Bryant 581B manual Guide Specifications, Part 1 General, Part 2 Products

Page 60

GUIDE SPECIFICATIONS

PACKAGED ROOFTOP COOLING UNIT WITH GAS HEAT — CONSTANT VOLUME APPLICATION

HVAC GUIDE SPECIFICATIONS

SIZE RANGE: 3 TO 121/2 TONS, NOMINAL COOLING 72,000 TO 250,000 BTUH,

NOMINAL INPUT HEATING

BRYANT MODEL NUMBER: 581B

PART 1 — GENERAL

1.01 SYSTEM DESCRIPTION

Outdoor rooftop- or slab-mounted, electrically controlled heating and cooling utilizing a scroll compressor for cool- ing duty and gas combustion for heating duty. Unit shall discharge supply air vertically or horizontally as shown on contract drawings.

1.02QUALITY ASSURANCE

A.Unit shall be rated in accordance with ARI Standards 210/ 240 or 360 and 270.

B.Unit shall be designed to conform to ASHRAE 15, latest revision, and in accordance with UL 1995.

C.Unit shall be UL tested and certified in accordance with ANSI Z21.47 Standard and UL listed and certified under Canadian Standards as a total package for safety requirements.

D.Roof curb shall be designed to conform to NRCA Standards.

E.Insulation and adhesive shall meet NFPA 90A require- ments for flame spread and smoke generation.

C.Fans:

1.Indoor blower (evaporator fan) shall be of the belt-driven, double inlet, forward-curved centrifugal type. Belt drive shall include an adjustable-pitch motor pulley.

2.Indoor blower (evaporator fan) shall be made from steel with a corrosion-resistant finish and shall be dynamically balanced.

3.Bearings shall be of the sealed, permanently lubri- cated, ball-bearing type for longer life and lower maintenance.

4.Condenser fan shall be of the direct-driven propeller type and shall discharge air vertically upward.

5.Condenser fan shall have aluminum blades riveted to corrosion-resistant steel spiders and shall be dynam- ically balanced.

6.Condenser-fan motor shall be totally enclosed.

7.Induced draft blower shall be of the direct-driven, sin- gle inlet, forward curved, centrifugal type, shall be made from steel with a corrosion-resistant finish, and shall be dynamically balanced.

D.Compressor(s):

1.Fully hermetic scroll type, internally protected.

2.Factory rubber-shock mounted and internally spring mounted for vibration isolation.

3.On independent circuits (sizes 090-150).

E.Coils:

1.Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to enhanced copper tubes with all joints brazed.

F. Unit casing shall be capable of exceeding Federal Test Method Standard No. 141 (Method 6061) 500-hour Salt Spray Test.

G.Each 581B unit is subjected to completely automated run testing on the assembly line. Each unit contains a factory- supplied printout indicating tested pressures, amperages, data, and inspectors; providing certification of the unit status at the time of manufacture.

1.03DELIVERY, STORAGE, AND HANDLING

Unit(s) shall be stored and handled per manufacturer’s recommendations.

PART 2 — PRODUCTS

2.01EQUIPMENT (STANDARD)

A.General:

Factory-assembled, single-piece heating and cooling unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, refrigerant charge (R-22), and special features required prior to field start-up.

B.Unit Cabinet:

1.Unit cabinet shall be constructed of galvanized steel, bonderized and coated with a baked enamel finish on all externally exposed surfaces, and have primer- coated interior surfaces on all panels.

2.Tube sheet openings shall be belled to prevent tube wear.

3.Evaporator coil shall be of the face-split design.

F.Heating Section:

1.Induced draft combustion type with energy saving direct spark ignition system, redundant main gas valve.

2.The heat exchanger shall be of the tubular section type constructed of a minimum of 20 gage steel coated with a nominal 1.2 mil aluminum-silicone alloy for corrosion resistance.

3.Burners shall be of the in-shot type constructed of aluminum coated steel.

4.All gas piping shall enter the unit cabinet at a single location.

5.The Integrated Gas Control (IGC) board shall provide timed control of evaporator fan functioning and burner ignition. An LED (light-emitting diode) shall provide diagnostic information. The LED shall be vis- ible without removing the control box access panel.

