Cleaning and Maintenance

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners, and cir- culatingairpassagesoffireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fire- place may need more frequent cleaning due to excessive lint from carpeting, bedding mate rial, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabra- sive household glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non-abrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circum- stances present. Refer to Removing/Replac- ing Glass Door, page 18, when removing glass door for cleaning.

WARNING: Only parts sup- pliedbythemanufacturershould be used when replacing broken or damaged glass door panel (see Replacement Parts, page 31). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 18). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replace- ment intended for this fireplace (see Replace- ment Parts, page 31 for detail on ordering). No substitutions may be made. See Remov- ing/Replacing Glass Door, page 18 for instruc- tions for replacing glass door.

WARNING: Do not block required air openings around glass or louver panels. Venti- lated compartments should be inspected and vacuumed at least once a year to prevent blockage prior to operation.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace

Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.

24

www.desatech.com

117437-01D

Image 24 Contents
Models VCB36NE and VCB36PETable of Contents Safety Product Identification Local CodesProduct Features Pre-Installation PreparationLocation and space requirements Packaging and Removal ClearancesFraming and Finishing Ceiling to Louver & Front91.4 cm 36 1/4 92.1 cm 14 3/4 37.5 cmMantel from Mantel Depth Opening14 35.6 cm Installation Precautions Venting InstallationVenting Installation Checking for Proper Venting Electrical Supply ConnectionRelilef With Strain Relief Installing Optional Controls High Altitude InstallationInstalling Optional Wall Mount Switch GWMS2 Installing Remote ReceiverInstalling and Activating the Remote Receiver Plastic Mounting ClipsRemote Receiver IgnitionMillivolt Wiring Diagram Wiring DiagramsFireplace Installation Installing Gas Piping to Fireplace LocationInstallation Items Needed Check GAS TypeConnecting Fireplace to GAS Supply Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Louver Panels and Glass DoorTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Equipment Shutoff Valve Gas Meter Gas ValveRemoving Louver Panels Spring ClipsRemoving/Replacing Glass Door Glass Panel Frame RailInstalling Logs and Glowing Embers Manual Ignition System For your safety Read before lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Optional Wireless Remote OperationElectronic Ignition System Lighting Instructions RodOptional GWMS2 ON/OFF Wall Mounted Switch Optional Hand-HeldOn/Off Series Model HRC100 Variable Control KnobPilot Assembly Air Adjustment SettingInspecting Burners Burner Flame PatternsCleaning and Maintenance Glass DoorPilot and Burners Specifications Service HintsTechnical Services Troubleshooting Observed Problem Possible Cause RemedyOr replace ODS/pilot assembly Replace gas regulator Pilot is lit or cycles during Have the vent systemLow Natural gas company Burner porting or orifice CloggedGlass soots Flame impingement on Adjust the log set so Logs Clogged burner tube Clean burner tubeOrifice, adjust air shutter Burner air adjustmentObserved Problem Possible Cause Remedy Gas leak. See Warning Statement aboveReplacement Parts AccessoriesParts Burner Assembly Complete See pages 30 Damper AssemblyWire Harness Assembly Louver AssemblyParts KEY Description QTY Warranty Keep this WarrantyLimited Warranty Vent Fireplace 07/07