Replacement Parts

For best performance specify genuine Beckett replacement parts

Item

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

Part Name

Timer

Oil Valve

Knurled Nut

Adjusting plate assembly

Fuel pump

Damper motor

Pedestal kit

Fuel lines

Sight glass

Rear cover door assembly

Control

Coupling hole plug Coupling access door

Head assembly

Electrode assembly

Ignition leads

Nozzle line assembly Air tube Transformer

Coupling

Blower wheel

Motor

Motor relay (not shown)

Adjustable flange

Description

 

Part No.

Nozzle valve delay

 

21295U

Box mounted

 

21789U

All models

 

3666

w/ cast aluminum door

 

5994U

w/ stamped sheet-metal door

 

5201701U

B2TA-8245

 

21313U

H3PAN-C150H

 

21309U

2-stage

 

750601U

All models

 

51193

Specify length

 

-

All models

 

31346

w/ cast aluminum door*

CF1400

5994U

 

CF2300

51204U

w/ stamped sheet-metal door*

CF1400

5201301U

 

CF2300

5201302U

Specify

 

-

use with threaded hole

 

32439U

use with rectangular opening

 

16703GY

CF1400

 

5978

CF2300

 

51203

All models

 

51212

8-1/4” long

 

5990082

11-3/4” long

 

5990116

15-1/4” long

 

5990152

19-1/4” long

 

5990192

Refer to Figure 5, Page 9

 

 

 

 

Refer to Figure 4, Page 8

 

 

12,000 volt

 

 

 

51214

B pump

 

21290

H pump

 

21308

CF1400 - 5.59” x 3.09”

 

21268U

CF2300 - 6.75” x 3.13”

 

21267U

120/208-230 single phase

CF1400

21401U

 

CF2300

21402U

208-230/460 three phase

CF1400

21638U

 

CF2300

21499U

120V single phase

 

7273

208V single phase

 

7300

three phase

 

2194301

 

 

 

see Figure 15 on opposite page

22

Form 6104 BCF23-R05

 

Image 22
Contents Potential for Fire, Smoke and Asphyxiation Hazards To the Professional, Qualified Installer or Service AgencyTo the Homeowner or Equipment Owner Table of Contents Specifications General InformationAgency approvals Owner’s Responsibility Pre-installation checklistProfessional Installer/Service Agency Responsibility Follow These Instructions Exactly‰ Fuel supply Oil Supply Pressure Control RequiredCorrect Nozzle and Flow Rate Required ‰ Nozzle pressure‰ Verify burner components Nozzle capacities‰ Vent system ‰ Verify firing rateAir tube capacity Versus firebox pressure ‰ Verify air tubeProtect Against Dust Moisture Mount the burnerProtect Against Stray Light Lockout Protect the Air Tube From OverheatingMaintain Electrode Specifications ‰ Install nozzle‰ Check electrode settings ‰ Mount air tube to burner‰ Install nozzle line assembly ‰ Set dimension ZBurner installed in appliance front ‰ Insert burnerFactory-Installed Pump Bypass Plug Install Oil Supply To SpecificationsConnect fuel lines One-pipe oil flow with B pump Fuel unit gearset capacitiesWire the burner R7184B Electrical Shock HazardSequence of operation Typical Sequence of operation typicalProfessional Installation Service Required Do Not Bypass Safety ControlsKeep Service Access Covers Securely Installed Prepare the burner for start-upCF1400 Initial indicator adjustment plate settings CF2300 Initial indicator adjustment plate settings‰ Initial air settings Damper Motor with Cover Hot Gas Puff-back Heavy Smoke Hazard Professional Service Required Start the burner Explosion and Fire Hazard‰ Set high-fire air ‰ Start burner and vent air from oil line‰ Set low-fire air Monthly maintenance by owner Perform Regular MaintenanceAnnual Service Annual Professional Service RequiredPart Name Replacement PartsDescription Burner Replacement Parts Flange a Flange B Flange CWarranty Limited Warranty Information