Heat & Glo LifeStyle 8000TVLP-OAKIPI Troubleshooting, Symptom Possible Cause Corrective Action

Page 35

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. Continued

c. Defective valve.

Turn the valve knob to the ON position. Place the

 

 

ON/OFF switch in the ON position. Check the millivolt

 

 

meter a the thermopile terminals. The millivolt meter

 

 

should read greater than 125mV. If the reading is ac-

 

 

ceptable, and if the burner does not come on, replace

 

 

the gas valve.

 

 

 

 

d. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stop-

 

 

page.

 

 

 

 

e. Wall switch or wires are defective.

Follow the corrective action in Symptom and Pos-

 

 

sible Cause 1.a above. Check the switch and wiring.

 

 

Replace where defective.

 

 

 

4. Frequent pilot outage

a. Pilot flame may be too high or too low, or blow-

Clean thermocouple and adjust the pilot flame for

problem.

ing out (high pressure), causing pilot safety to drop

maximum flame impingement. Follow lighting instruc-

 

out.

tions carefully.

 

 

 

5. The pilot and main

a. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while

 

 

b. Inner vent pipe leaking exhaust gases back into

Check venting system for damage. Replace/repair

in operation.

the system.

improperly assembled pipe sections.

 

 

 

 

 

c. Glass too loose and air tight packet leaks in

Replace glass panel assembly.

 

corners after usage.

 

 

 

 

 

d. Bad thermopile or thermocouple.

Replace if necessary.

 

 

 

 

e. Improper vent cap installation.

Check for proper installation and freedom from debris

 

 

or blockage.

 

 

 

6. Glass soots.

a. Flame impingement.

Adjust the log set so that the flame does not exces-

 

 

sively impinge on it.

 

 

 

 

b. Improper air shutter setting.

Adjust the air shutter located on the control panel.

 

 

 

 

c. Debris around air shutter.

Inspect the opening at the base of the burner. NO MA-

 

 

TERIAL SHOULD BE PLACED IN THIS OPENING.

 

 

 

7. Flame burns blue

a. Insufficient oxygen being supplied.

Ensure that the vent cap is installed properly and free

and lifts off burner.

 

of debris. Ensure that the vent system joints are tight

 

 

and have no leaks.

 

 

Ensure that no debris has been placed at the base of,

 

 

or in the area of the air holes in the center of the base

 

 

pan beneath the burner.

 

 

Ensure that the glass is tightened properly on the unit,

 

 

particularly on top corners.

 

 

 

Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI2058-900 Rev. L • 08/08

35

Image 35
Contents Models 8000TV-OAK 8000TV-OAK-IPI 8000TVLP-OAKIPI Homeowner Reference Information CongratulationsTable of Contents Glass Specifications High Altitude InstallationsListing and Code Approvals Appliance CertificationCode CSA C22.1 Non-Combustible Materials SpecificationCombustible Materials Specification Electrical CodesGetting Started Design and Installation ConsiderationsNegative Pressure Inspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to mantels or other combustibles above appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsModels Pipe Size Vent Information and DiagramsVent Guidelines Vent System ConfigurationMaximum Horizontal Feet Minimum Vertical 9 Feet Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Securing and Leveling Appliance Installing Outside Air Kit Damper AssemblyAppliance Preparation Gas and Electrical ConnectionsChecking Pilot Plate Completing Grate Set-upAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Securing Vent SectionsGas Pressures Gas InformationFuel Conversions Gas Connection High Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Wall SwitchOptional Accessories Requirements Intellifire Ignition System WiringIntellifire Pilot Ignition IPI Wiring Diagram Standing Pilot Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Positioning the Logs Log Assembly LOGS-8OAKPage Grilles and Trim Glass AssemblyShutter Settings Screen MeshBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Check Appliance DraftFinal inspection by Lighting Appliance IPI IgnitionStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingSympton Possible Cause Corrective Action Intellifire Ignition Systemflame has been lit, flame Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramPart number list on following Log Set AssemblyService Parts At Depot Service Parts ListStocked 8000TV-OAK-IPI IPI Valve Assembly8000TV-OAK Standing Pilot Valve AssemblyLimited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information

8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI specifications

The Heat & Glo LifeStyle 8000TVLP-OAKIPI, 8000TV-OAK-IPI, and 8000TV-OAK are cutting-edge fireplace units that redefine the way we experience warmth and ambiance in our homes. Designed with a sleek and modern aesthetic, these gas fireplaces offer an ideal blend of style, comfort, and efficiency.

One of the standout features of the LifeStyle 8000 series is its expansive viewing area, which allows homeowners to enjoy an unobstructed view of the flickering flames. The large glass display not only enhances the visual appeal but also creates a welcoming atmosphere in any living space. The unit's clean lines and contemporary design ensure it complements a wide range of interior styles, from traditional to modern.

Efficiency is a hallmark of the LifeStyle 8000 series. Equipped with advanced heating technologies, these fireplaces provide effective warmth while utilizing fuel efficiently. The patented IntelliFire technology allows for easy ignition and reliable performance. Users can enjoy the convenience of controlled heat settings, ensuring that their space remains comfortable without excessive energy use.

Moreover, the LifeStyle series incorporates innovative safety features that provide peace of mind. With automatic shut-off options, homeowners can relax knowing that the fireplace will operate safely and efficiently. The removable mesh screen adds an extra layer of security while allowing families to enjoy the ambiance without worry.

Customization is another key aspect of the Heat & Glo LifeStyle 8000 series. Homeowners can choose from a variety of finishes, making it easy to match their fireplace to their home’s decor. Options for decorative media, such as glass and logs, allow users to create a look that suits their personal style.

Installation is made simple with the flexible venting options provided by these units. The designers have prioritized user-friendliness by ensuring that the units can fit into a variety of spaces, making them an excellent choice for both new builds and renovations.

In summary, the Heat & Glo LifeStyle 8000TVLP-OAKIPI, 8000TV-OAK-IPI, and 8000TV-OAK are impressive gas fireplaces that combine efficiency, safety, and aesthetic appeal. With their high-quality construction, advanced technology, and customizable features, they offer a luxurious and practical solution for any home seeking warmth and ambiance.