Desa CTB3924PT, VRL24NT Installing Logs, Installing Log #1 Ember Bed Model CSG3924NR Shown

Page 15

INSTALLATION

Installing Logs

15

INSTALLATION

Continued

INSTALLING LOGS

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically there- after, check to ensure that no yellow flame comes in contact with any log. With the heater set to HI, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Yellow flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. Before installing logs, make sure log alignment screws are in place and straight.

Log #3

Log #2

Log #1

Figure 21 - Installing Log #2 (Right) and Log #3 (Left) (Model CSG3924NR Shown)

Models CSG3924NT, CSG3924PT, CSG3924NR,

CSG3924PR, CTB3924NT, CTB3924PT, CTB3924NR

and CTB3924PR

1.Place log #1 (ember bed) onto base. Position log over alignment screws to left of front burner and behind middle burner. Ember bed will sit on top of front and middle burners (see Figure 20).

2.Place log #2 to the right of log #1. Log #2 will wrap around right end of rear burner and sit on two log alignment screws (see Figure 21).

3.Place log #3 on left side of base and onto alignment screw shown in Figure 21, to left of rear burner. Log #3 will wrap around left end of rear burner.

4.Place log #4 onto two alignment screws to the rear of base (see Figure 22).

5.Place log #5 over knob on log #4 and across back part of log #1 and touch log #2 (see Figure 23).

6.Place log #6 onto two pin on log #1 (ember bed) and rest back of log #6 on back log #4 (see Figure 23).

Log #1

Figure 20 - Installing Log #1 [Ember Bed]

(Model CSG3924NR Shown)

Log #4

Log #3

Log #1

Log #2

Figure 22 - Installing Log #4 (Model CSG3924NR Shown)

Log #6

Log #5

Log #3

Log #4

Log #1

Log #2

Figure 23 - Installing Log #5 (Right) and Log #6 (Left) (Model CSG3924NR Shown)

For morevisit www..com

110021-01A

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation and Clearances for VENT-FREE OperationCheck GAS Type See Between 8 Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesRemote-Ready Models Only Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Extension Plates to Base Assembly 30 Model Only Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Log #1 Ember Bed Model CSG3924NR Shown Installing LogsInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Lighting Instructions Attaching Grate to Base AssemblyOperating Heater Adding Lava RockTo Turn OFF GAS to Appliance Shutting Off HeaterShutting Off Burners Only pilot stays lit Manual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingThermostat Control Operation Control Knob Rear Burner Ghrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationInspecting Burners Pilot Flame PatternBurner Flame Patterns Cleaning Maintenance Cleaning Burner Injector Holders and Pilot AIR Inlet HolesLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbTechnical Service SpecificationsWiring Diagram Service HintsFor more Visit www Com Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED VRL24NT, VRL24PT VRL30NT, VRL30PT THERMOSTAT-CONTROLLED Parts ListCSG3924NR, CSG3924PR CTB3924NR, CTB3924PR REMOTE-READY VRL24NR, VRL24PR VRL30NR, VRL30PRREMOTE-READY Accessories Replacement PartsOwners Registration Form Postage Required 110021-01A Not a UPC

VRL30NT, VRL24PT, CSG3924NT, VRL30PT, VRL24NT specifications

Desa VRL24NR, VRL24PR, VRL30NR, VRL30PR, CSG3924NR, CSG3924PR, CTB3924NR, CTB3924PR, VRL24NT, VRL24PT, VRL30NT, VRL30PT, CSG3924NT, CSG3924PT, CTB3924NT, and CTB3924PT are a series of innovative heating solutions that cater to various residential and commercial needs. These models are designed to provide efficient, reliable, and aesthetically pleasing heating options.

One of the key features across these models is their advanced heating technology. They utilize cutting-edge infrared heating systems that ensure consistent and effective warmth. This technology not only heats up spaces quickly but also provides energy savings compared to traditional heating methods. Additionally, many models are equipped with programmable thermostats allowing users to set their desired temperature and schedule, enhancing convenience and energy efficiency.

Another hallmark of these models is their versatility in installation. The options for both vent-free and vented designs provide flexibility for various environments. Users can choose vented models for additional safety and air quality control, or opt for vent-free units that are easier to install in areas without existing ventilation systems. The range of configurations helps accommodate different space sizes and heating requirements.

In terms of design, the Desa heating solutions are crafted with aesthetics in mind. Many models feature sleek exteriors and elegant finishes, making them suitable for integration into modern or traditional interior designs. This commitment to design ensures that users do not have to sacrifice style for functionality.

Durability and reliability are emphasized throughout the line. Constructed with high-quality materials, these models are built to withstand the test of time and can function effectively under varying environmental conditions. Users can have peace of mind with warranties and support from the manufacturer.

Safety is another crucial aspect of these heating solutions. Each model is designed with safety features like automatic shut-off systems, making them safe for family use even in occupied living spaces.

In summary, the Desa VRL and CSG series offers a broad selection of heating solutions characterized by advanced infrared technology, versatile installation options, stylish designs, and robust safety measures. Whether for residential or commercial purposes, these models are engineered to meet diverse heating needs efficiently and reliably.