Heat & Glo LifeStyle PIER-36TRLP-IPI, PIER-36TR-IPI, ST-36TRLP-IPI Covered Alcove Applications

Page 24

C

V

J

B

 

 

 

B

 

 

V

B

 

V

 

D

 

V

 

V

A

F

G

M

V

H or i

X V H

V H V

E

V

A

O

N

P

R

Q

 

 

 

 

V

 

 

 

 

 

 

 

 

L

 

 

 

 

 

K

 

 

 

 

K

 

 

 

 

 

Electrical

 

 

 

V

 

 

 

 

V

 

 

 

 

 

 

V= VENT TERMINAL

Service

X= AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

A

=

12 inches

clearances above grade, veranda,

 

 

 

porch, deck or balcony

B

=

12 inches

clearance to window or door that may

 

 

 

be opened, or to permanently closed

 

 

 

window

C

=

18 inches

clearance below unventilated soffit

 

 

18 inches

clearance below ventilated soffit

 

 

30 inches

clearance below vinyl soffits and

 

 

 

electrical service

D

=

9 inches

clearance to outside corner

E

=

6 inches

clearance to inside corner

F

=

3 ft. (Canada)

not to be installed above a gas me-

 

 

 

ter/regulator assembly within 3 feet

 

 

 

horizontally from the center-line of the

 

 

 

regulator

G

=

3 ft

clearance to gas service regulator

 

 

 

vent outlet

H

=

9 inches (U.S.A)

 

12inches (Canada) .clearance to non-mechanical (unpow- ered) air supply inlet, combustion air inlet or direct-vent termination

i= 3 ft. (U.S.A.)

6 ft. (Canada)

...........clearance to a mechanical (powered)

 

air supply inlet

All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below termination.

J

= 7 ft

On public property: clearance above

 

 

paved sidewalk or a paved driveway.

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

C

V

Covered Alcove Applications

(Spaces open only on one side and with an overhang)

N= 6 inches ........... non-vinyl sidewalls 12 inches ......... vinyl sidewalls

O= 18 inches ......... non-vinyl soffit and overhang 42 inches ......... vinyl soffit and overhang

P= 8 ft.

 

QMIN

RMAX

1 cap

3 feet

2 x Q ACTUAL

2 caps

6 feet

1 x Q ACTUAL

3 caps

9 feet

2/3 x Q ACTUAL

4 caps

12 feet

1/2 x Q ACTUAL

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

Measure vertical clearances from this surface.

Measure horizontal clearances from this surface.

K

=

6 inches

clearance from sides of electrical

 

 

 

service

L

=

12 inches

clearance above electrical service

Location of the vent termination must not interfere with access to the electrical service.

M = 18 inches

clearanceunderveranda,porch,deck,

 

balcony or overhang

42 inches

vinyl or composite overhang

Permitted when veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor.

Figure 6.3 Minimum Clearances for Termination

CAUTION! Risk of Burns! Termination caps are HOT, consider proximity to doors, traffic areas or where people may pass or gather (sidewalk, deck, patio, etc.). Listed cap shields available. Contact your dealer.

Local codes or regulations may require different clearances.

Vent system termination is NOT permitted in screened porches.

Vent system termination is permitted in porch areas with two or more sides open.

Hearth & Home Technologies assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Vinyl protection kits are suggested for use with vinyl siding.

