Desa VRL30NT Product Identification, Optional Remote Control Accessories, Local Codes, Unpacking

Page 4

4

PRODUCT IDENTIFICATION

OPTIONAL REMOTE CONTROL ACCESSORIES LOCAL CODES

UNPACKING

PRODUCT IDENTIFICATION

Log Set (Varies

According to Model)

Grate

Piezo

Ignitor

Burner

Control Knob

Base

Front and Rear Assembly

Burner Control

Knob

Thermostat Models: CSG3924NT, CSG3924PT, CTB3924NT, CTB3924PT, VRL24NT, VRL24PT, VRL30NT, VRL30PT

 

Base Extension

Grate

(30" Models Only)

Pilot

Selector

Switch

Assembly

(Optional)

 

Rear

 

 

 

 

Burner

ON/OFF/

 

 

PILOT Knob

 

 

Piezo Ignitor

 

 

Front

Middle

Base Extension

(30" Models

Burner

Burner

Only)

Remote Control

 

Front and Rear

 

(Optional)

Base Assembly

 

Burner Control

 

Knob

Remote-Ready Models: CSG3924NR, CSG3924PR, CTB3924NR, CTB3924PR, VRL24NR, VRL24PR, VRL30NR, VRL30PR

Figure 1 - Product Identification

OPTIONAL REMOTE CONTROL ACCESSORIES

There are four optional remote controls that can be purchased separately for Remote-Ready Models Only:

wall switch

hand-held ON/OFF remote

wall thermostat

hand-held thermostat remote.

See Accessories, page 34.

The wall thermostat or hand-held thermostat may not be used where vented decorative listing is required.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

UNPACKING

CAUTION: Do not remove the data plates from the base assembly. The data plates contain important warranty and safety information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by the sides of assembly.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

For..com

110021-01A

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Optional Remote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type Minimum Noncombustible Material Clearances See Between 8Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Remote-Ready Models OnlyConnecting to GAS Supply Attaching Extension Plates to Base Assembly 30 Model OnlyExternal Regulator With Vent Pointing Down Pressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Installing Logs Installing Log #1 Ember Bed Model CSG3924NR ShownInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Attaching Grate to Base Assembly Operating HeaterAdding Lava Rock Lighting InstructionsShutting Off Heater To Turn OFF GAS to ApplianceShutting Off Burners Only pilot stays lit REMOTE-READY Models For Your Safety Read Before Lighting Manual Lighting ProcedureThermostat Control Operation Control Knob Rear Burner Optional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationPilot Flame Pattern Inspecting BurnersBurner Flame Patterns Cleaning Burner Injector Holders and Pilot AIR Inlet Holes Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillarySpecifications Wiring DiagramService Hints Technical ServiceIllustrated Parts Breakdown For more Visit www ComTHERMOSTAT-CONTROLLED VRL24NT, VRL24PT VRL30NT, VRL30PT Parts List THERMOSTAT-CONTROLLEDREMOTE-READY VRL24NR, VRL24PR VRL30NR, VRL30PR CSG3924NR, CSG3924PR CTB3924NR, CTB3924PRREMOTE-READY Replacement Parts AccessoriesOwners Registration Form Postage Required 110021-01A Not a UPC

VRL30NT, VRL24PT, CSG3924NT, VRL30PT, VRL24NT specifications

Desa VRL24NR, VRL24PR, VRL30NR, VRL30PR, CSG3924NR, CSG3924PR, CTB3924NR, CTB3924PR, VRL24NT, VRL24PT, VRL30NT, VRL30PT, CSG3924NT, CSG3924PT, CTB3924NT, and CTB3924PT are a series of innovative heating solutions that cater to various residential and commercial needs. These models are designed to provide efficient, reliable, and aesthetically pleasing heating options.

One of the key features across these models is their advanced heating technology. They utilize cutting-edge infrared heating systems that ensure consistent and effective warmth. This technology not only heats up spaces quickly but also provides energy savings compared to traditional heating methods. Additionally, many models are equipped with programmable thermostats allowing users to set their desired temperature and schedule, enhancing convenience and energy efficiency.

Another hallmark of these models is their versatility in installation. The options for both vent-free and vented designs provide flexibility for various environments. Users can choose vented models for additional safety and air quality control, or opt for vent-free units that are easier to install in areas without existing ventilation systems. The range of configurations helps accommodate different space sizes and heating requirements.

In terms of design, the Desa heating solutions are crafted with aesthetics in mind. Many models feature sleek exteriors and elegant finishes, making them suitable for integration into modern or traditional interior designs. This commitment to design ensures that users do not have to sacrifice style for functionality.

Durability and reliability are emphasized throughout the line. Constructed with high-quality materials, these models are built to withstand the test of time and can function effectively under varying environmental conditions. Users can have peace of mind with warranties and support from the manufacturer.

Safety is another crucial aspect of these heating solutions. Each model is designed with safety features like automatic shut-off systems, making them safe for family use even in occupied living spaces.

In summary, the Desa VRL and CSG series offers a broad selection of heating solutions characterized by advanced infrared technology, versatile installation options, stylish designs, and robust safety measures. Whether for residential or commercial purposes, these models are engineered to meet diverse heating needs efficiently and reliably.