Switch PrecautionsWiring the Wall Switch Install the Flame Solenoid Connect the Temperature Sensor Switch for Fan optionalWall Switch Button Operation Setting Flame Height/Manifold PressureWSK-MLT Operating Instructions Up and Down Arrows Finishing To install the Splatter GuardSplatter Guard To Close the Lower Access Panel To Remove the Splatter Guard12 Minimum Vertical and Maximum Horizontal 17 Noncombustible Facing Diagram Facing MaterialFinishing Material ST-36TR-IPI22 Pier Door Finishing Elevated Hearth Systems Appliance Setup Placement of Embers Placing the Ember MaterialInstall the Log Assembly Inch5 4 Notch Notch engaged with grate tineInstall Trim Kits and Surrounds Air Shutter SettingSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System Sure specifications. Polish flame-sensing rod with fine steel Appliance Dimension Diagram Reference MaterialsElectrical Access GAS Line Left View Front View Right View Vent Components Diagrams DVP-AS2DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M DVP-TV Optional Wire Harness DVP-HRC-SSElbow 660 mmExtended Heat Shield Ceiling FirestopWall Thimble-Black Black Support Box-BlackAdapter Service Parts Log Set AssemblyAt Depot See-Through Gas FireplaceStocked Pier Direct Vent Fireplace#17 Valve Assembly PIER-36TR, ST-36TR-IPIService Parts List ST-36TR-IPI, PIER-36TR-IPIContact Information

PIER-36TR-IPI, PIER-36TRLP-IPI, ST-36TRLP-IPI, ST-36TR-IPI specifications

Heat & Glo is renowned for its innovative and stylish fireplace solutions, and their LifeStyle series is no exception. The LifeStyle models, including the PIER-36TRLP-IPI, PIER-36TR-IPI, ST-36TRLP-IPI, and ST-36TR-IPI, are designed to provide both aesthetic appeal and unparalleled heating performance, making them perfect for a variety of living spaces.

One of the defining features of these units is their contemporary design, which integrates seamlessly into modern interiors. The sleek, linear appearance allows for versatile installation options, whether in a wall or as a standalone feature. With a focus on maximizing visual impact, the large glass viewing area provides an unobstructed view of the flames, creating an inviting ambiance.

In terms of technology, these fireplaces are equipped with advanced ignition systems, specifically the IntelliFire® ignition system, which intelligently manages flame levels and optimizes efficiency. This technology not only aids in ease of use but also enhances safety, reducing the risk of unintended ignition.

The LifeStyle series also emphasizes energy efficiency. With an emphasis on reducing environmental impact, these fireplaces boast high efficiency ratings, ensuring that homeowners enjoy warmth without excessive energy consumption. The incorporation of direct vent technology allows for better heat retention indoors while drawing in fresh air from outside, minimizing drafts.

When it comes to performance, the LifeStyle models deliver reliable heating capabilities. Each unit is capable of producing up to 36,000 BTUs, ensuring sufficient warmth for medium to large spaces. This output, combined with adjustable flame height and ember bed options, allows users to customize their heating experience according to personal preferences.

Another characteristic of the LifeStyle series is the extensive range of aesthetically pleasing decorative options. Owners can select from various media, such as glass or ceramic logs, which add a touch of style to the fireplace while complementing the overall decor of the room.

Finally, easy maintenance is a hallmark of the LifeStyle series. Many components are designed for straightforward accessibility, making routine upkeep simple and hassle-free. This attention to practicality ensures that homeowners can enjoy their fireplace without the burden of complicated maintenance routines.

In summary, the Heat & Glo LifeStyle PIER and ST series combines elegant design, advanced technology, and efficient heating, making them a sought-after choice for homeowners looking to enhance their living spaces with a modern fireplace solution.