Carrier HUMCCLFP1025-A specifications → Humidifiers, Safety Considerations

Page 1

Humidifiers and

Humidistat

Visit www.carrier.com

Installation, Start-Up, and Operating Instructions

MODEL HUMCCLFP1025-A--

FAN-POWERED

HUMIDIFIER

 

MODEL HUMCCSFP1016-A--

MODEL HUMCCLBP2018-A--

FAN-POWERED

HUMIDIFIER

BYPASS HUMIDIFIER

 

MODEL HUMCCWTR2019-A--

MODEL HUMCCSBP2017-A--

WATER-SAVER

 

BYPASS HUMIDIFIER

 

A98362

Humidifiers

NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation.

This symbol indicates a change since the last issue.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, distributor, or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and National Electrical Code (NEC) for special require- ments.

Recognize safety information. This is the safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.

Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. Turn off accessory heater power if applicable. Elec- trical shock can cause personal injury or death.

Unit must not be installed where freezing temperatures could occur. Do not install unit on the furnace or fan coil jacket. Do not install unit where ends of cooling coil could restrict airflow to the humidifier. Condensation damage could occur if home has closed-off, unheated rooms.

INSTALLATION OF HUMCCLBP2018-A--

BYPASS HUMIDIFIER

Carrier's HUMCCLBP2018-A-- bypass humidifier can be in- stalled on either the supply or return plenum of a forced-air system. This unit requires an external bypass duct between the supply- and return-air ductwork.

It is recommended to install the humidifier where it can be easily serviced. If this humidifier is installed with a central cooling system the bypass duct must have a shutoff damper to close during the cooling season. Always install humidifier downstream of an electronic air cleaner.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

4

PC 101

Catalog No. 03HU-MC1

Printed in U.S.A.

Form HUM-1SI

Pg 1

7-98

Replaces: 49-4SI

Tab

7a

9a

 

 

 

 

 

 

 

Image 1
Contents Installation of HUMCCLBP2018-A Bypass Humidifier Safety Considerations→ Humidifiers → ÐMounting the Humidifier → ÐInstallation of HUMCCLBP2018-A-- Bypass-Type Humidifier→ ÐInstallation of HUMCCLFP1025-A-- Fan-Type Humidifier → ÐInstallation of Humidistat on Bypass-Type HumidifierInstallation of HUMCCLFP1025-A FAN Powered Humidifier Installation of HUMCCSFP1016-A FAN Powered Humidifier → ÐInstall Drain LineÐMount the Humidifier Select Location See FigÐMount Solenoid Valve Installation of HUMCCSBP2017-A Bypass Humidifier→ ÐMounting Solenoid Valve on HUMCCSBP2017-A-- Humidifier → ÐInstallation of HUMCCSBP2017-A Bypass-Type HumidifierÐMount Humidifier Installation of HUMCCWTR2019-A Bypass Water Saver Humidifier → ÐInstallation of HUMCCWTR2019-A-- Water Saver Humidifier → ÐValve and Media Assembly for HUMCCWTR2019-AÐWall Mounting Low Voltage Installation of HumidistatÐAdjustment ÐWiringÐDuct Mounting Low Voltage ÐOperation Recommended Humidistat SettingÐCheckout

HUMCCLFP1025-A specifications

The Carrier HUMCCLFP1025-A is a high-performance air handling unit designed for modern commercial and industrial applications. This model stands out due to its advanced engineering, energy efficiency, and superior air quality management. It addresses the growing demand for effective climate control solutions while ensuring compliance with environmental regulations.

One of the primary features of the HUMCCLFP1025-A is its innovative design, which promotes optimal airflow and temperature regulation. The unit is equipped with a multi-speed fan system that allows for precise adjustments based on the requirements of the space. This flexibility ensures reduced energy consumption while maintaining comfort levels. Additionally, its advanced EC motor technology enhances operational efficiency, leading to significant energy savings over time.

The HUMCCLFP1025-A also incorporates a robust filtering system that captures airborne pollutants, allergens, and particulate matter. The unit utilizes high-efficiency filters, which improve the overall air quality while extending the life of the equipment. The integration of a demand-controlled ventilation system further maximizes efficiency by adjusting the airflow based on occupancy levels, ensuring that only the necessary amount of conditioned air is supplied.

Another noteworthy characteristic of this model is its modular construction. The HUMCCLFP1025-A can be easily customized to meet the specific requirements of various applications. This adaptability allows for easy installation and maintenance, making it a practical choice for building managers and HVAC contractors alike. The unit is designed for quiet operation, minimizing noise disruption in sensitive environments such as offices and healthcare facilities.

Furthermore, the Carrier HUMCCLFP1025-A features advanced connectivity options, including compatibility with Building Management Systems (BMS). This allows for remote monitoring and control, enabling operators to optimize performance and troubleshoot issues in real time. The integration of smart technologies enhances the unit's capabilities, making it a forward-thinking solution in HVAC systems.

In conclusion, the Carrier HUMCCLFP1025-A is a versatile and efficient air handling unit that combines sophisticated design, advanced technology, and superior air quality management. Its range of features, including energy efficiency, customizable configurations, and smart connectivity, make it an ideal choice for various commercial and industrial environments. As the demand for sustainable and effective climate control solutions continues to grow, the HUMCCLFP1025-A stands out as a reliable option that meets the needs of today and the future.