Carrier HUMCCLFP1025-A specifications ÐDuct Mounting Low Voltage, ÐWiring, ÐAdjustment

Page 11

CASING

CONTROL

TAB

A97103

Fig. 19ÐSwitch Assembly Removal

5.Mount case horizontally over wires directly to wall using 2 long screws provided.

6.Replace faceplate and knob.

Step 2ÐDuct Mounting (Low Voltage)

1.Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in. upstream of elbow so element will be affected by normal airflow. (See Fig. 20.)

2.Remove protective backing from template furnished with each control and apply self-adhesive side on return air duct at selected location. Following instructions on template and in Fig. 21, drill 2 mounting holes and six 1/4-in. diameter sensing holes in duct. Sensing holes allow return air to reach nylon sensing element and operate humidistat.

NOTE: If desired, cut square hole in duct as indicated on template as an alternative to holes.

3.Remove protective backing from foam gasket provided with control and apply to template.

4.Run low-voltage wire from humidifier to template. Lay wire over 1 side of foam gasket. Wire can enter humidistat case from any direction.

IMPORTANT: Do not position wire directly under standoff pro- jections at back of case. If wire is under these projections, case will not seat tightly against gasket causing air leakage and possible improper operation.

5.Remove knob, faceplate, and switch assembly from case by following steps listed below.

a.Remove knob by pulling away from casing. (See Fig. 18.)

b.Lift off faceplate, starting at right side. Left end of faceplate protrudes under lip on casing. (See Fig. 18.)

c.Remove switch by removing 2 screws in back of casing. Pressing tab on case. Lift out control. (See Fig. 19.)

6.Make connections to screw terminals on switch assembly. Re-install switch into casing Ð secure with 2 short screws.

7.While holding wire in place. Mount humidistat case horizon- tally on duct using 2 mounting screws provided. Tighten firmly so that gasket seals space around wires and between case and duct. (See Fig. 21.)

8.Replace faceplate and knob.

Step 3ÐWiring

All wiring must comply with local codes and ordinances.

Step 4ÐAdjustment

Recommended humidistat setting should only be used as a guide. After adjustment of setting, allow at least 5 hr for equilibrium to be reached. Condensation on single pane windows or woodwork indicates excessive moisture. Condensation must not be allowed to continue for extended periods of time, or moisture damage can result. Lower humidistat setting in small steps until condensation disappears. However, if air is too dry, raise the setting.

ALTERNATE LOCATIONS

RETURN AIR

RETURN AIR

5 IN. MIN.

BEST LOCATION

15 IN. MIN.

RETURN AIR DUCT

A97104

Fig. 20ÐAlternate Location Duct Mount Installation

11

Image 11
Contents → Humidifiers Safety ConsiderationsInstallation of HUMCCLBP2018-A Bypass Humidifier → ÐMounting the Humidifier → ÐInstallation of HUMCCLBP2018-A-- Bypass-Type HumidifierInstallation of HUMCCLFP1025-A FAN Powered Humidifier → ÐInstallation of Humidistat on Bypass-Type Humidifier→ ÐInstallation of HUMCCLFP1025-A-- Fan-Type Humidifier Installation of HUMCCSFP1016-A FAN Powered Humidifier → ÐInstall Drain LineÐMount the Humidifier Select Location See FigÐMount Solenoid Valve Installation of HUMCCSBP2017-A Bypass HumidifierÐMount Humidifier → ÐInstallation of HUMCCSBP2017-A Bypass-Type Humidifier→ ÐMounting Solenoid Valve on HUMCCSBP2017-A-- Humidifier Installation of HUMCCWTR2019-A Bypass Water Saver Humidifier → ÐInstallation of HUMCCWTR2019-A-- Water Saver Humidifier → ÐValve and Media Assembly for HUMCCWTR2019-AÐWall Mounting Low Voltage Installation of HumidistatÐDuct Mounting Low Voltage ÐWiringÐAdjustment ÐCheckout Recommended Humidistat SettingÐOperation

HUMCCLFP1025-A specifications

The Carrier HUMCCLFP1025-A is a high-performance air handling unit designed for modern commercial and industrial applications. This model stands out due to its advanced engineering, energy efficiency, and superior air quality management. It addresses the growing demand for effective climate control solutions while ensuring compliance with environmental regulations.

One of the primary features of the HUMCCLFP1025-A is its innovative design, which promotes optimal airflow and temperature regulation. The unit is equipped with a multi-speed fan system that allows for precise adjustments based on the requirements of the space. This flexibility ensures reduced energy consumption while maintaining comfort levels. Additionally, its advanced EC motor technology enhances operational efficiency, leading to significant energy savings over time.

The HUMCCLFP1025-A also incorporates a robust filtering system that captures airborne pollutants, allergens, and particulate matter. The unit utilizes high-efficiency filters, which improve the overall air quality while extending the life of the equipment. The integration of a demand-controlled ventilation system further maximizes efficiency by adjusting the airflow based on occupancy levels, ensuring that only the necessary amount of conditioned air is supplied.

Another noteworthy characteristic of this model is its modular construction. The HUMCCLFP1025-A can be easily customized to meet the specific requirements of various applications. This adaptability allows for easy installation and maintenance, making it a practical choice for building managers and HVAC contractors alike. The unit is designed for quiet operation, minimizing noise disruption in sensitive environments such as offices and healthcare facilities.

Furthermore, the Carrier HUMCCLFP1025-A features advanced connectivity options, including compatibility with Building Management Systems (BMS). This allows for remote monitoring and control, enabling operators to optimize performance and troubleshoot issues in real time. The integration of smart technologies enhances the unit's capabilities, making it a forward-thinking solution in HVAC systems.

In conclusion, the Carrier HUMCCLFP1025-A is a versatile and efficient air handling unit that combines sophisticated design, advanced technology, and superior air quality management. Its range of features, including energy efficiency, customizable configurations, and smart connectivity, make it an ideal choice for various commercial and industrial environments. As the demand for sustainable and effective climate control solutions continues to grow, the HUMCCLFP1025-A stands out as a reliable option that meets the needs of today and the future.