Heat & Glo LifeStyle PIER-36TR-IPI Operating Instructions User Guide, Gas Fireplace Safety

Page 9

2 Operating Instructions User Guide

A. Gas Fireplace Safety

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

If you expect that small children or vulnerable adults may come into contact with this fireplace, the following precau- tions are recommended:

Install a physical barrier such as:

-A decorative firescreen.

-Adjustable safety gate.

Install a switch lock or a wall/remote control with child protection lockout feature.

Keep remote controls out of reach of children.

Never leave children alone near a hot fireplace, whether operating or cooling down.

Teach children to NEVER touch the fireplace.

Consider not using the fireplace when children will be present.

Contact your dealer for more information, or visit: www. hpba.org/safety-information.

To prevent unintended operation when not using your fire- place for an extended period of time (summer months, vacations, trips, etc):

Remove batteries from remote controls.

Turn off wall controls.

Unplug 3 volt adapter plug and remove batteries on IPI models.

B. Your Fireplace

WARNING! DO NOT operate fireplace before read- ing and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire or injury.

DECORATIVE DOORS

(NOT SHOWN)

SECTION 2.E.

FIXED GLASS ASSEMBLY

SECTION 14.G.

MANTEL

SECTION 5.D

HEARTH

CLEAR SPACE

SECTION 2.D.

Figure 2.1 General Operating Parts

Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI2176-900 Rev. F • 8/11

9

Image 9
Contents What to do if you smell gas ModelsHomeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsLimited Lifetime Warranty  B. Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Fixed Glass Assembly Blower InstallationRemote Controls, Wall Controls and Wall Switches Blower Kit optionalFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Maintenance Tasks-Qualified Service Technician Ember Light ReplacementGasket Seal and Glass Assembly Inspection LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChasePIER-36TR-IPI Pier Combustible Mantel Mantel and Wall Projections See-Through Combustible MantelSee-Through Non-Combustible Mantel Pier Non-Combustible MantelTOP View Vent Termination Minimum Clearances Termination LocationsCovered Alcove Applications = AIR Supply Inlet = Area Where Terminal is not PermittedInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Approved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsVent Diagrams To SLP series vent pipe, if desiredTop Vent Horizontal Termination Top Vent Horizontal Termination One Elbow Two Elbows V1 Minimum H1 MaximumMinimum + H 2 Maximum Top Vent Horizontal Termination Three Elbows Exhaust restrictor Instructions Break Here Maximum + V 2 Minimum Two Elbows Three ElbowsPage H1 Maximum V1 Minimum H2 Maximum H1+ H2 Maximum Rear Vent Horizontal Termination Two ElbowsMinimum + H 2 Maximum Rear Vent Vertical Termination One ElbowH1 Maximum V1 Minimum H1+ H2 Maximum Rear Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe DVP SLP Vertical Penetration FramingInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Cut the metal retaining band Rear VentSecuring An Appliance Securing and Leveling the ApplianceAttach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination DVP-HPC1 DVP-HPC2 Install Horizontal Termination Cap DVP and SLP PipeFuel Conversion Gas InformationGas Pressure Gas ConnectionJunction Box Installation Wiring RequirementsIntelliFire Ignition System Wiring Electrical Service and RepairPrecautions WSK-MLT Multifunction Wall SwitchWiring the Wall Switch Connect the Temperature Sensor Switch for Fan optional Install the Flame SolenoidSetting Flame Height/Manifold Pressure Wall Switch Button OperationWSK-MLT Operating Instructions Up and Down Arrows To install the Splatter Guard FinishingSplatter Guard To Remove the Splatter Guard To Close the Lower Access Panel12 Minimum Vertical and Maximum Horizontal Facing Material 17 Noncombustible Facing DiagramST-36TR-IPI Finishing Material22 Pier Door Finishing Elevated Hearth Systems Appliance Setup Placing the Ember Material Placement of EmbersInch Install the Log Assembly5 4 Notch engaged with grate tine NotchAir Shutter Setting Install Trim Kits and SurroundsTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Sure specifications. Polish flame-sensing rod with fine steel Reference Materials Appliance Dimension DiagramElectrical Access GAS Line Left View Front View Right View DVP-AS2 Vent Components DiagramsDVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M DVP-TV DVP-HRC-SS Optional Wire Harness660 mm ElbowExtended Heat Shield Ceiling FirestopBlack Support Box-Black Wall Thimble-BlackAdapter Log Set Assembly Service PartsAt Depot See-Through Gas FireplacePier Direct Vent Fireplace StockedPIER-36TR, ST-36TR-IPI #17 Valve AssemblyST-36TR-IPI, PIER-36TR-IPI Service Parts ListContact Information

PIER-36TR-IPI, PIER-36TRLP-IPI, ST-36TRLP-IPI, ST-36TR-IPI specifications

Heat & Glo is renowned for its innovative and stylish fireplace solutions, and their LifeStyle series is no exception. The LifeStyle models, including the PIER-36TRLP-IPI, PIER-36TR-IPI, ST-36TRLP-IPI, and ST-36TR-IPI, are designed to provide both aesthetic appeal and unparalleled heating performance, making them perfect for a variety of living spaces.

One of the defining features of these units is their contemporary design, which integrates seamlessly into modern interiors. The sleek, linear appearance allows for versatile installation options, whether in a wall or as a standalone feature. With a focus on maximizing visual impact, the large glass viewing area provides an unobstructed view of the flames, creating an inviting ambiance.

In terms of technology, these fireplaces are equipped with advanced ignition systems, specifically the IntelliFire® ignition system, which intelligently manages flame levels and optimizes efficiency. This technology not only aids in ease of use but also enhances safety, reducing the risk of unintended ignition.

The LifeStyle series also emphasizes energy efficiency. With an emphasis on reducing environmental impact, these fireplaces boast high efficiency ratings, ensuring that homeowners enjoy warmth without excessive energy consumption. The incorporation of direct vent technology allows for better heat retention indoors while drawing in fresh air from outside, minimizing drafts.

When it comes to performance, the LifeStyle models deliver reliable heating capabilities. Each unit is capable of producing up to 36,000 BTUs, ensuring sufficient warmth for medium to large spaces. This output, combined with adjustable flame height and ember bed options, allows users to customize their heating experience according to personal preferences.

Another characteristic of the LifeStyle series is the extensive range of aesthetically pleasing decorative options. Owners can select from various media, such as glass or ceramic logs, which add a touch of style to the fireplace while complementing the overall decor of the room.

Finally, easy maintenance is a hallmark of the LifeStyle series. Many components are designed for straightforward accessibility, making routine upkeep simple and hassle-free. This attention to practicality ensures that homeowners can enjoy their fireplace without the burden of complicated maintenance routines.

In summary, the Heat & Glo LifeStyle PIER and ST series combines elegant design, advanced technology, and efficient heating, making them a sought-after choice for homeowners looking to enhance their living spaces with a modern fireplace solution.