Bryant manual Base Unit Dimensions, 581B036-072

Page 13

BASE UNIT DIMENSIONS

 

STANDARD

DURABLADE

 

 

CORNER

CORNER

CORNER

CORNER

BOTTOM POWER CHART, THESE HOLES REQUIRED FOR

 

ECONOMI$ER

USE WITH ACCESSORY PACKAGES — CRBTMPWR001A00,

UNIT

UNIT

ECONOMIZER

WEIGHT

WEIGHT

WEIGHT

WEIGHT

WEIGHT

3A00 (1/2, 3/4) OR CRBTMPWR002A00, 4A00 (1/2, 11/4)

581B

WEIGHT

WEIGHT

 

 

(A)

 

(B)

(C)

(D)

 

 

 

 

 

 

 

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

THREADED

WIRE

REQURED

036

530

240

34

15.4

47

21.3

127

57.6

122

55.3

138

62.6

143

64.9

CONDUIT SIZE

USE

HOLE SIZES (MAX.)

048

540

245

34

15.4

47

21.3

129

58.5

124

56.2

141

64.0

146

66.2

1/2

 

24 V

7/8[22.2]

060

560

254

34

15.4

47

21.3

134

60.8

129

58.5

146

66.2

151

68.5

3/4

 

Power*

11/8[28.4]

072

615

279

34

15.4

47

21.3

147

66.7

142

64.4

160

72.6

166

75.3

11/4

 

Power*

13/4[44.4]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(003) 1/2FPT

Gas

11/4[31.8]

 

 

CONNECTION SIZES

 

 

 

 

 

 

 

 

 

 

(004) 3/4FPT

Gas

15/8[41.3]

A

13/8Dia [35] Field Power Supply Hole

 

 

 

 

 

 

 

 

 

3

1

for power, depending on wire size.

B

2Dia [51] Power Supply Knockout

 

 

 

 

 

 

 

 

 

*Select either

/4

or 1 /4

 

C

13/4Dia [44] Charging Port Hole

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

D

7/8Dia [22] Field Control Wiring Hole

 

 

 

 

 

1.

Dimensions in [ ] are in millimeters.

 

 

 

 

 

E

3/4-14 NPT Condensate Drain

 

 

 

 

 

 

2.

 

Center of gravity.

 

 

 

 

 

 

F

1/2-14 NPT Gas Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

21/2Dia [64] Power Supply Knockout

 

 

 

 

 

3.

 

Direction of airflow.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. On vertical discharge units, ductwork to be attached to accessory roof curb only. For horizontal

 

 

 

 

 

 

 

 

 

 

 

 

discharge units, field-supplied flanges should be attached to horizontal discharge openings, and

 

 

 

 

 

 

 

 

 

 

 

 

all ductwork should be attached to the flanges.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Minimum clearance (local codes or jurisdiction may prevail):

 

 

 

 

 

 

 

 

 

 

 

 

 

a. Between unit, flue side and combustible surfaces, 48 inches.

 

 

 

 

 

 

 

 

 

 

 

 

 

b. Bottom of unit to combustible surfaces (when not using curb), 1 inch.

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of base rail to combustible surfaces (when not using curb) 0 inches.

 

 

 

 

 

 

 

 

 

 

 

 

c. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other. The side getting the

 

 

 

 

 

 

 

 

 

 

 

 

greater clearance is optional.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d. Overhead, 60 in. to assure proper condenser fan operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

e. Between units, control box side, 42 in. per NEC (National Electrical Code).

 

 

 

 

 

 

 

 

 

 

 

 

f. Between unit and ungrounded surfaces, control box side, 36 in. per NEC.

 

 

 

 

 

 

 

 

 

 

 

 

g. Between unit and block or concrete walls and other grounded surfaces, control box side,

 

 

 

 

 

 

 

 

 

 

 

 

42 in. per NEC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

h. Horizontal supply and return end, 0 inches.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. With the exception of the clearance for the condenser coil and combustion side as stated in

 

 

 

 

 

 

 

 

 

 

 

 

notes 5a, b and c, a removable fence or barricade requires no clearance.

 

 

 

 

 

 

 

 

 

 

 

7. Units may be installed on combustible floors made from wood or Class A, B, or C roof covering

 

 

 

 

 

 

 

 

 

 

 

 

material if set on base rail.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8. The vertical center of gravity is 1-6[457] up from the bottom of the base rail.

