Ariston 47-116-12, A/23 MFFI, A/27 MFFI, 47-116-10 Removing the Front Panel, Control Panel

Page 18

3.2Removing the Front Panel

system (sect. 3.4) and run it until the temperature has reached the boiler operating temperature. The system must then be immediately flushed through. The flushing procedure must be in line with BS 7593:1992 Code of practice for treatment of water in domestic hot water central heating systems.

During this operation, we highly recommend the use of a central heating flushing detergent (Fernox Superfloc or equivalent), whose function is to dissolve any foreign matter that may be in the system.

Substances different from these could create serious problems to the pump or other components.

The use of an inhibitor in system such as Fernox MB-1 or equivalent is strongly recommended to prevent corrosion (sludge) damaging the boiler and system.

Failure to carry out this procedure may invalidate the appliance warranty.

To remove the front panel of the casing, proceed as follows:

1.Remove the screw “F” located on the top edge of the panel.

2.Lift and unhook the panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

F

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3 Control Panel

A/23 MFFI - A/27 MFFI

40 50 60 70 80

C C

A - Ignition Lockout Reset Button/Safety (Overheat)Thermostat Reset

B - Ignition Lockout L.E.D.

C - Selector Knob for Summer/Winter/Flue Analysis Modes*

D - Low System Water Level L.E.D.

E- Temperature Adjustment Knob for Domestic Hot Water

F- Heating System Thermometer

G- Safety (Overheat)Thermostat Intervention L.E.D.

H- Adjustment Knob for Heating Temperature

I- On/Off L.E.D.

L - On/Off Switch

O - System Pressure Gauge

* Warning the flue analysis mode must only be selected by a qualified service engineer.

18

B023

Image 18
Contents Mffi A/27 Mffi Table of Contents General Information General InstructionsTechnical Information MffiMffi A/27 Mffi Overall ViewInstallation Reference Standards Siting the ApplianceOverall Dimensions ClearancesMounting the Appliance Electrical ConnectionGas Connection Pipe Work Safety Valve DischargeWater Connections By-passFlue Connections Mains Water Feed Central HeatingFilling Terminal Position B023 Coaxial System Room Thermostat Connection Electrical Diagram ColoursB023 Initial Preparation Water Circuit DiagramMffi Commissioning Filling the Heating SystemRemoving the Front Panel Control PanelSelector Knob for Summer/Winter/Flue Analysis Modes Initial Start-up Operational Adjustments Checks to be run before initial start-up are as followsIgnition Failure Circulation FailureOverheating Draining the System GAS AdjustmentsSafety Shut-off Limescale Build-upMaintenance Changing the Type of GasWiring Diagram for Two Heating Zones MiscellaneousWiring Diagram for Connection to Ariston Unvented Cylinder BlueB023 B023 B023 Cod 99 84 1260 112 B023 Manufacturer Merloni TermoSanitari SpA Italy