Munchkin MUNCHKIN HIGH EFFICIENCY HEATER with the "925" Controller manual Part 4. Venting

Page 14

VENTING

PART 4. VENTING

DANGER

It is extremely important to follow these venting instructions carefully. Failure to do so can cause severe personal injury, death or substantial property damage.

A. APPROVED VENTING MATERIALS

Exhaust Vent and Extensions in Plastic 2", 3" and 4" Pipe Schedule 40 or 80.

1.Non Foam Core PVC Pipe

2.Non Foam Core CPVC Pipe

3.Non Foam Core ABS Pipe

Vent Piping must conform to following

1.PVC Non Foam Core Pipe (Polyvinyl Chloride) to ASTM D-1785 or D-1784 Class 12454-B, Formerly designated Type 1, Grade 1.

2.CPVC (Chlorinated Polyvinyl Chloride) Class 23447-B, Formerly designated Type IV, Grade 1 con- forming to ASTM D-1784.

3.ABS (Acrylonitrile-Butadiene-Styrene) Class 3-2-2-2-2 conforming to ASTM D3965.

DANGER

Foam Core Pipe is not to be used in connecting the exhaust pipe.

The Munchkin is a direct vent appliance. The Munchkin is listed as a Category IV Condensing Appliance. (The Munchkin Venting is rated at Zero Clearance to combustibles.)

Note: For Concrete construction or to meet certain fire codes, exhaust and inlet piping at the wall penetration to the Munchkin must be CPVC Schedule 40 or 80 to meet local fire codes. The balance from the penetrated wall to the outside, may be PVC Schedule 40 or 80.

Inlet Air Vent

Use the same material as used for exhaust in either 2", 3" or 4" Plastic Pipe. Cellular Foam Core Pipe may be used for the inlet only, NEVER ON EXHAUST PIPING!

WARNING

This vent system will operate with a positive pressure in the vent pipe. Do not connect vent connectors serving appliances by natural draft into any portion of mechanical draft systems operating under positive pressure.

14

Image 14
Contents Munchkin High Efficiency Heater With the 925 ControllerUsing this Manual Special Attention BoxesTable of Contents HOW IT Operates Munchkin Ratings and DimensionsPart 1. General Information Recommended Service Clearances Dimensions 80M 140M/199M PRE-INSTALLATION Requirement GeneralElectrical Connection Part 2. ElectricalPressure Relief Valve Electrical Connection Wiring Directly to Central Heating Circulator GAS Piping Part 3. GAS ConnectionGAS Connection GAS TableDungs GAS Valve Part 4. Venting Approved Venting MaterialsVenting the Munchkin Direct vent terminal clearance Minimum clearance, C Longer Vent Runs Vented ApplianceHeater Removal from a Common Vent System Condensate RemovalDiagrams for Sidewall Venting Venting Diagrams for Vertical Venting Part 5. Piping Hydronic Piping with Circulators or Zone ValvesCirculator Sizing Munchkin T50M Munchkin T80M/80M Munchkin 140M Munchkin 199MFill and Purge Heating System Piping Symbol Legend Piping IllustrationsOFF Zone valves Piping Zone valves Make-up water Piping Space heating zone circuit Zone Circulators Make-up water PB1 PB2 PB1 PB2 Items to be Checked Before Lighting the Munchkin Part 6. START-UP ProceduresSequence of Operation Lighting Instructions Operating InstructionsAdjusting the Temperature on the Munchkin Display Status MenuTest Mode To Turn OFF GAS to AppliancePart 7. Troubleshooting Munchkin Error Code925 Control Board Error Codes Resistance Tables Condensate Cleaning Instructions Part 8. MaintenanceMaintenance Procedures Before Each Heating SeasonMaintenance Control Wiring Layout Munchkin ControllerMaintenance Maintenance Page Page Munchkin R1

MUNCHKIN HIGH EFFICIENCY HEATER with the "925" Controller specifications

The Munchkin High Efficiency Heater, equipped with the advanced "925" Controller, represents a significant advancement in heating technology for both residential and commercial applications. Known for its reliability and exceptional performance, this heater is designed to provide efficient heating while minimizing energy costs and environmental impact.

The Munchkin High Efficiency Heater operates on a condensing technology that extracts heat from exhaust gases. This process allows for higher efficiency rates, often exceeding 95%. By recovering heat that would otherwise be lost, the heater maximizes energy utilization, making it an eco-friendly choice for homeowners and businesses alike.

One of the standout features of the Munchkin 925 Controller is its user-friendly interface, which allows for effortless operation and monitoring of the heating system. The controller comes with advanced diagnostic capabilities that provide real-time feedback on system performance. Users can easily adjust settings, program schedules, and monitor energy consumption, ensuring optimal comfort and efficiency.

Furthermore, the Munchkin High Efficiency Heater is equipped with a variety of features that enhance its performance and user experience. The unit is designed with a durable heat exchanger made from stainless steel, which not only improves heat transfer but also ensures longevity and resistance to corrosion.

The heater operates quietly, making it suitable for installation in residential settings, including bedrooms and living spaces. Additionally, its compact design allows for flexible installation options, even in constrained spaces. The Munchkin unit is also compatible with multiple venting options, providing further versatility in installation configuration.

Safety features are a priority in the design of the Munchkin Heater. It includes built-in freeze protection, ensuring that the system operates effectively even in low temperatures. The unit also has an array of safety sensors that monitor for conditions such as flue blockage and overheating, triggering automatic shut-off mechanisms to prevent potential hazards.

In conclusion, the Munchkin High Efficiency Heater with the "925" Controller is a cutting-edge solution for efficient heating. With its superior performance, advanced controller system, durable construction, and comprehensive safety features, it remains a top choice for those looking to improve their heating efficiency while reducing energy consumption. Whether it's for residential or commercial use, the Munchkin heater promises reliability and comfort in any environment.