Desa RCLP375, BCLP375 owner manual Service Procedure, Cleaning fan

Page 10

SERVICE PROCEDURE

Cleaning fan

Clean fan every 500 hours of operation or as needed.

1.Remove screws on side cover using 7,8 mm (5/16 in.) nut-driver.

2.Remove side cover.

3.Detach the five motor wires from parts under heater shell. Be sure to detach only wires coming from motor.

The five motor wires are:

white wire—to terminal board

red wire—to terminal board

blue wire—to thermal switch wire

blue wire—to solenoid valve

green wire—to grounding screw on shell

4.Remove fan guard from rear of heater.

5.Reach into rear of heater shell. Carefully pull motor wires through hole in bottom of shell. Note: Pull wires through hole one at a time.

6.Remove nuts and mounting bolts holding motor mount to shell. Use 9,5 mm (3/8") nut-driver and 11,1 mm (7/16") wrench.

7.Carefully pull motor and fan out of shell.

IMPORTANT: Be careful not to damage fan. Do not set motor and fan down with the weight resting on fan. This could damage fan pitch.

8.Turn motor and fan around. Place motor and fan into shell backwards. Note: Motor will go into shell first (see Figure 8, page 11).

10

WARNING

WARNING ICON

G 001

Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.

 

Grounding Screw

Thermal

Relay

Switch Wire

 

Terminal

Board

Solenoid

Valve

Figure 6 - Location of Motor Wires

Mounting

Bolts

Motor

Mount

Motor

Wires

Figure 7 - Location of Fan and Motor

100165

Image 10
Contents Canadian Propane Construction Heaters Contents Safety Information Unpacking RCLP375 and BCLP375 ModelsTheory of Operation Cross Section Operational ViewPropane Supply Installation Regulator With Adjustment Knob Pointing DownCheck all connections for leaks To Stop Heater Ventilation OperationTo Start Heater To Restart HeaterTrouble Shooting Maintenance Storage Disconnect heater from propane supply tanksService Procedure Cleaning fanFan and Motor Turned Around Specifications Wiring Diagram Wiring DiagramParts Under Warranty Accessories Technical Service Service PublicationsParts Not Under Warranty 100165 Warranty and Repair Service Limited WarrantyManuel D’UTILISATION Table DES Matières PAR Mesure DE SécuritéAvertissements Suite NOMEN- Clature DES Pièces Déballage Modèles RCLP375 et BCLP375Nement Coupe, fonctionnementAlimentation EN Propane Régulateur avec bouton de réglage dirigé vers le bas Fermer le robinet d’alimentation en propane Ventilation Utilisation Mise en marche de l’appareilPour arrêter l’appareil de chauffage Dépannage EntretienPour remettre l’appareil en marche Remisage Spécifications Débrancher l’appareil du ou des réservoirs de propaneProcédures ’ENTRETIEN Nettoyage du ventilateurVentilateur et moteur inversés Suite Schéma Électrique Schéma électriqueAccessoires Service Technique Publications Techniques Pièces sous garantie Pièces DE RechangePièces qui ne sont pas sous garantie Remarques Remarques Service ET Réparations Sous Garantie Garantie Limitée