1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom, unless installed as a vented appliance. See Installing Damper Clamp Accessory for Vented Operation, page 11 (Remote- Ready Models Only).

5.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ig- nite if highly heated. Inspect chimney flue for damage. If dam- aged, repair flue damper before operating heater.

6.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also, if fire- place opening has vents at the bottom, you must open the vents before operating heater.

7.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 23.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls and furniture.

9.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if enough fresh air is not available. See Air for Combustion and Ventilation, pages 5 through 7. If heater keeps shutting off, see Trouble- shooting, pages 24 through 26.

10.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this heater to cook food or burn paper or any other type of sold fuels.

12.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas control which has been under water.

13.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger).

14.Turn heater off and let cool before servicing, installing, or re- pairing. Make sure the selector switch is in the OFF position (Remote-Ready Models Only). Only a qualified service per- son should install, service, or repair heater.

15.Make sure the selector switch is in the OFF position when you are away from home for long periods of time (Remote-Ready Models Only).

16.Remote-ready heaters do not need to be connected to any ex- ternal electrical source.

17.Operating heater above elevations of 4,500 feet may cause pi- lot outage.

18.To prevent performance problems with propane/LP models, do not use propane/LP fuel tank of less than 100 lb. capacity.

19.Provide adequate clearances around air openings.

For morevisit www..com

110021-01A

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation and Clearances for VENT-FREE OperationCheck GAS Type See Between 8 Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesRemote-Ready Models Only Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Extension Plates to Base Assembly 30 Model Only Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Log #1 Ember Bed Model CSG3924NR Shown Installing LogsInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Lighting Instructions Attaching Grate to Base AssemblyOperating Heater Adding Lava RockTo Turn OFF GAS to Appliance Shutting Off HeaterShutting Off Burners Only pilot stays lit Manual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingThermostat Control Operation Control Knob Rear Burner Ghrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationInspecting Burners Pilot Flame PatternBurner Flame Patterns Cleaning Maintenance Cleaning Burner Injector Holders and Pilot AIR Inlet HolesLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbTechnical Service SpecificationsWiring Diagram Service HintsFor more Visit www Com Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED VRL24NT, VRL24PT VRL30NT, VRL30PT THERMOSTAT-CONTROLLED Parts ListCSG3924NR, CSG3924PR CTB3924NR, CTB3924PR REMOTE-READY VRL24NR, VRL24PR VRL30NR, VRL30PRREMOTE-READY Accessories Replacement PartsOwners Registration Form Postage Required 110021-01A Not a UPC

VRL30NT, VRL24PT, CSG3924NT, VRL30PT, VRL24NT specifications

Desa VRL24NR, VRL24PR, VRL30NR, VRL30PR, CSG3924NR, CSG3924PR, CTB3924NR, CTB3924PR, VRL24NT, VRL24PT, VRL30NT, VRL30PT, CSG3924NT, CSG3924PT, CTB3924NT, and CTB3924PT are a series of innovative heating solutions that cater to various residential and commercial needs. These models are designed to provide efficient, reliable, and aesthetically pleasing heating options.

One of the key features across these models is their advanced heating technology. They utilize cutting-edge infrared heating systems that ensure consistent and effective warmth. This technology not only heats up spaces quickly but also provides energy savings compared to traditional heating methods. Additionally, many models are equipped with programmable thermostats allowing users to set their desired temperature and schedule, enhancing convenience and energy efficiency.

Another hallmark of these models is their versatility in installation. The options for both vent-free and vented designs provide flexibility for various environments. Users can choose vented models for additional safety and air quality control, or opt for vent-free units that are easier to install in areas without existing ventilation systems. The range of configurations helps accommodate different space sizes and heating requirements.

In terms of design, the Desa heating solutions are crafted with aesthetics in mind. Many models feature sleek exteriors and elegant finishes, making them suitable for integration into modern or traditional interior designs. This commitment to design ensures that users do not have to sacrifice style for functionality.

Durability and reliability are emphasized throughout the line. Constructed with high-quality materials, these models are built to withstand the test of time and can function effectively under varying environmental conditions. Users can have peace of mind with warranties and support from the manufacturer.

Safety is another crucial aspect of these heating solutions. Each model is designed with safety features like automatic shut-off systems, making them safe for family use even in occupied living spaces.

In summary, the Desa VRL and CSG series offers a broad selection of heating solutions characterized by advanced infrared technology, versatile installation options, stylish designs, and robust safety measures. Whether for residential or commercial purposes, these models are engineered to meet diverse heating needs efficiently and reliably.