6.IGC board contains anti-cycle protection for gas heat operation (after 4 continuous cycles on high temper- ature limit switch and one cycle on the flame rollout switch).

2.Evaporator-fan cabinet interior shall be insulated with

a minimum 1/2-in. thick flexible fiberglass insulation coated on the air side. Aluminum foil-faced fiberglass insulation shall be used in the heating compartment.

3.Cabinet panels shall be easily removable for servicing.

4.Holes shall be provided in the base rails for rigging shackles to facilitate overhead rigging, and forklift slots shall be provided to facilitate maneuvering.

5.Unit shall have a factory-installed, sloped conden- sate drain pan made of a non-corrosive material, pro-

viding a minimum 3/4-in. connection with both vertical and horizontal drains and shall comply with ASHRAE 62.

6.Unit shall have factory-installed filter access panel to provide filter access with tool-less removal.

7.Unit shall have standard thru-the-bottom power con- nection capability.

G.Refrigerant Components:

Refrigerant circuit components shall include:

1.Fixed-orifice type feed system.

2.Refrigerant strainer.

3.Service gage connections on suction, discharge, and liquid lines.

4.Filter drier.

5.Ability to route gage hoses through unit top cover (unit sizes 036-072 only).

H.Filter Section:

1.Standard filter section shall consist of factory- installed low-velocity, throwaway 2-in. thick fiberglass filters of commercially available sizes.

2.Filter face velocity shall not exceed 300 fpm at nomi- nal airflows.

3.Filter section shall use only one size filter.

4.Filters shall be accessible through an access panel with ‘‘no-tool’’ removal.

60

Image 60
Contents FEATURES/BENEFITS Easy Maintenance and InstallationUnit 581B036-072 Unit 581B090-150FEATURES/BENEFITS Table of Contents Serviceability Compressors and Safety Switches are Easily Accessible forModel Number Nomenclature Indoor AIR Quality IAQARI* Capacities Heating Capacities and EfficienciesOptions and Accessories LOW Ambient ControlsTime Guard II Control Liquid Propane Conversion KITOptions and Accessories Hail Guard Accusensor II Enthalpy Control Coil Guard GrilleBryant Commercial Programmable Thermostat Bryant Light Commercial ThermidistatPhysical Data Hi-StaticPhysical Data 060N†††090N††† 120N†††090 102 120 150 Nominal Capacity tons LOSS-OF-CHARGE LOW-PRESSURE Base Unit Dimensions 581B036-072Base Unit Dimensions 581B090-150Accessory Dimensions 581B036-072 Accessory Dimensions 581B090-150 Connector ALT Drain PKG. Accy GASControl CRRFCURB003A00Selection Procedure With 581B048 Example II Select Unit Based on Required Cooling CapacityDetermine NET Cooling Capacity Performance Data Cooling CapacitiesPerformance Data Cooling Capacities581B090 71/2 Tons 581B120 10 Tons Temp F Cooling CAPACITIES, Units with Perfect Humidity Option Cooling CAPACITIES, Units with Perfect Humidity Option 2250/0.10 3000/0.11 3750/0.14 Condenser 134.3 FAN Performance Vertical Discharge Units 581B036 3 Tons Standard Motor Airflow581B036 3 Tons HIGH-STATIC Motor Airflow FAN Performance Vertical Discharge Units 581B048 4 Tons Standard Motor Airflow581B048 4 Tons HIGH-STATIC Motor Airflow 581B060 5 Tons Standard Motor SINGLE-PHASE Units Airflow 581B060 5 Tons Standard Motor THREE-PHASE Units Airflow581B060 5 Tons HIGH-STATIC Motor 581B072 6 Tons Standard Motor Airflow 581B072 6 Tons HIGH-STATIC Motor581B090 71/2 Tons Standard Motor 581B090 71/2 Tons HIGH-STATIC Motor Airflow581B102 81/2 Tons HIGH-STATIC Motor Airflow 581B120 10 Tons Standard and HIGH-STATIC Motor Airflow FAN Performance Horizontal Discharge Units FAN Performance Horizontal Discharge Units 581B060 5 Tons Standard Motor 3-PHASE Units Airflow 581B060 5 Tons HIGH-STATIC Motor AirflowBhp Rpm 1800 885 942 1047 1900 982 1084 1160 12232000 1022 1121 1188 1264 2100 1063 1140 1196 1272581B090 71/2 Tons HIGH-STATIC Motor Airflow Bhp Rpm 2550 627 692 754 783 812 2600 557 634 698 759 787 8162700 573 648 711 770 798 827 2800 588 662 723 782 809 8373100 500 669 731 808 3200 519 680 741 8183300 537 692 751 828 3400 561 704 761Outdoor Sound Power Total Unit EVAPORATOR-FAN Motor EfficiencyFiop Perfect Humidity Dehumidification 581B FAN RPM AT Motor Pulley Setting with Standard Motor 581B FAN RPM AT Motor Pulley Setting with HIGH-STATIC MotorEVAPORATOR-FAN Motor Data Standard Motor EVAPORATOR-FAN Motor Data HIGH-STATIC Motors Operating WattsEconoMi$er Barometric Relief Damper Characteristics EconoMi$er Outdoor-Air LeakageEconoMi$er Return-Air Pressure Drop Altitude Compensation Altitude Derating Factor581B036-150 Electrical Data OFMSupply FAN MotorElectrical Data RLA LRA FLA MCA MOCP†Nominal Voltage Combustion Power Minimum Unit Compressor RLA LRA Maximum Operating OUTDOOR-AIR Temperature Application DataApplications Application Data Perfect Humidity Dehumidification Option Pressure Enthalpy Curve Psychrometric Chart 581B072 Shown Typical Piping and Wiring Vertical DischargeHorizontal Discharge Typical Wiring Schematic Typical Wiring Schematic 581B090-150 Typical Wiring Schematic OFCTran Controls Operating Sequence for 581B036-072 UnitsOperating Sequence for 581B090-150 Units Controls Operating Sequence for 581B036-150 Size UnitsGuide Specifications Part 1 GeneralPart 2 Products Guide Specifications Light Commercial Thermidistat Page Specifications Subject to Change Without Notice
Related manuals
Manual 52 pages 16.87 Kb Manual 40 pages 47.12 Kb

