E. Vent Diagrams

To replace the first starter elbow with two 45° elbows, refer to Figure 7.3. All other 90° elbows can be replaced with two 45° elbows.

General Rules:

A maximum of three 90° elbows (or six 45° elbows) may be used in any vent configuration. Some elbows may be installed horizontally. See Figure 7.6.

Elbows may be placed back to back anywhere in the system as long as the first 90° elbow is a starter elbow except as shown in Figure 7.3.

When penetrating a combustible wall, a wall shield firestop must be installed.

When penetrating a combustible ceiling, a ceiling firestop must be installed.

Horizontal runs of vent do not require vertical rise; horizontal runs may be level.

Note: The Multi-Sided series fireplaces can adapt

to SLP series vent pipe, if desired.

When venting off the top of the unit, attach a DVP-2SLadapter to the appliance starting collar, immediately followed by a minimum 48 inch vertical section of SLP series vent pipe.

After the 48 inch vertical section, the venting table rules must be followed. The first 48 inch vertical section is NOT counted as part of the vertical components in the table. It is still counted as part of the overall maximum run. All venting table rules for the vent run must still be followed.

Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal

1. Top Vent - Horizontal Termination - (continued)

Top Vent—Horizontal Termination—Two 45° Elbows

Installation requirements to replace the first 90° elbow with two 45° elbows:

4 ft min.

(1.22 m)

Note: Reference Figure 7.14 for special instructions for use of 45º elbow on rear vent appliances.

16 ft max.

(4.87 m)

Figure 7.3 Minimum Installation Requirements for Two 45° Elbows-Top Vent-Horizontal Termination

Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI2176-900 Rev. F • 8/11

27

Image 27
Contents What to do if you smell gas ModelsHomeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty  B. Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Blower Kit optional Blower InstallationFixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Logs Ember Light ReplacementMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChasePIER-36TR-IPI Pier Non-Combustible Mantel Mantel and Wall Projections See-Through Combustible MantelPier Combustible Mantel See-Through Non-Combustible MantelTOP View Vent Termination Minimum Clearances Termination LocationsCovered Alcove Applications = AIR Supply Inlet = Area Where Terminal is not PermittedInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyVent Diagrams To SLP series vent pipe, if desiredTop Vent Horizontal Termination Top Vent Horizontal Termination One Elbow Two Elbows V1 Minimum H1 MaximumMinimum + H 2 Maximum Top Vent Horizontal Termination Three Elbows Exhaust restrictor Instructions Break Here Maximum + V 2 Minimum Two Elbows Three ElbowsPage H1 Maximum V1 Minimum H2 Maximum H1+ H2 Maximum Rear Vent Horizontal Termination Two ElbowsMinimum + H 2 Maximum Rear Vent Vertical Termination One ElbowH1 Maximum V1 Minimum H1+ H2 Maximum Rear Vent Vertical Termination Three ElbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP SLP Vertical Penetration FramingInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Cut the metal retaining band Rear VentSecuring An Appliance Securing and Leveling the ApplianceAssemble Pipe Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination DVP-HPC1 DVP-HPC2 Install Horizontal Termination Cap DVP and SLP PipeGas Connection Gas InformationFuel Conversion Gas PressureElectrical Service and Repair Wiring RequirementsJunction Box Installation IntelliFire Ignition System WiringPrecautions WSK-MLT Multifunction Wall SwitchWiring the Wall Switch Connect the Temperature Sensor Switch for Fan optional Install the Flame SolenoidSetting Flame Height/Manifold Pressure Wall Switch Button OperationWSK-MLT Operating Instructions Up and Down Arrows To install the Splatter Guard FinishingSplatter Guard To Remove the Splatter Guard To Close the Lower Access Panel12 Minimum Vertical and Maximum Horizontal Facing Material 17 Noncombustible Facing DiagramST-36TR-IPI Finishing Material22 Pier Door Finishing Elevated Hearth Systems Appliance Setup Placing the Ember Material Placement of EmbersInch Install the Log Assembly5 4 Notch engaged with grate tine NotchAir Shutter Setting Install Trim Kits and SurroundsTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Sure specifications. Polish flame-sensing rod with fine steel Reference Materials Appliance Dimension DiagramElectrical Access GAS Line Left View Front View Right View DVP-AS2 Vent Components DiagramsDVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M DVP-TV DVP-HRC-SS Optional Wire HarnessCeiling Firestop Elbow660 mm Extended Heat ShieldBlack Support Box-Black Wall Thimble-BlackAdapter See-Through Gas Fireplace Service PartsLog Set Assembly At DepotPier Direct Vent Fireplace StockedPIER-36TR, ST-36TR-IPI #17 Valve AssemblyST-36TR-IPI, PIER-36TR-IPI Service Parts ListContact Information

PIER-36TR-IPI, PIER-36TRLP-IPI, ST-36TRLP-IPI, ST-36TR-IPI specifications

Heat & Glo is renowned for its innovative and stylish fireplace solutions, and their LifeStyle series is no exception. The LifeStyle models, including the PIER-36TRLP-IPI, PIER-36TR-IPI, ST-36TRLP-IPI, and ST-36TR-IPI, are designed to provide both aesthetic appeal and unparalleled heating performance, making them perfect for a variety of living spaces.

One of the defining features of these units is their contemporary design, which integrates seamlessly into modern interiors. The sleek, linear appearance allows for versatile installation options, whether in a wall or as a standalone feature. With a focus on maximizing visual impact, the large glass viewing area provides an unobstructed view of the flames, creating an inviting ambiance.

In terms of technology, these fireplaces are equipped with advanced ignition systems, specifically the IntelliFire® ignition system, which intelligently manages flame levels and optimizes efficiency. This technology not only aids in ease of use but also enhances safety, reducing the risk of unintended ignition.

The LifeStyle series also emphasizes energy efficiency. With an emphasis on reducing environmental impact, these fireplaces boast high efficiency ratings, ensuring that homeowners enjoy warmth without excessive energy consumption. The incorporation of direct vent technology allows for better heat retention indoors while drawing in fresh air from outside, minimizing drafts.

When it comes to performance, the LifeStyle models deliver reliable heating capabilities. Each unit is capable of producing up to 36,000 BTUs, ensuring sufficient warmth for medium to large spaces. This output, combined with adjustable flame height and ember bed options, allows users to customize their heating experience according to personal preferences.

Another characteristic of the LifeStyle series is the extensive range of aesthetically pleasing decorative options. Owners can select from various media, such as glass or ceramic logs, which add a touch of style to the fireplace while complementing the overall decor of the room.

Finally, easy maintenance is a hallmark of the LifeStyle series. Many components are designed for straightforward accessibility, making routine upkeep simple and hassle-free. This attention to practicality ensures that homeowners can enjoy their fireplace without the burden of complicated maintenance routines.

In summary, the Heat & Glo LifeStyle PIER and ST series combines elegant design, advanced technology, and efficient heating, making them a sought-after choice for homeowners looking to enhance their living spaces with a modern fireplace solution.