Ariston 41-116-07 installation instructions Supply must be fused at 3 a

Page 7

2.7GAS CONNECTION

2.8WATER CONNECTIONS

FIG. 2.4

marked “L”.

Note: The diagrams for the electrical system are indicated in section 2.12.

Warning, this appliance must be earthed.

External wiring to the appliance must be carried out by a competent person and be in accordance with the current I.E.E. Regulations and applicable local regulations. The microSYSTEM range of boilers are supplied for connection to a 230 V~ 50 Hz supply.

The supply must be fused at 3 A.

The method of connection to the electricity supply must facilitate complete electrical isolation of the appliance, by the use of a fused double pole isolator having a contact separation of at least 3 mm in all poles or alternatively, by means of a 3 A fused three pin plug and unswitched shuttered socket outlet both complying with BS 1363.

The point of connection to the Electricity supply must be readily accessible and adjacent to the appliance unless the appliance is installed in a bathroom when this must be sited outside the bathroom (see section 2.2).

The local gas region contractor connects the gas meter to the service pipe. If the gas supply for the boiler serves other appliances ensure that an adequate supply is available both to the boiler and the other appliances when they are in use at the same time.

Pipe work must be of an adequate size. Pipes of a smaller size than the boiler inlet connection should not be used.

VIEW OF THE BOILER CONNECTIONS

 

 

E

D

 

 

 

 

A

B

C

 

F

 

 

 

FIG. 2.3

 

SC004A

 

 

 

 

 

 

 

 

 

LEGEND:

A = Central Heating Flow

C = Gas Inlet

E= Central Heating Return

F= Safety Valve

G= Pump transportation screw (remove before igniting the boiler)

H= Automatic By-pass pipe

CENTRAL HEATING

Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990, the following notes are given for general guidance.

7

Image 7
Contents Installation Instructions Type C Boilers Table of Contents General Information Flue connector Installation Overall Dimensions Supply must be fused at 3 a Residual Head of the Boiler 60/100 mm Morley RoadTonbridge Kent TN9 1RA80 mm Systems Exhaust Restrictor Maximum Risk of Condensation FormingType Extension Piping not insulated Piping insulatedRoom Thermostat Connection A11 Overheat Thermostat GAS and Water Circuits H.W. Storage Cylinder Model Domestic HOT Water Priority KIT CommissioningControl Panel Combustion Analysis Turn off the boiler Methane Gas G20 GAS AdjustmentsLiquid Butane Gas Liquid Propane Gas G30 G31 Maintenance Page Technical Information Technical Service Hot Line 01494Manufacturer Merloni TermoSanitari SpA Italy Servicing Instructions Type C Boilers Fault Finding Removing the front panel Servicing InstructionsRemoving the side panels Removing the sealed chamber front coverRemoving the burner and jets Removing the combustion coverRemoving the electrodes Removing the main heat exchanger Removing the fan Removing the air pressure switchSetting pressure for soft ignition Setting the gas pressuresSetting the minimum and the maximum power of the boiler Gas escaping with an approved soap and water solutionRegulating the heating power for Butane gas G30 Regulating the heating power for Natural gas G20Regulating the heating power for Propane gas G31 Removing the gas valve Removing the spark generatorRemoving the safety valve Removing the pump pressure switchRemoving the automatic air vent 1. Unscrew valve top Z FIG Removing the pump Removing the expansion vessel Removing the pressure gaugeRemoving the frost thermostat Removing the overheat thermostatRemoving the regulation thermostat Removing the P.C.B.s Checking the fuseO1O1 P1 P1 Finding diagrams described in this chapter Fault FindingYES Mbar Electrical DiagramsSF008A MicroSYSTEM 21/28 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1550

41-116-07 specifications

The Ariston 41-116-07 is a highly efficient and reliable appliance designed to meet the diverse needs of modern households. This model is primarily recognized for its robust build quality and energy-efficient performance, making it a popular choice among consumers looking for sustainability without sacrificing functionality.

One of the standout features of the Ariston 41-116-07 is its advanced heating technology. The appliance utilizes a high-performance heating element that ensures rapid heating and consistent temperature control. This means that users can enjoy hot water and comfort quickly, with minimal wait times. The innovative design also includes insulation that helps to maintain heat, reducing energy consumption and lowering utility bills.

User convenience is another hallmark of the Ariston 41-116-07. The appliance comes equipped with an intuitive control panel that allows for easy operation. The simple interface helps users to set their desired temperature and monitor performance effortlessly. Additionally, the model includes programmable settings, enabling users to schedule heating cycles according to their lifestyles, further enhancing energy savings.

Safety features are paramount in the design of the Ariston 41-116-07. The appliance includes a range of safety mechanisms such as automatic shut-off, preventing overheating and potential hazards. The built-in sensors continuously monitor the system's operation, ensuring optimal performance while safeguarding the user's home and family.

In terms of installation, the Ariston 41-116-07 excels with its compact size and flexible mounting options. It can be conveniently installed in various locations, whether in a utility room, kitchen, or bathroom, without requiring extensive modifications. This flexibility is ideal for homes with limited space or unique layouts.

Maintenance is also simplified with the Ariston 41-116-07. The appliance is designed with easy-access components, making routine maintenance or troubleshooting straightforward for the average user. This ease of care further contributes to its reputation for reliability, ensuring that the unit operates efficiently over its lifespan.

In summary, the Ariston 41-116-07 stands out for its energy efficiency, user-friendly features, safety mechanisms, versatile installation options, and low maintenance requirements. These characteristics make it a valuable addition to any modern home, catering to the needs of consumers seeking both performance and convenience in their appliances. Whether for daily use or occasional needs, the Ariston 41-116-07 guarantees satisfaction through its innovative technologies and thoughtful design.