Ariston 41-116-07 installation instructions Removing the main heat exchanger

Page 30

3.Remove screw “H” (FIG. 1.14);

4.Gently slide the electrode downward (FIG. 1.15).

FIG. 1.14

H

1.3.4 Removing the main heat exchanger

1.Drain the boiler of water;

2.Release the overheat thermostat sensor “I” (FIG. 1.16);

3.Release the two connection nuts “J” connecting the exchanger to the flow and return pipes (FIG. 1.17);

4.Remove the heat exchanger by sliding forward (FIG. 1.18).

I

FIG. 1.15

To replace, repeat the steps in reverse order, paying particular attention to the following:

a - Centre the electrode in the positioning hole carefully, otherwise the electrode may break;

b -Ensure that the left hand and right hand electrodes are located the correct way round (facing each other), to give the correct spark gap;

c - Check that the cables have been connected correctly;

d-Check that the rubber gasket covers the cable/ electrode connection point completely.

Fig. 1.16

J

FIG. 1.17

FIG. 1.18

6

Image 30
Contents Installation Instructions Type C Boilers Table of Contents General Information Flue connector Installation Overall Dimensions Supply must be fused at 3 a Residual Head of the Boiler Kent TN9 1RA Morley RoadTonbridge 60/100 mm80 mm Extension Piping not insulated Piping insulated Exhaust Restrictor Maximum Risk of Condensation FormingType SystemsRoom Thermostat Connection A11 Overheat Thermostat GAS and Water Circuits H.W. Storage Cylinder Model Commissioning Domestic HOT Water Priority KITControl Panel Combustion Analysis Turn off the boiler GAS Adjustments Methane Gas G20Liquid Butane Gas Liquid Propane Gas G30 G31 Maintenance Page Technical Service Hot Line 01494 Technical InformationManufacturer Merloni TermoSanitari SpA Italy Servicing Instructions Type C Boilers Fault Finding Servicing Instructions Removing the front panelRemoving the sealed chamber front cover Removing the side panelsRemoving the combustion cover Removing the burner and jetsRemoving the electrodes Removing the main heat exchanger Removing the air pressure switch Removing the fanGas escaping with an approved soap and water solution Setting the gas pressuresSetting the minimum and the maximum power of the boiler Setting pressure for soft ignitionRegulating the heating power for Natural gas G20 Regulating the heating power for Butane gas G30Regulating the heating power for Propane gas G31 Removing the spark generator Removing the gas valveRemoving the pump pressure switch Removing the safety valveRemoving the automatic air vent 1. Unscrew valve top Z FIG Removing the pump Removing the pressure gauge Removing the expansion vesselRemoving the overheat thermostat Removing the frost thermostatRemoving the regulation thermostat Checking the fuse Removing the P.C.B.sO1O1 P1 P1 Fault Finding Finding diagrams described in this chapterYES Mbar Diagrams ElectricalSF008A MicroSYSTEM 21/28 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1550

41-116-07 specifications

The Ariston 41-116-07 is a highly efficient and reliable appliance designed to meet the diverse needs of modern households. This model is primarily recognized for its robust build quality and energy-efficient performance, making it a popular choice among consumers looking for sustainability without sacrificing functionality.

One of the standout features of the Ariston 41-116-07 is its advanced heating technology. The appliance utilizes a high-performance heating element that ensures rapid heating and consistent temperature control. This means that users can enjoy hot water and comfort quickly, with minimal wait times. The innovative design also includes insulation that helps to maintain heat, reducing energy consumption and lowering utility bills.

User convenience is another hallmark of the Ariston 41-116-07. The appliance comes equipped with an intuitive control panel that allows for easy operation. The simple interface helps users to set their desired temperature and monitor performance effortlessly. Additionally, the model includes programmable settings, enabling users to schedule heating cycles according to their lifestyles, further enhancing energy savings.

Safety features are paramount in the design of the Ariston 41-116-07. The appliance includes a range of safety mechanisms such as automatic shut-off, preventing overheating and potential hazards. The built-in sensors continuously monitor the system's operation, ensuring optimal performance while safeguarding the user's home and family.

In terms of installation, the Ariston 41-116-07 excels with its compact size and flexible mounting options. It can be conveniently installed in various locations, whether in a utility room, kitchen, or bathroom, without requiring extensive modifications. This flexibility is ideal for homes with limited space or unique layouts.

Maintenance is also simplified with the Ariston 41-116-07. The appliance is designed with easy-access components, making routine maintenance or troubleshooting straightforward for the average user. This ease of care further contributes to its reputation for reliability, ensuring that the unit operates efficiently over its lifespan.

In summary, the Ariston 41-116-07 stands out for its energy efficiency, user-friendly features, safety mechanisms, versatile installation options, and low maintenance requirements. These characteristics make it a valuable addition to any modern home, catering to the needs of consumers seeking both performance and convenience in their appliances. Whether for daily use or occasional needs, the Ariston 41-116-07 guarantees satisfaction through its innovative technologies and thoughtful design.