Desa BCLP375, RCLP375 owner manual Theory of Operation, Cross Section Operational View

Page 5

THEORY OF OPERATION

The Fuel System: The hose/regulator assembly attaches to the propane gas supply. The propane gas moves through the solenoid valve and out the nozzle.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The burner control sends voltage to the ignitor. The ignitor ignites the fuel and air mixture.

The Safety Control System: This system causes the heater to shut down if the flame goes out. The motor will continue to run, but no heat is produced.

Combustion

ChamberIgnitor

Fan

Motor

Clean Heated Air Out (Front)

High Limit

Burner Control

Cool Air In (Back)

Power

Cord

Nozzle Solenoid

Valve

Hose/Regulator

Assembly

Air For Combustion

Air For Heating

Figure 2 - Cross Section Operational View

5

100165

Image 5
Contents Canadian Propane Construction Heaters Contents Safety Information RCLP375 and BCLP375 Models UnpackingCross Section Operational View Theory of OperationRegulator With Adjustment Knob Pointing Down Propane Supply InstallationCheck all connections for leaks To Start Heater Ventilation OperationTo Stop Heater To Restart HeaterDisconnect heater from propane supply tanks Trouble Shooting Maintenance StorageCleaning fan Service ProcedureFan and Motor Turned Around Specifications Wiring Diagram Wiring DiagramParts Not Under Warranty Accessories Technical Service Service PublicationsParts Under Warranty 100165 Limited Warranty Warranty and Repair ServiceManuel D’UTILISATION PAR Mesure DE Sécurité Table DES MatièresAvertissements Suite Modèles RCLP375 et BCLP375 NOMEN- Clature DES Pièces DéballageCoupe, fonctionnement NementAlimentation EN Propane Régulateur avec bouton de réglage dirigé vers le bas Fermer le robinet d’alimentation en propane Mise en marche de l’appareil Ventilation UtilisationPour remettre l’appareil en marche Dépannage EntretienPour arrêter l’appareil de chauffage Débrancher l’appareil du ou des réservoirs de propane Remisage SpécificationsNettoyage du ventilateur Procédures ’ENTRETIENVentilateur et moteur inversés Suite Schéma électrique Schéma ÉlectriqueAccessoires Service Technique Publications Techniques Pièces qui ne sont pas sous garantie Pièces DE RechangePièces sous garantie Remarques Remarques Garantie Limitée Service ET Réparations Sous Garantie