Bryant 581B manual Rla Lra

Page 48

ELECTRICAL DATA (cont)

581B090-120 HIGH-STATIC MOTOR (Units Without Electrical Convenience Outlet)

 

 

NOMINAL

VOLTAGE

COMPRESSOR

 

 

COMBUSTION

POWER

MINIMUM UNIT

UNIT

OFM

IFM

DISCONNECT

VOLTAGE

RANGE

 

(each)

FAN MOTOR

SUPPLY

581B

 

 

 

 

SIZE*

(V-Ph-Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

Max

RLA

 

LRA

FLA

FLA

RLA

MCA

MOCP

FLA

 

LRA

 

 

 

 

 

 

 

208/230-3-60

187

254

12.4

 

88.0

1.4

10.6

0.6

41.3

45†

44

 

267

090

 

460-3-60

414

508

6.4

 

44.0

0.7

4.8

0.3

20.6

25†

22

 

134

 

 

575-3-60

518

632

4.8

 

34.0

0.7

4.8

0.3

15.8

20†

17

 

95

 

 

208/230-3-60

187

254

15.0

 

99.0

1.4

10.6

0.6

47.2

60†

50

 

264

102

 

460-3-60

414

508

8.2

 

49.5

0.7

4.8

0.3

24.7

30†

26

 

132

 

 

575-3-60

518

632

5.8

 

40.0

0.7

4.8

0.3

18.0

20†

19

 

107

 

 

208/230-3-60

187

254

17.3

 

125.0

1.4

15.0

0.6

56.7

70

61

 

360

120

 

460-3-60

414

508

9.0

 

62.0

0.7

7.4

0.3

29.1

35†

29

 

181

 

 

575-3-60

518

632

7.1

 

50.0

0.7

7.4

0.3

23.0

25†

23

 

136

581B090-120 HIGH-STATIC MOTOR (Units With Electrical Convenience Outlet)

 

 

NOMINAL

VOLTAGE

COMPRESSOR

OFM

IFM

COMBUSTION

POWER

MINIMUM UNIT

UNIT

DISCONNECT

VOLTAGE

RANGE

 

(each)

FAN MOTOR

SUPPLY

581B

 

 

 

 

SIZE*

(V-Ph-Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

Max

RLA

 

LRA

FLA

FLA

RLA

MCA

MOCP

FLA

 

LRA

 

 

 

 

 

 

 

208/230-3-60

187

254

12.4

 

88.0

1.4

10.6

0.6

47.3

50†

49

 

267

090

 

460-3-60

414

508

6.4

 

44.0

0.7

4.8

0.3

23.3

25†

24

 

134

 

 

575-3-60

518

632

4.8

 

34.0

0.7

4.8

0.3

18.5

20†

19

 

95

 

 

208/230-3-60

187

254

15.0

 

99.0

1.4

10.6

0.6

53.2

60†

55

 

264

102

 

460-3-60

414

508

8.2

 

49.5

0.7

4.8

0.3

27.4

30†

28

 

132

 

 

575-3-60

518

632

5.8

 

40.0

0.7

4.8

0.3

20.7

25†

21

 

107

 

 

208/230-3-60

187

254

17.3

 

125.0

1.4

15.0

0.6

62.7

70

66

 

360

120

 

460-3-60

414

508

9.0

 

62.0

0.7

7.4

0.3

31.8

35†

32

 

181

 

 

575-3-60

518

632

7.1

 

50.0

0.7

7.4

0.3

25.7

30†

25

 

147

LEGEND

FLA — Full Load Amps

HACR — Heating, Air Conditioning and Refrigeration

IFM — Indoor (Evaporator) Fan Motor

LRA — Locked Rotor Amps

MCA — Minimum Circuit Amps

MOCP— Maximum Overcurrent Protection

NEC — National Electrical Code

OFM — Outdoor (Condenser) Fan Motor

RLA — Rated Load Amps

UL — Underwriters’ Laboratories

*Used to determine minimum disconnect per NEC.

