Desa BCLP375, RCLP375 owner manual Fan and Motor Turned Around

Page 11

9.Line up rear mounting holes in shell with first hole on each side of motor mount (see Figure 8). Note: When holes are lined up, fan should be outside of shell.

10.Holding mounting bolt, carefully reach through fan blades into rear of heater. Be careful not to damage fan pitch. Insert bolt through motor mount and shell. With free hand, attach nut finger tight. Repeat process for other mounting hole.

11.Use 3,1 mm (1/8") hex wrench to loosen setscrew which holds fan to motor shaft (see Figure 9).

12.Slip fan off motor shaft.

13.Clean fan using soft cloth moistened with kerosene or solvent.

14.Dry fan thoroughly.

15.Replace fan on motor shaft. Make sure setscrew is touching back of flat surface on motor shaft (see Figure 10).

16.Place setscrew on flat of shaft. Tighten setscrew firmly (4,52-5,65 [40-50 inch-pounds]).

17.Remove two nuts and bolts securing motor mount to shell.

18.Pull motor and fan from shell. Turn motor and fan around. Carefully place back in shell. Note: Fan will go into shell first.

19.Line up mounting holes in shell with holes on motor mount. Replace four bolts through shell and motor mount. Insert bolts from outside of heater. Tighten nuts firmly.

20.Route motor wires through hole in bottom of shell (see Figure 7, page 10).

Continued

Rear Mounting

Hole

First

Hole

Figure 8 - Fan and Motor Turned Around

Fan

Setscrews

Motor shaft

Figure 9 - Fan, Motor Shaft, and Setscrew Locations

Fan

Hub

 

Motor Shaft

 

Setscrews

 

Figure 10 - Fan Cross Section

11

100165

Image 11
Contents Canadian Propane Construction Heaters Contents Safety Information RCLP375 and BCLP375 Models UnpackingCross Section Operational View Theory of OperationRegulator With Adjustment Knob Pointing Down Propane Supply InstallationCheck all connections for leaks To Restart Heater Ventilation OperationTo Start Heater To Stop HeaterDisconnect heater from propane supply tanks Trouble Shooting Maintenance StorageCleaning fan Service ProcedureFan and Motor Turned Around Specifications Wiring Diagram Wiring DiagramParts Not Under Warranty Accessories Technical Service Service PublicationsParts Under Warranty 100165 Limited Warranty Warranty and Repair ServiceManuel D’UTILISATION PAR Mesure DE Sécurité Table DES MatièresAvertissements Suite Modèles RCLP375 et BCLP375 NOMEN- Clature DES Pièces DéballageCoupe, fonctionnement NementAlimentation EN Propane Régulateur avec bouton de réglage dirigé vers le bas Fermer le robinet d’alimentation en propane Mise en marche de l’appareil Ventilation UtilisationPour remettre l’appareil en marche Dépannage EntretienPour arrêter l’appareil de chauffage Débrancher l’appareil du ou des réservoirs de propane Remisage SpécificationsNettoyage du ventilateur Procédures ’ENTRETIENVentilateur et moteur inversés Suite Schéma électrique Schéma ÉlectriqueAccessoires Service Technique Publications Techniques Pièces qui ne sont pas sous garantie Pièces DE RechangePièces sous garantie Remarques Remarques Garantie Limitée Service ET Réparations Sous Garantie