Burnham MST288, MST396, MST629, MST513 manual Table of Contents

Page 4

WARNING

This boiler contains very hot water under high pressure. Do not unscrew any pipe fittings nor attempt to disconnect any components of this boiler without positively assuring the water is cool and has no pressure. Always wear protective clothing and equipment when installing, starting up or servicing this boiler to prevent scald injuries. Do not rely on the pressure and temperature gauges to determine the temperature and pressure of the boiler. This boiler contains components which become very hot when the boiler is operating. Do not touch any components unless they are cool.

This boiler must be properly vented. The chimney must be inspected for any obstructions and cleaned prior to each heating season. A clean and unobstructed chimney flue is necessary to produce the minimum draft required to safely evacuate noxious fumes that could cause personal injury or loss of life. Evidence of loose debris and or condensate induced stains at the base of the chimney flue, connector or smokepipe joints may be signs of condensing flue gases. Flue gas condensate is corrosive, which requires special consideration and must be addressed immediately. Refer to Section V, "Venting and Air Intake Piping".

This boiler needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

This boiler is supplied with controls which may cause the boiler to shut down and not re-start without service. If damage due to frozen pipes is a possibility, the heating system should not be left unattended in cold weather; or appropriate safeguards and alarms should be installed on the heating system to prevent damage if the boiler is inoperative.

This boiler is designed to burn No. 2 fuel oil only. Do not use gasoline, crankcase drainings, or any oil containing gasoline. Never burn garbage or paper in this boiler. Do not convert to any solid fuel (i.e. wood, coal). Do not convert to any gaseous fuel (i.e. natural gas, LP). All flammable debris, rags, paper, wood scraps, etc., should be kept clear of the boiler at all times. Keep the boiler area clean and free of fire hazards.

All boilers equipped with burner swing door have a potential hazard which, if ignored, can cause severe property damage, personal injury or loss of life. Before opening swing door, unplug burner power cord from receptacle located in lower right corner of jacket front panel and turn off service switch to boiler to prevent accidental firing of burner outside the combustion chamber. Be sure to tighten swing door fasteners completely when service is completed.

TABLE OF CONTENTS

I.

Pre-Installation

7

VII.

. . . . . . . .Oil Piping

. . . . . . . . . .

37

 

 

 

 

 

 

 

II.

Unit-Pak Boiler Assy

9

VIII.

System Start-Up

. . . . . . . . . .

39

 

 

 

 

 

 

III.

Steam Boiler Trim & Piping

22

IX.

Maintenance & Service Instructions . . .

45

 

 

 

 

 

 

 

IV.

Tankless & Indirect Water Heater Piping .

24

X.

Boiler Cleaning

. . . . . . . . . .

48

 

 

 

 

 

 

 

V.

Venting & Air Intake Piping

27

XI.

Trouble Shooting

. . . . . . . . . .

50

 

 

 

 

 

 

 

VI.

Electrical

32

XII.

Repair Parts

51

 

 

 

 

 

 

 