†Fuse or HACR circuit breaker per NEC.

NOTES:

1. In compliance with NEC requirements for multimotor and combina-

tion load equipment (refer to NEC Articles 430 and 440), the overcur-

rent protective device for the unit shall be fuse or HACR breaker. The

Example: Supply voltage is 460-3-60.

AB = 452 v

BC = 464 v

AC = 455 v

452 + 464 + 455

Average Voltage =

3

1371

=

3

= 457

Determine maximum deviation from average voltage. (AB) 457 – 452 = 5 v

(BC) 464 – 457 = 7 v (AC) 457 – 455 = 2 v

Maximum deviation is 7 v.

Determine percent of voltage imbalance.

UL, Canada approved units may be fuse or circuit breaker.

2. Unbalanced 3-Phase Supply Voltage

% Voltage Imbalance = 100 x

7

Never operate a motor where a phase imbalance in supply voltage is

greater than 2%. Use the following formula to determine the percent

of voltage imbalance.

% Voltage imbalance

= 100 x

max voltage deviation from average voltage

average voltage

 

457

= 1.53%

This amount of phase imbalance is satisfactory as it is below the maxi- mum allowable 2%.

IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

48

Image 48
Contents FEATURES/BENEFITS Easy Maintenance and InstallationUnit 581B036-072 Unit 581B090-150FEATURES/BENEFITS Table of Contents Serviceability Compressors and Safety Switches are Easily Accessible forModel Number Nomenclature Indoor AIR Quality IAQARI* Capacities Heating Capacities and EfficienciesOptions and Accessories LOW Ambient ControlsTime Guard II Control Liquid Propane Conversion KITOptions and Accessories Hail Guard Accusensor II Enthalpy Control Coil Guard GrilleBryant Commercial Programmable Thermostat Bryant Light Commercial ThermidistatPhysical Data Hi-StaticPhysical Data 060N†††090N††† 120N†††090 102 120 150 Nominal Capacity tons LOSS-OF-CHARGE LOW-PRESSURE Base Unit Dimensions 581B036-072Base Unit Dimensions 581B090-150Accessory Dimensions 581B036-072 Accessory Dimensions 581B090-150 Connector ALT Drain PKG. Accy GASControl CRRFCURB003A00Selection Procedure With 581B048 Example II Select Unit Based on Required Cooling CapacityDetermine NET Cooling Capacity Performance Data Cooling CapacitiesPerformance Data Cooling Capacities581B090 71/2 Tons 581B120 10 Tons Temp F Cooling CAPACITIES, Units with Perfect Humidity Option Cooling CAPACITIES, Units with Perfect Humidity Option 2250/0.10 3000/0.11 3750/0.14 Condenser 134.3 FAN Performance Vertical Discharge Units 581B036 3 Tons Standard Motor Airflow581B036 3 Tons HIGH-STATIC Motor Airflow FAN Performance Vertical Discharge Units 581B048 4 Tons Standard Motor Airflow581B048 4 Tons HIGH-STATIC Motor Airflow 581B060 5 Tons Standard Motor SINGLE-PHASE Units Airflow 581B060 5 Tons Standard Motor THREE-PHASE Units Airflow581B060 5 Tons HIGH-STATIC Motor 581B072 6 Tons Standard Motor Airflow 581B072 6 Tons HIGH-STATIC Motor581B090 71/2 Tons Standard Motor 581B090 71/2 Tons HIGH-STATIC Motor Airflow581B102 81/2 Tons HIGH-STATIC Motor Airflow 581B120 10 Tons Standard and HIGH-STATIC Motor Airflow FAN Performance Horizontal Discharge Units FAN Performance Horizontal Discharge Units 581B060 5 Tons Standard Motor 3-PHASE Units Airflow 581B060 5 Tons HIGH-STATIC Motor AirflowBhp Rpm 1800 885 942 1047 1900 982 1084 1160 12232000 1022 1121 1188 1264 2100 1063 1140 1196 1272581B090 71/2 Tons HIGH-STATIC Motor Airflow Bhp Rpm 2550 627 692 754 783 812 2600 557 634 698 759 787 8162700 573 648 711 770 798 827 2800 588 662 723 782 809 8373100 500 669 731 808 3200 519 680 741 8183300 537 692 751 828 3400 561 704 761Outdoor Sound Power Total Unit EVAPORATOR-FAN Motor EfficiencyFiop Perfect Humidity Dehumidification 581B FAN RPM AT Motor Pulley Setting with Standard Motor 581B FAN RPM AT Motor Pulley Setting with HIGH-STATIC MotorEVAPORATOR-FAN Motor Data Standard Motor EVAPORATOR-FAN Motor Data HIGH-STATIC Motors Operating WattsEconoMi$er Barometric Relief Damper Characteristics EconoMi$er Outdoor-Air LeakageEconoMi$er Return-Air Pressure Drop Altitude Compensation Altitude Derating Factor581B036-150 Electrical Data OFMSupply FAN MotorElectrical Data RLA LRA FLA MCA MOCP†Nominal Voltage Combustion Power Minimum Unit Compressor RLA LRA Maximum Operating OUTDOOR-AIR Temperature Application DataApplications Application Data Perfect Humidity Dehumidification Option Pressure Enthalpy Curve Psychrometric Chart 581B072 Shown Typical Piping and Wiring Vertical DischargeHorizontal Discharge Typical Wiring Schematic Typical Wiring Schematic 581B090-150 Typical Wiring Schematic OFCTran Controls Operating Sequence for 581B036-072 UnitsOperating Sequence for 581B090-150 Units Controls Operating Sequence for 581B036-150 Size UnitsGuide Specifications Part 1 GeneralPart 2 Products Guide Specifications Light Commercial Thermidistat Page Specifications Subject to Change Without Notice
Related manuals
Manual 52 pages 16.87 Kb Manual 40 pages 47.12 Kb

