Heat & Glo LifeStyle GEM42 Intermittent Pilot Ignition, Valve Assembly, Service Parts, Serial #

Page 6
Intermittent Pilot Ignition

Service Parts

GEM42

 

 

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 7-02

(GN, PL) Vue éclatée des pièces

Ending Manufacturing Date: ______

Intermittent Pilot Ignition

9

7

 

8

18

Valve Assembly

 

 

 

 

 

19

 

 

 

 

17

 

10

 

 

 

 

11

 

 

 

12

5

 

 

16

 

 

 

13

 

4

2

15

 

 

 

 

14

 

6

 

3

1

 

 

 

 

 

 

 

 

 

ITEM /

 

 

 

 

 

 

 

 

DESCRIPTION

SERIAL #

PART NUMBER

PIÈCE

 

 

 

 

 

 

 

 

/ N° DE SÉRIE

/ N° DE PIÈCE

1

ON/OFF Rocker Switch

/

Interrupteur à bascule MARCHE/ARRÊT

 

060-521A

2

Valve NG /

Valve

GN

 

 

 

 

 

750-500

2

Valve LP /

Valve

PL

 

 

 

 

 

750-501

3

Flexible Gas Connector

/

 

Tuyau à gaz flexible

 

567-301A

4

Module / Module

 

 

 

 

 

593-592

5

Wire Assembly

/ Module de fil

 

593-590A

6

Rheostat Assembly /

Assemblée de Rhéostat

 

100-510A

7

Pilot Assembly NG / Module de veilleuse GN

 

370-510A

7

Pilot Assembly LP / Module de veilleuse PL

 

370-511A

8

Pilot Bracket / Parenthèse Pilote

 

370-165

9

Ground Strap

/

Courroie de Raison(Terre)

 

385-512

10

Valve Bracket

/

Parenthèse de Valve

 

370-155

11

Flex Ball Valve Assembly

/

Fléchir l'Assemblée de Soupape de Balle

 

302-320A

12

Control Panel

/

Tableau de commande avant

 

370-153

13

Flame Control Knob /

Flamber le Bouton de Contrôle

 

571-531

14

Rheostat Knob - Black

 

/ Bouton de Rhéostat - Noir

 

100-512

15

Shutter Rod

/

Tige d'Obturateur

 

370-350

16

Temp Sensor

/

 

Détecteur de température

 

107-531

17

Orifice Bracket

/

Parenthèse d'Orifice

 

370-120

18

Handle / Poignée

 

 

 

 

 

319-167

19

Burner Orifice NG (#29C)

/

Orifice de brûleur GN (#29C)

 

582-829

19

Burner Orifice LP (#48C)

/

Orifice de brûleur PL (#48C)

 

582-848

 

20 inch Wire Harness

/ Harnais de fil

 

107-559A

 

Pilot Support

/ Piloter le Soutien

 

385-120

6

Heat & Glo • GEM42 • 371-900 Rev. N • 2/05

Image 6
Contents GEM42 ModelInstallers Guide Underwriters Laboratories ListedREAD and UNDERSTAND all instructions carefully SAFETY AND WARNING INFORMATIONThis gas fireplace and vent assembly MUST be DO NOT USE this appliance if any part has beenService Parts Lists TABLE OF CONTENTSSafety and Warning Information Section 3 Installing the Fireplace5 Log set assembly Service PartsGEM42 NG, LP Exploded Parts DiagramService Parts List / Liste des pièces de rechange GEM42ACCESSORIES / ACCESSOIRES Valve Assembly Intermittent Pilot Ignition1Approvals and Codes Installation CodesHigh Altitude Installations Appliance CertificationIntroducing the Heat & Glo Gas Fireplaces Pre-install Preparation2Getting Started ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARDFigure 1. Diagram of the GEM42 Heat & Glo GEM42 371-900 Rev. N 2/05Step 1. Locating the Fireplace 3Installing the FireplaceConstructing the Fireplace Chase Fireplace Dimensions, Locations47-1/2” Step 2. Framing the FireplaceFigure 3. Framing Dimensions 47-3/4”NOTE PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT DVP90STTEMS OR COMPONENTS MAY BE USED Step 3. Installing the Vent SystemA. Vent System Approvals Identifying Vent ComponentsFlue Restrictor Instructions Pilot Shield AdjustmentSTRAIGHT UP VERTICAL VENTING V FT 40 MAX. 12.4 MELBOWS VENTING WITHTWO 2 90 o VENTING WITH ONE 1 90 ELBOWVENTING WITH THREE 3 90 ELBOWS V FTH FT H + H 1 FTVenting Out the Top Vent B. Installing Vent Components3. Install Support Brackets 1. Attach the First Vent Component to the Starting CollarsFigure 15. 10 x 12 Hole and Vent Pipe 4. Install FirestopsCut a 10-inch by 12-inch 254mm X 305mm hole through the wall Figure 16. Heat Shield, Interior & Exterior FirestopsWARNING THE TERMINATION CAP MUST BE C. Vent TerminationAttic Firestop POSITIONED SO THAT THE ARROW IS POINT- ING UPnot to be installed above a gas = AREA WHERE TERMINAL IS NOT PERMITTEDelectrical service meter/regulator assembly withinFigure 22. Minimum Height from Roof to Lowest Discharge Opening Step 4. Positioning, Leveling and Securing the FireplaceWARNING MAJOR U.S. BUILDING CODES SPECIFY MINIMUM CHIMNEY AND/OR Figure 23. Proper PositioningHeat-Zone Kit Step 5. Installing the Optional Heat-Out or Heat-Zone KitsHeat-Out Kit Step 6 The Gas Control SystemPressure Step 7. The Gas Supply LineStep 8. Gas Pressure Requirements Natural GasIntermittent Pilot Ignition IPI Wiring 3 Volt Transformer Step 9. Wiring the FireplaceFigure 26. Intermittent Pilot Ignition IPI Wiring Diagram Operation with Battery Back-upWARNING WHEN FINISHING THE FIREPLACE Step 10. FinishingFigure 27. Fan Wiring Diagram FINISH WALL MATERIALFigure 31. Facing Template Dimensions IMPORTANT INSTALLATION NOTEFacing Requirements Facing Thickness from 3/4” to 1-1/4”Figure 34. Glass Assembly Step 11. Installing Trim, Logs and Ember MaterialInstalling the Trim Glass Specifications GEM42 CERAMICStep 13. Lighting the Fireplace After the InstallationStep 12. Before Lighting the Fireplace Double-check for faulty componentsCleaning Flame Sensor Rod IPI Systems Frequency Annually Fireplace Maintenance4Maintaining and Servicing Your Fireplace Cleaning Glass Door