Heat & Glo LifeStyle 8000TV-OAK-IPI Troubleshooting, Standing Pilot Ignition System

Page 34

14 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

A. Standing Pilot Ignition System

Symptom

Possible Causes

Corrective Action

 

 

 

1. After repeated triggering

a. Defective ignitor.

Check the spark at the electrode and pilot. If no spark and electrode

of the red or black piezo

 

wire is properly connected, replace the ignitor.

ignitor button, the spark

 

 

b. Defective pilot or misaligned

Using match, light the pilot. If the pilot lights, turn off the pilot and

ignitor will not light the pilot.

 

electrode (spark at electrode).

trigger the red piezo ignitor button again. If the pilot lights, an im-

 

 

proper gas/air mixture caused the bad lighting and a longer purge

 

 

period is recommended. If the pilot will not light, ensure the gap

 

 

at the electrode and pilot is one-eighth (1/8) inch to have a strong

 

 

spark. If the gap is OK, replace the pilot.

 

 

 

 

c. No gas or low gas pressure.

Check the remote shut-off valves from the fireplace. Usually, there

 

 

is a valve near the gas main. There can be more than one (1) valve

 

 

between the fireplace and the main.

 

 

 

 

d. No LP in tank.

Check the LP (propane) tank. You may be out of fuel.

 

 

 

2. The pilot will not stay lit

a. Defective thermocouple.

Check that the pilot flame impinges on the thermocouple. Clean

after carefully following the

 

and/or adjust the pilot for maximum flame impingement.

lighting instructions.

 

Ensure that the thermocouple connection at the gas valve is fully

 

 

 

 

inserted and tight (hand tighten plus 1/4 turn).

 

 

Disconnect the thermocouple from the valve, place one millivolt

 

 

meter lead wire on the tip of the thermcouple and the other meter

 

 

lead wire on the thermocouple copper lead. Start the pilot and hold

 

 

the valve knob in. If the millivolt reading is less than 15mV, replace

 

 

the thermocouple.

 

 

 

 

b. Defective valve.

If the thermocouple is producing more than 15 millivolts, replace

 

 

faulty valve.

 

 

 

3. The pilot is burning,

a. ON/OFF switch or wires

Check the ON/OFF switch and wires for proper connections. Place

there is no burner flame,

defective.

the jumper wires across the terminals at the switch. If the burner

the valve knob is in the ON

 

comes on, replace the defective switch. If the switch is OK, place the

position, and the ON/OFF

 

jumper wires across the switch wires at the gas valve. If the burner

switch is in the ON position.

 

comes on, the wires are faulty or connections are bad.

 

 

 

 

b. Thermopile may not be gener-

If the pilot flame is not close enough physically to the thermopile,

 

ating sufficient millivoltage.

adjust the pilot flame.

 

 

Be sure the wire connections from the thermopile at the gas valve

 

 

terminals are tight and that the thermopile is fully inserted into the

 

 

pilot bracket.

 

 

Check the thermopile with a millivolt meter. Take the reading at

 

 

TH-TP&TP terminals of the gas valve. The meter should read 325

 

 

millivolts minimum, while holding the valve knob depressed in the

 

 

pilot position, with the pilot lit, and the ON/OFF switch in the OFF

 

 

position. Replace the faulty thermopile if the reading is below the

 

 

specified minimum.

 

 

With the pilot in the ON position, disconnect the thermopile leads

 

 

from the valve. Take a reading at the thermopile leads. The read-

 

 

ing should be 325 millivolts minimum. Replace the thermopile if the

 

 

reading is below the minimum.

 

 

 

34

Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI2058-900 Rev. L • 08/08

Image 34
Contents Models 8000TV-OAK 8000TV-OAK-IPI 8000TVLP-OAKIPI Congratulations Homeowner Reference InformationTable of Contents Appliance Certification High Altitude InstallationsListing and Code Approvals Glass SpecificationsElectrical Codes Non-Combustible Materials SpecificationCombustible Materials Specification Code CSA C22.1Design and Installation Considerations Getting StartedNegative Pressure Tools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Clearances to mantels or other combustibles above applianceTermination Locations Vent Termination Minimum ClearancesVent System Configuration Vent Information and DiagramsVent Guidelines Models Pipe SizeMaximum Horizontal Feet Minimum Vertical 9 Feet Pipe Clearances to Combustibles Vent Clearances and FramingVertical Penetration Framing Gas and Electrical Connections Installing Outside Air Kit Damper AssemblyAppliance Preparation Securing and Leveling ApplianceCompleting Grate Set-up Checking Pilot PlateSecuring Vent Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to FireboxFuel Conversions Gas Connection Gas InformationGas Pressures High Altitude Installations Wall Switch Recommendation for WireConnecting to the Appliance Electrical InformationIntellifire Ignition System Wiring Optional Accessories RequirementsStanding Pilot Ignition System Wiring Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Log Assembly LOGS-8OAK Positioning the LogsPage Screen Mesh Glass AssemblyShutter Settings Grilles and TrimCheck Appliance Draft Operating InstructionsBefore Lighting Appliance Before operating this appliance have a qualified technicianLighting Appliance IPI Ignition Final inspection byFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Sympton Possible Cause Corrective Actionflame has been lit, flame Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsService Parts Log Set AssemblyPart number list on following Stocked Service Parts ListAt Depot IPI Valve Assembly 8000TV-OAK-IPIStanding Pilot Valve Assembly 8000TV-OAKLimited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual

8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI specifications

The Heat & Glo LifeStyle 8000TVLP-OAKIPI, 8000TV-OAK-IPI, and 8000TV-OAK are cutting-edge fireplace units that redefine the way we experience warmth and ambiance in our homes. Designed with a sleek and modern aesthetic, these gas fireplaces offer an ideal blend of style, comfort, and efficiency.

One of the standout features of the LifeStyle 8000 series is its expansive viewing area, which allows homeowners to enjoy an unobstructed view of the flickering flames. The large glass display not only enhances the visual appeal but also creates a welcoming atmosphere in any living space. The unit's clean lines and contemporary design ensure it complements a wide range of interior styles, from traditional to modern.

Efficiency is a hallmark of the LifeStyle 8000 series. Equipped with advanced heating technologies, these fireplaces provide effective warmth while utilizing fuel efficiently. The patented IntelliFire technology allows for easy ignition and reliable performance. Users can enjoy the convenience of controlled heat settings, ensuring that their space remains comfortable without excessive energy use.

Moreover, the LifeStyle series incorporates innovative safety features that provide peace of mind. With automatic shut-off options, homeowners can relax knowing that the fireplace will operate safely and efficiently. The removable mesh screen adds an extra layer of security while allowing families to enjoy the ambiance without worry.

Customization is another key aspect of the Heat & Glo LifeStyle 8000 series. Homeowners can choose from a variety of finishes, making it easy to match their fireplace to their home’s decor. Options for decorative media, such as glass and logs, allow users to create a look that suits their personal style.

Installation is made simple with the flexible venting options provided by these units. The designers have prioritized user-friendliness by ensuring that the units can fit into a variety of spaces, making them an excellent choice for both new builds and renovations.

In summary, the Heat & Glo LifeStyle 8000TVLP-OAKIPI, 8000TV-OAK-IPI, and 8000TV-OAK are impressive gas fireplaces that combine efficiency, safety, and aesthetic appeal. With their high-quality construction, advanced technology, and customizable features, they offer a luxurious and practical solution for any home seeking warmth and ambiance.