Cannon CANTFS-03-LP Gas control, Place log No.2 onto the 2 left back pins. Refer figure

Page 12

Advise the user in the operation of the heater.

Position the four individually numbered logs in the following order on the burner head as shown in figures 15 - 18. The male locating pins in the burner head must engage with corresponding holes in the indi- vidual logs.

a)Place log No.1 onto the 2 front left pins on the burner head, ensuring that the charring faces the front.

Refer figure 15.

15

b)Place log No.2 onto the 2 left back pins. Refer figure 16.

16

c)Place log No.3 on single right front pin, ensure fork locates over log

No. 2. Refer figure 17.

17

d)Place log No. 4 on single right

back pin, ensure left side of log rests on depression in No. 3 log.

Refer figure 18.

18

13.Refit the inner glass, but do not overtighten the screws.

14.Refit the front glass surround. En- sure that the glass surround is re- placed the correct side up. The rearward sloping frame must be at the top and the vertical edge must be at the bottom. Refer figure 19.

19

Gas control

15.Gas control layout is as indicated in figure 20

Operate the heater on HIGH and LOW burner and all fan speeds.

The flame should be stable, no lifting from the burner, and the logs should glow after approximately 15 minutes of operation on HIGH burner.

12

Image 12
Contents Cannon Contents Warranty DistributorSafety warnings What to do if you smell gasStandards User instructions Operating instructionsFor control lay-out refer to figure To turn burner on Flame characteristics CleaningHeater specifications Only125mm ø flue cowl Flue coverInstallation instructions InstallationOverall dimensions ClearancesLog installation Gas connectionPlace log No.2 onto the 2 left back pins. Refer figure Gas controlRefit the inner glass, but do not overtighten the screws Gas pressure point Page Installation tips Flue installation Standard flue kit Flue kitFlue installation Standard flue kit Flue installation Alternative double skin flue kit Alternative double skin flue installationAlternative flue kit Ceiling plate 75mm AGA approved flue cowlFlue installation Alternative double skin flue kit Service instructions Wiring diagram Data label For service to this appliance Trouble-shooting Connections No gas to burnerCanterbury

CANTFS-03-NG, CANTFS-03-LP specifications

The Cannon CANTFS-03-LP and CANTFS-03-NG are cutting-edge products designed to enhance the performance and efficiency of various applications in the industrial and commercial sectors. These high-performance devices bring together advanced technologies and innovative design, setting a new benchmark in their category.

One of the key features of both models is their robust construction, ensuring durability and reliability even in the most challenging environments. The CANTFS-03 series is engineered with premium materials that resist wear and corrosion, making them ideal for long-term use in demanding operational settings.

In terms of performance, the CANTFS-03-LP model excels in low-pressure applications, offering precision and control that can greatly improve process efficiency. Its advanced flow technology minimizes losses, ensuring optimal output without sacrificing safety. Meanwhile, the CANTFS-03-NG version is designed for high-pressure environments, providing superior strength and stability. This model utilizes enhanced sealing technology, which allows it to maintain integrity under even the most strenuous conditions.

Another distinguishing characteristic of the CANTFS-03 series is its user-friendly interface. The devices come equipped with intuitive controls that allow for easy adjustments and monitoring, making them accessible to operators with varying levels of expertise. This focus on usability contributes to reduced training times and increased operational efficiency.

Furthermore, both models incorporate state-of-the-art sensor technology that delivers real-time data on performance metrics. This feature not only streamlines operations but also enables predictive maintenance, significantly reducing downtime. The integration of smart technology allows for seamless connectivity with existing systems, facilitating enhanced data analytics and operational oversight.

Energy efficiency is also at the forefront of the design philosophy behind the CANTFS-03-LP and CANTFS-03-NG. These models are optimized to minimize energy consumption while maximizing output, making them environmentally friendly choices for businesses looking to reduce their carbon footprint.

In summary, the Cannon CANTFS-03-LP and CANTFS-03-NG are exceptional products that integrate durability, performance, and advanced technology. Their robust construction, user-friendly interfaces, real-time monitoring capabilities, and energy efficiency make them ideal solutions for businesses seeking to enhance their operational capabilities. Whether in low-pressure or high-pressure applications, these models stand out as reliable and efficient choices in today's competitive market.