VENTILATION
OPERATION
8
WARNING
WARNING ICON | G 001 |
Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
Provide at least a 0,28 m2
WARNING
WARNING ICON | G 001 |
Review and understand the warnings in the Safety Information Section, page 3. They are needed to safely operate this heater. Follow all local codes when using this heater.
To Start Heater
1.Follow all installation, ventilation, and safety information.
2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.
3.Plug power cord of heater into a
4.Plug extension cord into a 120 volt/60 hertz,
5.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly,
6.Make sure regulator is set between 48 and 138 kPa (7 and 20 psig). Note: Higher regulator setting will allow heater to produce more heat.
WARNING
WARNING ICON | G 001 |
Do not adjust regulator below 48 kPa (7 psig) or above 138 KPa (20 psig). Heater may not run properly.
7.Push start switch to start heater. Heater will start within six seconds.
Note: If heater does not start, unplug the heater. Wait ten seconds for safety control to reset, then try again.
To Stop Heater
1.Tightly close propane supply valve on propane tank(s).
2.Wait a few seconds. Heater will burn gas left in supply hoses.
3.Unplug heater.
To Restart Heater
If safety control stops gas flow to heater, motor will continue to run. To restart heater:
1.Unplug the heater. Wait ten seconds for safety control to reset.
2.Plug in heater. Push start switch.