Desa VRL30NT, VRL24NT, CTB3924PT, CSG3924NT To Turn OFF GAS to Appliance, Shutting Off Heater

Page 18

18

OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS)

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

OPERATING HEATER

Continued

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

Ignitor Button

Control Knob

 

Rear Burner

 

Control Knob

Models: CSG3924NT, CSG3924PT, VRL24NT, VRL24PT, VRL30NT and VRL30PT

1.STOP! Read the safety information on page 17, column 2.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, page 17, column 2. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 29).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

6.With thermostat control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 19.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The front burner should light. Set control knob to any heat level between HI and LO.

9.To light the rear yellow flame burner, push in and turn

rear burner control knob counterclockwise to the ON position.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Figure 29 - Control Knob(s) and Ignitor Button Locations

Pilot Burner

 

Ignitor Electrode

Ignitor

Thermocouple

Thermocouple

Electrode

Pilot Burner

Figure 30 - Pilot (Propane/LP) Figure 31 - Pilot (Natural)

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn rear burner control knob clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1.Turn control knob clockwise to the PILOT position.

2.Turn rear burner control knob clockwise to the OFF position.

For..com

110021-01A

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Local Codes Optional Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation and Clearances for VENT-FREE OperationCheck GAS Type Minimum Noncombustible Material Clearances See Between 8Floor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Remote-Ready Models OnlyConnecting to GAS Supply Attaching Extension Plates to Base Assembly 30 Model OnlyExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Installing Log #1 Ember Bed Model CSG3924NR ShownInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Adding Lava Rock Attaching Grate to Base AssemblyOperating Heater Lighting InstructionsTo Turn OFF GAS to Appliance Shutting Off HeaterShutting Off Burners Only pilot stays lit Manual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingThermostat Control Operation Control Knob Rear Burner Ghrc Series Operation Optional Remote OperationThermostat Control Operation Ghrcta Series OperationInspecting Burners Pilot Flame PatternBurner Flame Patterns Cleaning Maintenance Cleaning Burner Injector Holders and Pilot AIR Inlet HolesLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillaryService Hints SpecificationsWiring Diagram Technical ServiceIllustrated Parts Breakdown For more Visit www ComTHERMOSTAT-CONTROLLED VRL24NT, VRL24PT VRL30NT, VRL30PT Parts List THERMOSTAT-CONTROLLEDREMOTE-READY VRL24NR, VRL24PR VRL30NR, VRL30PR CSG3924NR, CSG3924PR CTB3924NR, CTB3924PRREMOTE-READY Replacement Parts AccessoriesOwners Registration Form Postage Required 110021-01A Not a UPC