Desa RCLP375, BCLP375 Propane Supply Installation, Regulator With Adjustment Knob Pointing Down

Page 6

PROPANE

SUPPLY

INSTALLATION

6

Propane gas and propane tank(s) are to be furnished by the user.

Use this heater only with a propane vapor withdrawal supply system.

The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount:

1.The amount of propane gas in tank(s)

2.The temperature of tank(s)

The chart below shows the number of 45-kg (100-pound) tanks needed to run this heater. Do not operate this product with any tank smaller than 45-kg (100 pounds).

 

Temperature °C (°F) At Tank

 

4,5 °C

0 °C

-6.2 °C

-17.7 °C

-23.3 °C

-28.9 °C

(40 °˚F)

(32 °F)

(20 °F)

(0 °F)

(-10 °F)

(-20 °F)

Number of tanks 3

(Use larger tank below 4,5°C [40°F])

 

Less gas is vaporized at lower temperatures. You may need a larger tank in colder weather. Your local propane gas dealer will help you select the proper supply system.

WARNING

WARNING ICON

G 001

Review and understand the warnings in the Safety Information Section, page 3. They are needed to safely operate this heater. Follow all local codes when using this heater.

WARNING

WARNING ICON

G 001

Test all gas piping and connections for leaks after installa- tion or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

1.Provide propane supply system (see Propane Supply above).

2.Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly using

2,22 cm (7/8 in.) wrench. IMPORTANT: Tighten regulator with black adjust- ment knob pointing down. Pointing adjustment knob down protects regulator from weather damage.

 

POL Fitting

Supply

Hose

Valve

 

 

Regulator

Propane

 

Tank

Adjustment

 

Knob

 

(pointing down)

Figure 3 - Regulator With Adjustment Knob Pointing Down

100165

Image 6
Contents Canadian Propane Construction Heaters Contents Safety Information Unpacking RCLP375 and BCLP375 ModelsTheory of Operation Cross Section Operational ViewPropane Supply Installation Regulator With Adjustment Knob Pointing DownCheck all connections for leaks To Stop Heater Ventilation OperationTo Start Heater To Restart HeaterTrouble Shooting Maintenance Storage Disconnect heater from propane supply tanksService Procedure Cleaning fanFan and Motor Turned Around Specifications Wiring Diagram Wiring DiagramAccessories Technical Service Service Publications Parts Under WarrantyParts Not Under Warranty 100165 Warranty and Repair Service Limited WarrantyManuel D’UTILISATION Table DES Matières PAR Mesure DE SécuritéAvertissements Suite NOMEN- Clature DES Pièces Déballage Modèles RCLP375 et BCLP375Nement Coupe, fonctionnementAlimentation EN Propane Régulateur avec bouton de réglage dirigé vers le bas Fermer le robinet d’alimentation en propane Ventilation Utilisation Mise en marche de l’appareilDépannage Entretien Pour arrêter l’appareil de chauffagePour remettre l’appareil en marche Remisage Spécifications Débrancher l’appareil du ou des réservoirs de propaneProcédures ’ENTRETIEN Nettoyage du ventilateurVentilateur et moteur inversés Suite Schéma Électrique Schéma électriqueAccessoires Service Technique Publications Techniques Pièces DE Rechange Pièces sous garantiePièces qui ne sont pas sous garantie Remarques Remarques Service ET Réparations Sous Garantie Garantie Limitée