Heat & Glo LifeStyle 8000TV-OAK-IPI, 8000TVLP-OAKIPI Inspect Maintenance Tasks, Doors, Surrounds

Page 39

Inspect

 

Maintenance Tasks

 

 

 

Doors, Surrounds

1.

Assess condition of screen and replace as necessary. Recommend addition of screen if one is not present.

and Fronts

 

 

2.

Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

 

3.

Verify no obstructions to airflow through the louvers.

 

 

 

 

4.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment components are

 

 

intact and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

 

 

 

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw

and Firebox Top

 

tips that have penetrated the sheet metal are sharp and should be avoided.

 

 

 

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

 

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

 

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.

 

 

 

 

2.

Replace appliance if firebox has been perforated.

 

 

 

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

 

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Verify air shutter is clear of dust and debris.

 

 

 

 

7.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

8.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

9.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

 

10.

Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery

 

 

cloth or replace as required.

 

 

 

11. Verify millivolt output. Replace as necessary.

 

 

 

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or

 

 

sheds) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

 

 

6.

Inspect draft shield to verify it is not bent, damaged or missing.

 

 

 

Remote controls

1.

Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

 

3.

Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure

 

 

or leaking.

Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI2058-900 Rev. L • 08/08

39

Image 39
Contents Models 8000TV-OAK 8000TV-OAK-IPI 8000TVLP-OAKIPI Homeowner Reference Information CongratulationsTable of Contents Glass Specifications High Altitude InstallationsListing and Code Approvals Appliance CertificationCode CSA C22.1 Non-Combustible Materials SpecificationCombustible Materials Specification Electrical CodesGetting Started Design and Installation ConsiderationsNegative Pressure Inspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to mantels or other combustibles above appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsModels Pipe Size Vent Information and DiagramsVent Guidelines Vent System ConfigurationMaximum Horizontal Feet Minimum Vertical 9 Feet Vent Clearances and Framing Pipe Clearances to CombustiblesVertical Penetration Framing Securing and Leveling Appliance Installing Outside Air Kit Damper AssemblyAppliance Preparation Gas and Electrical ConnectionsChecking Pilot Plate Completing Grate Set-upAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Securing Vent SectionsGas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Wall SwitchOptional Accessories Requirements Intellifire Ignition System WiringIntellifire Pilot Ignition IPI Wiring Diagram Standing Pilot Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Positioning the Logs Log Assembly LOGS-8OAKPage Grilles and Trim Glass AssemblyShutter Settings Screen MeshBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Check Appliance DraftFinal inspection by Lighting Appliance IPI IgnitionStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingSympton Possible Cause Corrective Action Intellifire Ignition Systemflame has been lit, flame Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramLog Set Assembly Service PartsPart number list on following Service Parts List StockedAt Depot 8000TV-OAK-IPI IPI Valve Assembly8000TV-OAK Standing Pilot Valve AssemblyLimited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information

8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI specifications

The Heat & Glo LifeStyle 8000TVLP-OAKIPI, 8000TV-OAK-IPI, and 8000TV-OAK are cutting-edge fireplace units that redefine the way we experience warmth and ambiance in our homes. Designed with a sleek and modern aesthetic, these gas fireplaces offer an ideal blend of style, comfort, and efficiency.

One of the standout features of the LifeStyle 8000 series is its expansive viewing area, which allows homeowners to enjoy an unobstructed view of the flickering flames. The large glass display not only enhances the visual appeal but also creates a welcoming atmosphere in any living space. The unit's clean lines and contemporary design ensure it complements a wide range of interior styles, from traditional to modern.

Efficiency is a hallmark of the LifeStyle 8000 series. Equipped with advanced heating technologies, these fireplaces provide effective warmth while utilizing fuel efficiently. The patented IntelliFire technology allows for easy ignition and reliable performance. Users can enjoy the convenience of controlled heat settings, ensuring that their space remains comfortable without excessive energy use.

Moreover, the LifeStyle series incorporates innovative safety features that provide peace of mind. With automatic shut-off options, homeowners can relax knowing that the fireplace will operate safely and efficiently. The removable mesh screen adds an extra layer of security while allowing families to enjoy the ambiance without worry.

Customization is another key aspect of the Heat & Glo LifeStyle 8000 series. Homeowners can choose from a variety of finishes, making it easy to match their fireplace to their home’s decor. Options for decorative media, such as glass and logs, allow users to create a look that suits their personal style.

Installation is made simple with the flexible venting options provided by these units. The designers have prioritized user-friendliness by ensuring that the units can fit into a variety of spaces, making them an excellent choice for both new builds and renovations.

In summary, the Heat & Glo LifeStyle 8000TVLP-OAKIPI, 8000TV-OAK-IPI, and 8000TV-OAK are impressive gas fireplaces that combine efficiency, safety, and aesthetic appeal. With their high-quality construction, advanced technology, and customizable features, they offer a luxurious and practical solution for any home seeking warmth and ambiance.