24

Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI2176-900 Rev. F • 8/11

Image 24
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference Materials B. Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Blower Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Blower Kit optionalLighting Instructions IPI Final inspection byFrequently Asked Questions After Fireplace is LitMaintenance and Service Ember Light Replacement Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesPIER-36TR-IPI Mantel and Wall Projections See-Through Combustible Mantel Pier Combustible MantelSee-Through Non-Combustible Mantel Pier Non-Combustible MantelTOP View Termination Locations Vent Termination Minimum Clearances= AIR Supply Inlet = Area Where Terminal is not Permitted Covered Alcove ApplicationsInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams To SLP series vent pipe, if desiredTop Vent Horizontal Termination Top Vent Horizontal Termination One Elbow Two Elbows V1 Minimum H1 MaximumMinimum + H 2 Maximum Top Vent Horizontal Termination Three Elbows Exhaust restrictor Instructions Break Here Two Elbows Three Elbows Maximum + V 2 MinimumPage Rear Vent Horizontal Termination Two Elbows H1 Maximum V1 Minimum H2 Maximum H1+ H2 MaximumRear Vent Vertical Termination One Elbow Minimum + H 2 MaximumRear Vent Vertical Termination Three Elbows H1 Maximum V1 Minimum H1+ H2 MaximumVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Pipe DVP SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Rear Vent Cut the metal retaining bandSecuring and Leveling the Appliance Securing An ApplianceInstalling Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe Sections DVP Pipe OnlyAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe DVP-HPC1 DVP-HPC2Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Junction Box InstallationIntelliFire Ignition System Wiring Electrical Service and RepairWSK-MLT Multifunction Wall Switch PrecautionsWiring the Wall Switch Install the Flame Solenoid Connect the Temperature Sensor Switch for Fan optionalSetting Flame Height/Manifold Pressure Wall Switch Button OperationWSK-MLT Operating Instructions Up and Down Arrows To install the Splatter Guard FinishingSplatter Guard To Close the Lower Access Panel To Remove the Splatter Guard12 Minimum Vertical and Maximum Horizontal 17 Noncombustible Facing Diagram Facing MaterialFinishing Material ST-36TR-IPI22 Pier Door Finishing Elevated Hearth Systems Appliance Setup Placement of Embers Placing the Ember MaterialInstall the Log Assembly Inch5 4 Notch Notch engaged with grate tineInstall Trim Kits and Surrounds Air Shutter SettingTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Sure specifications. Polish flame-sensing rod with fine steel Appliance Dimension Diagram Reference MaterialsElectrical Access GAS Line Left View Front View Right View Vent Components Diagrams DVP-AS2DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M DVP-TV Optional Wire Harness DVP-HRC-SSElbow 660 mmExtended Heat Shield Ceiling FirestopBlack Support Box-Black Wall Thimble-BlackAdapter Service Parts Log Set AssemblyAt Depot See-Through Gas FireplaceStocked Pier Direct Vent Fireplace#17 Valve Assembly PIER-36TR, ST-36TR-IPIService Parts List ST-36TR-IPI, PIER-36TR-IPIContact Information

PIER-36TR-IPI, PIER-36TRLP-IPI, ST-36TRLP-IPI, ST-36TR-IPI specifications

Heat & Glo is renowned for its innovative and stylish fireplace solutions, and their LifeStyle series is no exception. The LifeStyle models, including the PIER-36TRLP-IPI, PIER-36TR-IPI, ST-36TRLP-IPI, and ST-36TR-IPI, are designed to provide both aesthetic appeal and unparalleled heating performance, making them perfect for a variety of living spaces.

One of the defining features of these units is their contemporary design, which integrates seamlessly into modern interiors. The sleek, linear appearance allows for versatile installation options, whether in a wall or as a standalone feature. With a focus on maximizing visual impact, the large glass viewing area provides an unobstructed view of the flames, creating an inviting ambiance.

In terms of technology, these fireplaces are equipped with advanced ignition systems, specifically the IntelliFire® ignition system, which intelligently manages flame levels and optimizes efficiency. This technology not only aids in ease of use but also enhances safety, reducing the risk of unintended ignition.

The LifeStyle series also emphasizes energy efficiency. With an emphasis on reducing environmental impact, these fireplaces boast high efficiency ratings, ensuring that homeowners enjoy warmth without excessive energy consumption. The incorporation of direct vent technology allows for better heat retention indoors while drawing in fresh air from outside, minimizing drafts.

When it comes to performance, the LifeStyle models deliver reliable heating capabilities. Each unit is capable of producing up to 36,000 BTUs, ensuring sufficient warmth for medium to large spaces. This output, combined with adjustable flame height and ember bed options, allows users to customize their heating experience according to personal preferences.

Another characteristic of the LifeStyle series is the extensive range of aesthetically pleasing decorative options. Owners can select from various media, such as glass or ceramic logs, which add a touch of style to the fireplace while complementing the overall decor of the room.

Finally, easy maintenance is a hallmark of the LifeStyle series. Many components are designed for straightforward accessibility, making routine upkeep simple and hassle-free. This attention to practicality ensures that homeowners can enjoy their fireplace without the burden of complicated maintenance routines.

In summary, the Heat & Glo LifeStyle PIER and ST series combines elegant design, advanced technology, and efficient heating, making them a sought-after choice for homeowners looking to enhance their living spaces with a modern fireplace solution.