581B specifications

The Bryant 581B is an innovative and highly efficient gas furnace that stands out in the HVAC market for its remarkable performance, reliability, and advanced features. Designed to provide optimal heating comfort, the Bryant 581B is perfect for homeowners seeking both quality and energy efficiency.

One of the main features of the Bryant 581B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating. With an AFUE rating of up to 80%, this gas furnace maximizes energy usage, ensuring that a significant portion of the fuel is converted into heat for your home. This efficiency not only translates into lower energy bills but also reduces the carbon footprint, making it an environmentally friendly choice.

The furnace is equipped with a multi-speed blower motor that enhances comfort by providing consistent airflow throughout the home. This technology adjusts to different heating demands, ensuring that every room reaches the desired temperature without the discomfort of hot or cold spots. The quiet operation of the blower motor also adds to the overall comfort, creating a peaceful home environment.

Another notable characteristic of the Bryant 581B is its durable construction. It features a robust heat exchanger built from high-quality materials, designed to withstand the rigors of daily use. The compact design of the furnace allows it to fit seamlessly into various spaces, making it an ideal choice for both new installations and replacement projects.

The Bryant 581B also comes with advanced safety features, including a self-diagnostic control board that monitors the system's performance. This feature allows for easy troubleshooting and maintenance, prolonging the life of the furnace. Additionally, the furnace is equipped with an induced draft blower that enhances venting efficiency and safety by ensuring that combustion gases are safely expelled from the home.

For homeowners looking for enhanced control, the Bryant 581B is compatible with a range of smart thermostats, providing the ability to monitor and adjust heating settings remotely. This integration with smart technology ensures that homeowners can maintain their desired comfort levels while maximizing efficiency.

In conclusion, the Bryant 581B gas furnace is a top-tier option that combines efficiency, durability, and modern technology. With its high AFUE rating, multi-speed blower, and advanced safety features, it promises to deliver unparalleled comfort and peace of mind for years to come. Whether for a new build or an upgrade, the Bryant 581B is an investment that pays off in both comfort and savings.