581B036-072

13

Image 13
Contents Easy Maintenance and Installation FEATURES/BENEFITSUnit 581B036-072 Unit 581B090-150FEATURES/BENEFITS Table of Contents Compressors and Safety Switches are Easily Accessible for ServiceabilityModel Number Nomenclature Indoor AIR Quality IAQHeating Capacities and Efficiencies ARI* CapacitiesLOW Ambient Controls Options and AccessoriesTime Guard II Control Liquid Propane Conversion KITOptions and Accessories Coil Guard Grille Hail Guard Accusensor II Enthalpy ControlBryant Commercial Programmable Thermostat Bryant Light Commercial ThermidistatHi-Static Physical Data060N††† Physical Data090N††† 120N†††090 102 120 150 Nominal Capacity tons LOSS-OF-CHARGE LOW-PRESSURE 581B036-072 Base Unit Dimensions581B090-150 Base Unit DimensionsAccessory Dimensions 581B036-072 Connector ALT Drain PKG. Accy GAS Accessory Dimensions 581B090-150Control CRRFCURB003A00II Select Unit Based on Required Cooling Capacity Selection Procedure With 581B048 ExampleDetermine NET Cooling Capacity Cooling Capacities Performance DataCooling Capacities Performance Data581B090 71/2 Tons 581B120 10 Tons Temp F Cooling CAPACITIES, Units with Perfect Humidity Option Cooling CAPACITIES, Units with Perfect Humidity Option 2250/0.10 3000/0.11 3750/0.14 Condenser 134.3 581B036 3 Tons Standard Motor Airflow FAN Performance Vertical Discharge Units581B036 3 Tons HIGH-STATIC Motor Airflow 581B048 4 Tons Standard Motor Airflow FAN Performance Vertical Discharge Units581B048 4 Tons HIGH-STATIC Motor Airflow 581B060 5 Tons Standard Motor THREE-PHASE Units Airflow 581B060 5 Tons Standard Motor SINGLE-PHASE Units Airflow581B060 5 Tons HIGH-STATIC Motor 581B072 6 Tons HIGH-STATIC Motor 581B072 6 Tons Standard Motor Airflow581B090 71/2 Tons HIGH-STATIC Motor Airflow 581B090 71/2 Tons Standard Motor581B102 81/2 Tons HIGH-STATIC Motor Airflow 581B120 10 Tons Standard and HIGH-STATIC Motor Airflow FAN Performance Horizontal Discharge Units FAN Performance Horizontal Discharge Units 581B060 5 Tons HIGH-STATIC Motor Airflow 581B060 5 Tons Standard Motor 3-PHASE Units Airflow1900 982 1084 1160 1223 Bhp Rpm 1800 885 942 10472000 1022 1121 1188 1264 2100 1063 1140 1196 1272581B090 71/2 Tons HIGH-STATIC Motor Airflow 2600 557 634 698 759 787 816 Bhp Rpm 2550 627 692 754 783 8122700 573 648 711 770 798 827 2800 588 662 723 782 809 8373200 519 680 741 818 3100 500 669 731 8083300 537 692 751 828 3400 561 704 761EVAPORATOR-FAN Motor Efficiency Outdoor Sound Power Total UnitFiop Perfect Humidity Dehumidification 581B FAN RPM AT Motor Pulley Setting with HIGH-STATIC Motor 581B FAN RPM AT Motor Pulley Setting with Standard MotorEVAPORATOR-FAN Motor Data Standard Motor Operating Watts EVAPORATOR-FAN Motor Data HIGH-STATIC MotorsEconoMi$er Outdoor-Air Leakage EconoMi$er Barometric Relief Damper CharacteristicsEconoMi$er Return-Air Pressure Drop Altitude Derating Factor Altitude Compensation581B036-150 OFM Electrical DataSupply FAN MotorRLA LRA FLA MCA MOCP† Electrical DataNominal Voltage Combustion Power Minimum Unit Compressor RLA LRA Application Data Maximum Operating OUTDOOR-AIR TemperatureApplications Application Data Perfect Humidity Dehumidification Option Pressure Enthalpy Curve Psychrometric Chart 581B072 Shown Vertical Discharge Typical Piping and WiringHorizontal Discharge Typical Wiring Schematic Typical Wiring Schematic OFC 581B090-150 Typical Wiring SchematicTran Operating Sequence for 581B036-072 Units ControlsOperating Sequence for 581B090-150 Units Operating Sequence for 581B036-150 Size Units ControlsPart 1 General Guide SpecificationsPart 2 Products Guide Specifications Light Commercial Thermidistat Page Specifications Subject to Change Without Notice
Related manuals
Manual 52 pages 16.87 Kb Manual 40 pages 47.12 Kb

581B specifications

The Bryant 581B is an innovative and highly efficient gas furnace that stands out in the HVAC market for its remarkable performance, reliability, and advanced features. Designed to provide optimal heating comfort, the Bryant 581B is perfect for homeowners seeking both quality and energy efficiency.

One of the main features of the Bryant 581B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating. With an AFUE rating of up to 80%, this gas furnace maximizes energy usage, ensuring that a significant portion of the fuel is converted into heat for your home. This efficiency not only translates into lower energy bills but also reduces the carbon footprint, making it an environmentally friendly choice.

The furnace is equipped with a multi-speed blower motor that enhances comfort by providing consistent airflow throughout the home. This technology adjusts to different heating demands, ensuring that every room reaches the desired temperature without the discomfort of hot or cold spots. The quiet operation of the blower motor also adds to the overall comfort, creating a peaceful home environment.

Another notable characteristic of the Bryant 581B is its durable construction. It features a robust heat exchanger built from high-quality materials, designed to withstand the rigors of daily use. The compact design of the furnace allows it to fit seamlessly into various spaces, making it an ideal choice for both new installations and replacement projects.

The Bryant 581B also comes with advanced safety features, including a self-diagnostic control board that monitors the system's performance. This feature allows for easy troubleshooting and maintenance, prolonging the life of the furnace. Additionally, the furnace is equipped with an induced draft blower that enhances venting efficiency and safety by ensuring that combustion gases are safely expelled from the home.

For homeowners looking for enhanced control, the Bryant 581B is compatible with a range of smart thermostats, providing the ability to monitor and adjust heating settings remotely. This integration with smart technology ensures that homeowners can maintain their desired comfort levels while maximizing efficiency.

In conclusion, the Bryant 581B gas furnace is a top-tier option that combines efficiency, durability, and modern technology. With its high AFUE rating, multi-speed blower, and advanced safety features, it promises to deliver unparalleled comfort and peace of mind for years to come. Whether for a new build or an upgrade, the Bryant 581B is an investment that pays off in both comfort and savings.