Beckett CF2300, CF1400 manual Prepare the burner for start-up, Do Not Bypass Safety Controls

Page 16

Prepare the burner for start-up

Do Not Bypass Safety

Controls

Tampering with, or bypassing safety controls could lead to equipment malfunction and result in asphyxiation, explosion or fire.

ySafety controls are designed and installed to provide protection.

yDo not tamper with, or bypass any safety control.

yIf a safety control is not functioning properly, shut off all main electrical power and fuel supply to the burner and call a qualified service agency immediately.

Keep Service Access

Covers Securely Installed

These covers must be securely in place to prevent electrical shock, damage from external elements, and protect against injury from moving parts.

yAll covers or service access plates must be in place at all times except during maintenance and service.

yThis applies to all controls, panels, enclosures, switches, and guards or any component with a cover as part of its design.

Professional Installation

and Service Required

Incorrect installation and mishandling of start- up could lead to equipment malfunction and result in asphyxiation, explosion or fire.

yThis burner must be installed and prepared for start- up by a qualified service technician who is trained and experienced in commercial oil burner system installation and operation.

yDo not attempt to start the burner unless you are fully qualified.

yDo not continue with this procedure until all items in the “Prepare the burner for start-up” section have been verified.

yCarefully follow the wiring diagrams, control

instruction sheets, flame safeguard sequence of operation, test procedures and all appliance manufacturer’s directions that pertain to this installation.

yIf any of these items are not clear or are unavailable, call Beckett at 1-800-645-2876 for assistance.

Start-up checklist – Verify the following before at- tempting to start burner.

…Combustion air supply and venting have been inspected and verified to be free of obstructions and installed in accordance with all applicable codes.

…Oil nozzle has been selected correctly and securely installed in the nozzle adapter.

…Fuel unit by-pass plug has not been installed for one- pipe oil system.

…By-pass plug has been installed for two-pipe oil system.

…Fuel connection to nozzle line assembly is secure.

…Dimension Z has been set per this instruction manual.

…Fuel supply line is correctly installed, the oil tank is sufficiently filled, and shut-off valves are open.

…Burner is securely mounted in appliance, with pressure firing plate and gasket installed for pressurized chamber application.

…Appliance has been filled with water (boilers) and controls have been operationally checked.

…Burner has been installed in accordance with appliance manufacturer’s instructions (when available).

…Also refer to appliance manufacturer’s instructions (when available) for start-up procedures.

‰Z dimension

Should be set per these instructions (see page 10). The top acorn nut (Figure 12, item d) should never be loosened once the Z dimension is initially set.

‰Adjusting plate assembly (Figure 12)

Make sure spline nut (item b) and bottom acorn nut (item c) are loose before proceeding to next section.

‰Initial head position (Figure 12)

The indicator plate assembly (item e) markings correspond to head position settings.

ySlide the secondary adjusting plate (item f) toward the rear of the burner until the number on the indicator plate corresponds to the initial head setting given in Tables 4a and 4b for the desired firing rate and burner (high-fire).

yFigure 12 shows a typical example, with a head setting of 6.

yWhen the head position has been set, tighten the bottom acorn nut (item c) and the spline nut (item b).

16

Form 6104 BCF23-R05

 

Image 16
Contents Potential for Fire, Smoke and Asphyxiation Hazards To the Professional, Qualified Installer or Service AgencyTo the Homeowner or Equipment Owner Table of Contents Specifications General InformationAgency approvals Pre-installation checklist Professional Installer/Service Agency ResponsibilityOwner’s Responsibility Follow These Instructions ExactlyOil Supply Pressure Control Required Correct Nozzle and Flow Rate Required‰ Fuel supply ‰ Nozzle pressureNozzle capacities ‰ Vent system‰ Verify burner components ‰ Verify firing rateAir tube capacity Versus firebox pressure ‰ Verify air tubeMount the burner Protect Against Stray Light LockoutProtect Against Dust Moisture Protect the Air Tube From Overheating‰ Install nozzle ‰ Check electrode settingsMaintain Electrode Specifications ‰ Mount air tube to burner‰ Install nozzle line assembly ‰ Set dimension ZBurner installed in appliance front ‰ Insert burnerFactory-Installed Pump Bypass Plug Install Oil Supply To SpecificationsConnect fuel lines One-pipe oil flow with B pump Fuel unit gearset capacitiesWire the burner R7184B Electrical Shock HazardSequence of operation Typical Sequence of operation typicalDo Not Bypass Safety Controls Keep Service Access Covers Securely InstalledProfessional Installation Service Required Prepare the burner for start-upCF1400 Initial indicator adjustment plate settings CF2300 Initial indicator adjustment plate settings‰ Initial air settings Damper Motor with CoverProfessional Service Required Start the burnerHot Gas Puff-back Heavy Smoke Hazard Explosion and Fire Hazard‰ Set high-fire air ‰ Start burner and vent air from oil line‰ Set low-fire air Perform Regular Maintenance Annual ServiceMonthly maintenance by owner Annual Professional Service RequiredPart Name Replacement PartsDescription Burner Replacement Parts Flange a Flange B Flange CWarranty Limited Warranty Information
Related manuals
Manual 24 pages 24.93 Kb

CF2300, CF1400 specifications

Beckett has long been a household name in the heating and oil burner industry, renowned for producing equipment that excels in efficiency, reliability, and innovation. Among its impressive range of products, the CF1400 and CF2300 models stand out as exceptional offerings in the category of oil burners.

The Beckett CF1400 is designed for residential applications, delivering a robust performance that satisfies heating needs while minimizing energy consumption. This model is equipped with advanced technology that ensures precise fuel atomization, which translates into cleaner combustion and lower emissions. With adjustable combustion settings, users can optimize the burner for different home heating systems, ensuring peak performance regardless of the conditions.

In contrast, the CF2300 model is engineered for larger residential or light commercial setups. This powerhouse of a burner leverages enhanced fuel delivery systems and cutting-edge control features that allow for efficient operation and maintenance. Its design incorporates a heat exchanger that maximizes heat transfer, resulting in improved energy efficiency. Beckett’s commitment to quality is evident in its use of durable materials, ensuring that these units offer longevity and consistent performance over time.

Both models share several key technologies and characteristics. They are compatible with various heating oil types and can accommodate different fuel tank arrangements. The burners feature adjustable air settings, allowing for easy tuning to achieve optimal combustion performance. The CF1400 and CF2300 are also characterized by quiet operation, ensuring homeowners can enjoy a warm environment without disruptive noise levels.

Safety is paramount in the design of the CF series. Each unit comes equipped with safety controls that prevent overheating and other potential hazards, providing peace of mind to users. Furthermore, installation is user-friendly, and regular maintenance is simplified, reducing service costs and extending the lifespan of the burners.

The Beckett CF1400 and CF2300 models exemplify the brand's dedication to technological advancement and user-centric design. With their combination of efficiency, reliability, and cutting-edge features, these oil burners continue to be preferred choices for homeowners looking to improve their heating systems. Whether for residential or light commercial use, these models provide dependable heating solutions that align with modern energy standards.