581B specifications

The Bryant 581B is an innovative and highly efficient gas furnace that stands out in the HVAC market for its remarkable performance, reliability, and advanced features. Designed to provide optimal heating comfort, the Bryant 581B is perfect for homeowners seeking both quality and energy efficiency.

One of the main features of the Bryant 581B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating. With an AFUE rating of up to 80%, this gas furnace maximizes energy usage, ensuring that a significant portion of the fuel is converted into heat for your home. This efficiency not only translates into lower energy bills but also reduces the carbon footprint, making it an environmentally friendly choice.

The furnace is equipped with a multi-speed blower motor that enhances comfort by providing consistent airflow throughout the home. This technology adjusts to different heating demands, ensuring that every room reaches the desired temperature without the discomfort of hot or cold spots. The quiet operation of the blower motor also adds to the overall comfort, creating a peaceful home environment.

Another notable characteristic of the Bryant 581B is its durable construction. It features a robust heat exchanger built from high-quality materials, designed to withstand the rigors of daily use. The compact design of the furnace allows it to fit seamlessly into various spaces, making it an ideal choice for both new installations and replacement projects.

The Bryant 581B also comes with advanced safety features, including a self-diagnostic control board that monitors the system's performance. This feature allows for easy troubleshooting and maintenance, prolonging the life of the furnace. Additionally, the furnace is equipped with an induced draft blower that enhances venting efficiency and safety by ensuring that combustion gases are safely expelled from the home.

For homeowners looking for enhanced control, the Bryant 581B is compatible with a range of smart thermostats, providing the ability to monitor and adjust heating settings remotely. This integration with smart technology ensures that homeowners can maintain their desired comfort levels while maximizing efficiency.

In conclusion, the Bryant 581B gas furnace is a top-tier option that combines efficiency, durability, and modern technology. With its high AFUE rating, multi-speed blower, and advanced safety features, it promises to deliver unparalleled comfort and peace of mind for years to come. Whether for a new build or an upgrade, the Bryant 581B is an investment that pays off in both comfort and savings.