Image 4
Contents MegaSteam 100618-01R4-5/08 Price $3.00Important Information Read Carefully Page Table of Contents Page =B=R NET Section I PRE-INSTALLATION Boiler is Suitable for InstallationPage Control Carton Insulation WrapperJacket Carton Instruction/Label BagProcedure To Open, Close and Secure Burner Swing Door Jacket Front Panel InstallationBoiler Removal from Skid Page Page Baffle Usage Flueway Baffle InstallationClosing / Securing Burner Swing Door Jacket Rear Panel Installation Flue Cleanout Covers and Smokebox Collar InstallationUNC Less HeaterSide and Top Jacket Panel Installation External Electrical Enclosure MountingTrim and Controls Installation. Pressure Limit Installation Pressure Gauge and Gauge Glass InstallationFloat-Type Lwco and Pressure Limit Installation Safety Valve and Drain Valve Installation Oil Burner InstallationDo not install burner without gasket Aquastat bulb must be fully inserted into the wellOil Burner Installation Section III Steam Boiler Piping & Trim Evaluate the existing steam systemRecommended Boiler Piping for Gravity Return Steam Boiler Section IV Tankless & Indirect Water Heater Piping Schematic Tankless Water Heater Piping Tankless Heater Data Alliance Water Heater Piping with MegaSteam Boiler Section V Venting & Air intake piping Chimney ConnectorChimney Venting Recommended Vent Pipe Arrangement and Chimney Requirements Stack Temperature DraftMinimum Clearances Do not exceed maximum allowable air intake lengthSeal all external joints with weatherproof caulk Section VI Electrical GeneralWiring Diagram, Steam, Hydrolevel CG450 Probe Lwco Wiring Diagram, Steam, McDonnell & Miller PS-801 Probe Lwco Wiring Diagram, Steam, McDonnell & Miller #67 Float Lwco Boiler Sequence of Operation with Probe Lwco See Figure Boiler Sequence of Operation with Float Lwco See FigureSingle Pipe Oil Lines Single Pipe Oil LineTwo-Stage Units 3450 RPM Two Pipe Systems Two Pipe Oil LinesSingle-Stage Units 3450 RPM Two Pipe Systems Always Inspect Installation Before Starting Burner Section Viii System START-UPAdjusting Fuel Pump Pressure Adjust OIL Burner While OPERATING. flame presentPage R7184 Terminals, LED and Reset Button Cad Cell Resistance When Sensing FlameCad Cell Location Jumper must be removed after this checkAvoid Breathing Fiber Particulates and Dust Section Ix Maintenance and Service Instructions Steam BoilersPage Gallons / Month MST288 MST396 MST513 MST629 Clean the Flueways See Figure Section X Boiler CleaningClean the Combustion Chamber Page Section XI Trouble Shooting Section XII Repair Parts Bare Boiler Assembly Bare Boiler Assembly Bare Boiler Assembly 1FF Jacket Assembly Jacket Assembly MST288 Thru MST629 Steam Boilers Trim and Controls MST Trim and Controls Beckett AFG Burner Beckett OIL Burner Part NOS. for MegaSteam Series Boilers Beckett AFG Burner specifications OUTService Record Limited Warranty

MST513, MST396, MST629, MST288 specifications

The Burnham MST series, comprising models MST396, MST629, MST513, and MST288, is renowned for its robust design and exceptional performance in the boiler industry. Each model is engineered to provide optimal efficiency and reliability for residential and commercial heating applications.

The Burnham MST396 is distinguished by its high thermal efficiency and advanced combustion technology. This model features a cast iron heat exchanger which ensures superior heat retention and distribution. The MST396 is equipped with a powerful burner that allows for variable firing rates, maximizing efficiency and extending the lifespan of the unit. Additionally, it includes a built-in electronic ignition system that enhances reliability while reducing the need for frequent maintenance.

Moving to the MST629, this model is designed for larger applications needing higher output. It boasts a significant BTU input and utilizes a multi-stage burner system. This ensures optimal combustion and adapts to varying demand, providing consistent heat without wasting energy. The MST629 also incorporates enhanced insulation and an advanced flue gas venting system to improve safety and minimize energy loss.

The MST513 caters to mid-sized applications with its adaptable performance and user-friendly features. This model is notable for its compact design, making it suitable for installations with limited space. It uses a two-stage burner for efficient energy use and offers a smart control system that monitors performance in real-time. This allows users to make informed decisions about their energy consumption and maintenance needs, ultimately leading to cost savings.

Lastly, the MST288 is the smaller model in the series, ideal for homes and small businesses. Despite its size, it does not compromise on efficiency. The MST288 features a straightforward design, ensuring ease of installation and maintenance. It utilizes a single-stage burner that provides consistent heat output, making it a reliable choice for low-demand applications. The unit is also equipped with adjustable settings, allowing users to tailor their heating needs effectively.

In summary, the Burnham MST series demonstrates a remarkable blend of innovation and practicality across its models. With features like advanced burner technology, efficient heat exchangers, and smart controls, the MST396, MST629, MST513, and MST288 cater to a wide range of heating needs while prioritizing energy efficiency and user comfort. These models stand out in the market, continually setting a standard for performance and reliability in heating solutions.