Ariston 41-116-07 installation instructions Combustion Analysis

Page 19

4

B

To dismantle the front casing panel it is necessary to: 1 - Remove the two screws “B”;

2 - Move the front casing panel up and lift forward.

5

4.4 I S -THE CHECKS TO BE RUN BEFORE INITIAL START-UP ARE AS FOLLOWS: NITIAL TART UP

1.Make sure that:

-the screw on the automatic air valve has been loosened when the system is full;

-If the water pressure in the system is below 1.5 bar, bring it up to the appropriate level;

-Ensure that the gas cock is closed;

-Make sure that the electrical connection has been made properly and that the earth wire is connected to an efficient earthing system;

-Supply power to the boiler by pushing the On/Off button “A” (see FIG.4.1) - the L.E.D. “B” will illuminate. Then push the button “C” in for central heating - the L.E.D. “D” will illuminate. This will start the circulation pump. After 7 seconds, the boiler will signal a shutdown due to ignition failure. Leave the boiler as it is until all of the air has been bled from the system.

-Loosen the cap on the head of the pump to eliminate any air pockets;

-Repeat the procedure for bleeding the radiators of air;

-Check the system pressure and, if it has dropped, open the filling loop again to bring the pressure back up to 1.5 bar.

2.Make sure that all gate valves are open;

3.Turn on the gas cock and check the seals on the connections with an approved soap solution and eliminate any leaks.

4.Press the reset button “E” for the lighting system; the spark will light the main burner. If the burner does not light the first time, repeat the procedure.

5.Check the minimum and maximum pressure values for the gas going to the burner; adjust it if needed using the values indicated in the table in section 5 (See the relative section for burner pressure adjustment within the servicing manual).

4.5COMBUSTION ANALYSIS

FIG. 4.2

The flue connector has two apertures, readings can be taken for the temperature of the combustion by-products and of the combustion air, as well as of the concentrations of O2 and CO2, etc. .

To access these intakes it is necessary to unscrew the front screw and remove the metal plate with sealing gasket.

To achieve the best test conditions, turn the central heating adjustment knob “G” to the “max” position and remove the electrical connection to the heating sensor (see section 6.). This will allow the appliance to operate at the maximum heating power.

19

Image 19
Contents Installation Instructions Type C Boilers Table of Contents General Information Flue connector Installation Overall Dimensions Supply must be fused at 3 a Residual Head of the Boiler 60/100 mm Morley RoadTonbridge Kent TN9 1RA80 mm Systems Exhaust Restrictor Maximum Risk of Condensation FormingType Extension Piping not insulated Piping insulatedRoom Thermostat Connection A11 Overheat Thermostat GAS and Water Circuits H.W. Storage Cylinder Model Domestic HOT Water Priority KIT CommissioningControl Panel Combustion Analysis Turn off the boiler Methane Gas G20 GAS AdjustmentsLiquid Butane Gas Liquid Propane Gas G30 G31 Maintenance Page Technical Information Technical Service Hot Line 01494Manufacturer Merloni TermoSanitari SpA Italy Servicing Instructions Type C Boilers Fault Finding Removing the front panel Servicing InstructionsRemoving the side panels Removing the sealed chamber front coverRemoving the burner and jets Removing the combustion coverRemoving the electrodes Removing the main heat exchanger Removing the fan Removing the air pressure switchSetting pressure for soft ignition Setting the gas pressuresSetting the minimum and the maximum power of the boiler Gas escaping with an approved soap and water solutionRegulating the heating power for Butane gas G30 Regulating the heating power for Natural gas G20Regulating the heating power for Propane gas G31 Removing the gas valve Removing the spark generatorRemoving the safety valve Removing the pump pressure switchRemoving the automatic air vent 1. Unscrew valve top Z FIG Removing the pump Removing the expansion vessel Removing the pressure gaugeRemoving the frost thermostat Removing the overheat thermostatRemoving the regulation thermostat Removing the P.C.B.s Checking the fuseO1O1 P1 P1 Finding diagrams described in this chapter Fault FindingYES Mbar Electrical DiagramsSF008A MicroSYSTEM 21/28 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1550

41-116-07 specifications

The Ariston 41-116-07 is a highly efficient and reliable appliance designed to meet the diverse needs of modern households. This model is primarily recognized for its robust build quality and energy-efficient performance, making it a popular choice among consumers looking for sustainability without sacrificing functionality.

One of the standout features of the Ariston 41-116-07 is its advanced heating technology. The appliance utilizes a high-performance heating element that ensures rapid heating and consistent temperature control. This means that users can enjoy hot water and comfort quickly, with minimal wait times. The innovative design also includes insulation that helps to maintain heat, reducing energy consumption and lowering utility bills.

User convenience is another hallmark of the Ariston 41-116-07. The appliance comes equipped with an intuitive control panel that allows for easy operation. The simple interface helps users to set their desired temperature and monitor performance effortlessly. Additionally, the model includes programmable settings, enabling users to schedule heating cycles according to their lifestyles, further enhancing energy savings.

Safety features are paramount in the design of the Ariston 41-116-07. The appliance includes a range of safety mechanisms such as automatic shut-off, preventing overheating and potential hazards. The built-in sensors continuously monitor the system's operation, ensuring optimal performance while safeguarding the user's home and family.

In terms of installation, the Ariston 41-116-07 excels with its compact size and flexible mounting options. It can be conveniently installed in various locations, whether in a utility room, kitchen, or bathroom, without requiring extensive modifications. This flexibility is ideal for homes with limited space or unique layouts.

Maintenance is also simplified with the Ariston 41-116-07. The appliance is designed with easy-access components, making routine maintenance or troubleshooting straightforward for the average user. This ease of care further contributes to its reputation for reliability, ensuring that the unit operates efficiently over its lifespan.

In summary, the Ariston 41-116-07 stands out for its energy efficiency, user-friendly features, safety mechanisms, versatile installation options, and low maintenance requirements. These characteristics make it a valuable addition to any modern home, catering to the needs of consumers seeking both performance and convenience in their appliances. Whether for daily use or occasional needs, the Ariston 41-116-07 guarantees satisfaction through its innovative technologies and thoughtful design.