Ariston 41-116-07 installation instructions Yes

Page 41

A

 

 

IS THE PUMP

NO

 

RUNNING?

 

YES

 

 

 

POWER T O

NO

 

THE PUMP?

 

YES

1 - CHECK THE PUMP CABLE

 

 

 

 

2 - CHECK/REPLACE P.C.B.

 

 

(CT1)

 

 

3 - CHECK THE SYSTEM

 

 

PRESSURE GAUGE IS AT

 

 

1.5 BAR

 

1 - CHECK THE OPERATION

 

 

OF THE PUMP

 

 

2 - RELEASE/REPLACE THE

 

 

PUMP

 

IS THE FAN

NO

RUNNING?

 

YES

BOILER

 

SHUTDOWN?

NO

B

INTERNAL

P.C.B. PROTECTION

ACTIVATED?

NO

POWER T O

THE FAN?

YES

1 - REPLACE THE FAN

YES 1 - RESET THE BOILER

1 - CHECK/REPLACE AIR

PRESSURE SWITCH AND CABLE

YES 2 - CHECK IF THE RESET IS JAMMED

3 - CHECK/REPLACE DETECTION ELECTRODE

 

1

- CHECK/REPLACE FAN

NO

 

CONNECTION CABLE

2

- CHECK/REPLACE P.C.B.

 

3

- CHECK/REPLACE AIR

PRESSURE SWITCH

FC002Ab

B063

17

Image 41
Contents Installation Instructions Type C Boilers Table of Contents General Information Flue connector Installation Overall Dimensions Supply must be fused at 3 a Residual Head of the Boiler Tonbridge Morley RoadKent TN9 1RA 60/100 mm80 mm Type Exhaust Restrictor Maximum Risk of Condensation FormingExtension Piping not insulated Piping insulated SystemsRoom Thermostat Connection A11 Overheat Thermostat GAS and Water Circuits H.W. Storage Cylinder Model Domestic HOT Water Priority KIT CommissioningControl Panel Combustion Analysis Turn off the boiler Liquid Butane Gas Liquid Propane Gas G30 G31 GAS AdjustmentsMethane Gas G20 Maintenance Page Manufacturer Merloni TermoSanitari SpA Italy Technical Service Hot Line 01494Technical Information Servicing Instructions Type C Boilers Fault Finding Removing the front panel Servicing InstructionsRemoving the side panels Removing the sealed chamber front coverRemoving the electrodes Removing the combustion coverRemoving the burner and jets Removing the main heat exchanger Removing the fan Removing the air pressure switchSetting the minimum and the maximum power of the boiler Setting the gas pressuresGas escaping with an approved soap and water solution Setting pressure for soft ignitionRegulating the heating power for Propane gas G31 Regulating the heating power for Natural gas G20Regulating the heating power for Butane gas G30 Removing the gas valve Removing the spark generatorRemoving the automatic air vent 1. Unscrew valve top Z FIG Removing the pump pressure switchRemoving the safety valve Removing the pump Removing the expansion vessel Removing the pressure gaugeRemoving the regulation thermostat Removing the overheat thermostatRemoving the frost thermostat O1O1 P1 P1 Checking the fuseRemoving the P.C.B.s Finding diagrams described in this chapter Fault FindingYES Mbar Electrical DiagramsSF008A MicroSYSTEM 21/28 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1550

41-116-07 specifications

The Ariston 41-116-07 is a highly efficient and reliable appliance designed to meet the diverse needs of modern households. This model is primarily recognized for its robust build quality and energy-efficient performance, making it a popular choice among consumers looking for sustainability without sacrificing functionality.

One of the standout features of the Ariston 41-116-07 is its advanced heating technology. The appliance utilizes a high-performance heating element that ensures rapid heating and consistent temperature control. This means that users can enjoy hot water and comfort quickly, with minimal wait times. The innovative design also includes insulation that helps to maintain heat, reducing energy consumption and lowering utility bills.

User convenience is another hallmark of the Ariston 41-116-07. The appliance comes equipped with an intuitive control panel that allows for easy operation. The simple interface helps users to set their desired temperature and monitor performance effortlessly. Additionally, the model includes programmable settings, enabling users to schedule heating cycles according to their lifestyles, further enhancing energy savings.

Safety features are paramount in the design of the Ariston 41-116-07. The appliance includes a range of safety mechanisms such as automatic shut-off, preventing overheating and potential hazards. The built-in sensors continuously monitor the system's operation, ensuring optimal performance while safeguarding the user's home and family.

In terms of installation, the Ariston 41-116-07 excels with its compact size and flexible mounting options. It can be conveniently installed in various locations, whether in a utility room, kitchen, or bathroom, without requiring extensive modifications. This flexibility is ideal for homes with limited space or unique layouts.

Maintenance is also simplified with the Ariston 41-116-07. The appliance is designed with easy-access components, making routine maintenance or troubleshooting straightforward for the average user. This ease of care further contributes to its reputation for reliability, ensuring that the unit operates efficiently over its lifespan.

In summary, the Ariston 41-116-07 stands out for its energy efficiency, user-friendly features, safety mechanisms, versatile installation options, and low maintenance requirements. These characteristics make it a valuable addition to any modern home, catering to the needs of consumers seeking both performance and convenience in their appliances. Whether for daily use or occasional needs, the Ariston 41-116-07 guarantees satisfaction through its innovative technologies and thoughtful design.