Desa CSG3924NT, VRL24NT, CTB3924PT, VRL24PT, VRL30NT, VRL30PT Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

PRODUCT IDENTIFICATION

4

OPTIONAL REMOTE CONTROL ACCESSORIES

4

LOCAL CODES

4

UNPACKING

4

PRODUCT FEATURES

5

AIR FOR COMBUSTION AND VENTILATION

5

INSTALLATION

8

OPERATING HEATER

17

INSPECTING BURNERS

22

CLEANING AND MAINTENANCE

23

TROUBLESHOOTING

24

OPTIONAL POSITIONING OF

 

THERMOSTAT SENSING BULB

27

SPECIFICATIONS

28

WIRING DIAGRAM

28

SERVICE HINTS

28

TECHNICAL SERVICE

28

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

29

REPLACEMENT PARTS

34

ACCESSORIES

34

OWNER’S REGISTRATION FORM

35

SAFETY INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this heater. Improper use of this heater can cause property damage and serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and Propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its con- trols can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this heater.

WARNING: This appliance is for installation only in a solid-fuel burning fireplace or approved ventless firebox enclosure.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes very hot when run- ning heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

Carefully supervise young children when they are in the room with heater. When using the hand-held remote accessory (Remote-Ready Models Only), keep selector switch in the OFF position to prevent chil- dren from turning on burners with remote.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

For..com

110021-01A

Image 2
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Local Codes Optional Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation Minimum Noncombustible Material Clearances See Between 8Floor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Remote-Ready Models OnlyConnecting to GAS Supply Attaching Extension Plates to Base Assembly 30 Model OnlyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Logs Installing Log #1 Ember Bed Model CSG3924NR ShownInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Adding Lava Rock Attaching Grate to Base AssemblyOperating Heater Lighting InstructionsShutting Off Burners Only pilot stays lit To Turn OFF GAS to ApplianceShutting Off Heater Thermostat Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Control Knob Rear Burner Ghrc Series Operation Optional Remote OperationThermostat Control Operation Ghrcta Series OperationBurner Flame Patterns Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillaryService Hints SpecificationsWiring Diagram Technical ServiceIllustrated Parts Breakdown For more Visit www ComTHERMOSTAT-CONTROLLED VRL24NT, VRL24PT VRL30NT, VRL30PT Parts List THERMOSTAT-CONTROLLEDREMOTE-READY VRL24NR, VRL24PR VRL30NR, VRL30PR CSG3924NR, CSG3924PR CTB3924NR, CTB3924PRREMOTE-READY Replacement Parts AccessoriesOwners Registration Form Postage Required 110021-01A Not a UPC

VRL30NT, VRL24PT, CSG3924NT, VRL30PT, VRL24NT specifications

Desa VRL24NR, VRL24PR, VRL30NR, VRL30PR, CSG3924NR, CSG3924PR, CTB3924NR, CTB3924PR, VRL24NT, VRL24PT, VRL30NT, VRL30PT, CSG3924NT, CSG3924PT, CTB3924NT, and CTB3924PT are a series of innovative heating solutions that cater to various residential and commercial needs. These models are designed to provide efficient, reliable, and aesthetically pleasing heating options.

One of the key features across these models is their advanced heating technology. They utilize cutting-edge infrared heating systems that ensure consistent and effective warmth. This technology not only heats up spaces quickly but also provides energy savings compared to traditional heating methods. Additionally, many models are equipped with programmable thermostats allowing users to set their desired temperature and schedule, enhancing convenience and energy efficiency.

Another hallmark of these models is their versatility in installation. The options for both vent-free and vented designs provide flexibility for various environments. Users can choose vented models for additional safety and air quality control, or opt for vent-free units that are easier to install in areas without existing ventilation systems. The range of configurations helps accommodate different space sizes and heating requirements.

In terms of design, the Desa heating solutions are crafted with aesthetics in mind. Many models feature sleek exteriors and elegant finishes, making them suitable for integration into modern or traditional interior designs. This commitment to design ensures that users do not have to sacrifice style for functionality.

Durability and reliability are emphasized throughout the line. Constructed with high-quality materials, these models are built to withstand the test of time and can function effectively under varying environmental conditions. Users can have peace of mind with warranties and support from the manufacturer.

Safety is another crucial aspect of these heating solutions. Each model is designed with safety features like automatic shut-off systems, making them safe for family use even in occupied living spaces.

In summary, the Desa VRL and CSG series offers a broad selection of heating solutions characterized by advanced infrared technology, versatile installation options, stylish designs, and robust safety measures. Whether for residential or commercial purposes, these models are engineered to meet diverse heating needs efficiently and reliably.