Honeywell IPGSM-DP manual Wiring Diagram, + Battery

Page 15

Wiring Diagram

The wiring diagram below is depicted for point-to-point electrical connection checks used for troubleshooting or component replacement. It is not intended to show the physical routing of wires. When replacing a wire or component, ensure the wire is routed in the same manner as the original factory wire.

 

TRANSFORMER

WALL OUTLET

 

BOX (K14358)

ANTENNA

(N8167)

 

CABINET

DOOR

(Buzzer)

WHT (LO BATT)

LED Display

Buzzer RADIO TROUBLE

OPTIONAL CABINET TAMPER SWITCH

PowerBoost1

Tip 2 Ring 2 ZN- EOL EOL

ZN+ PWR GND Tip 1 Ring 1

YEL

in GRN

RED

Out

V In NBLKD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIO

 

BLK

LOW BATT

LOW BATT

TROUBLE

ECP

Data Data 12 G

Telco 1

RED

GREEN

Telco 2

Dialer Capture Module

WHT

(not used)

RED

 

BRN

AC LOSS

YEL

AC ON

GRA

 

ON

 

 

 

 

1

2

3

4

5

(RADIO TROUBLE)

BLK GRN YEL

RED

AC

 

 

ERTH GND

 

GND

 

 

TX

 

 

RX

 

AC

OUT+

1

 

 

DC+

 

E

Facility Ground

Fire Panel Main Dialer

Fire Panel Backup Dialer

To

To

To

STATUS

MESSAGE

FAULT

 

 

iGSM Comm

 

 

(AC ON)

 

 

Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR EXTERNAL ANTENNA

 

 

 

 

50 OHM MMCX ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

BLK

GRA

OUT-

OUTPUT

 

 

 

 

 

ACTIV

 

 

 

 

 

 

 

 

 

 

DC-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N/U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT+

2

 

 

 

 

 

 

DC+

OUTPUT

 

 

 

 

 

 

OUT-

 

 

 

 

 

 

 

 

 

 

 

 

DC-

 

 

 

 

 

 

N/U

 

 

 

 

 

 

 

 

 

BATTERY

 

 

 

 

 

 

 

 

VIO

GRN

YEL

RED

CONDUIT

To Router

To Fire Panel

To Fire Panel

BLK

 

 

7720P

 

 

 

 

PROGRAMMER

 

 

 

 

PORT

 

 

 

 

 

TB 1

 

 

 

 

 

1

 

 

 

 

 

2

+12V In

 

 

 

 

3

 

 

 

 

 

 

 

 

4

GND

 

 

 

 

5

ECP In

 

 

 

 

 

 

6

ECP Out

 

 

 

 

 

 

 

7

 

 

 

 

 

8

 

 

 

 

 

9

 

 

 

 

 

10

 

 

 

 

 

11

FLT Out

 

 

 

 

 

 

 

 

 

 

 

 

7720P PROGRAMMER PORT

 

 

 

 

 

 

NOT FOR TELEPHONE SERVICE USE!

 

 

PRIMARY POWER: 9 - 16.5 VAC

 

 

 

 

CURRENT: 900mA PEAK, 70mA STANDBY

 

 

 

 

BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP

 

 

 

FCC:XXXXXXXXXX IC: YYYYYYYYYY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RSSI/MODE

 

 

 

 

 

 

 

 

 

GPRS M1 M0 RSSI

IBS

 

INDICATORS

 

 

 

 

 

 

 

 

 

 

MODE & STATUS

TAMPER

 

 

 

SWITCH

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTERNET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTIVITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDICATORS

FUSE

+BATTERY

7AH

(not supplied)

Use a Honeywell 712BNP,

Yuasa NP7-12, or equivalent.

IPGSM-DP-007-V2 [US Only]

NOTES All circuits are power limited except the backup battery which is non-power limited.

Non-power limited wiring must be separated from the power limited wiring by at least 1/4 inch.

If desired, use a Honeywell 955WH Tamper Switch with the 28-2 bracket.

Image 15
Contents IPGSM-DP Contents Installation General InformationOperation Register the Communications Module with AlarmNet Activate the SIM and Setup the Customer AccountMount and Wire Determine the Signal Strength and Select a LocationPowerBoost1 Conduit Transformer N81677720P Programmer Program the Communications ModuleTest the System Configure the Fire PanelIPGSM-DP Trouble Detection Information Dialer Capture Module InformationLED Display Information Active PowerBoost1 Module InformationOFF Normal Slow Blink Loss of communication with IGSM Communications Module InformationRF Specifications IPGSM-DP SpecificationsPage + Battery Wiring DiagramÊ800-08074AŠ

IPGSM-DP specifications

The Honeywell IPGSM-DP is an advanced communication device specifically designed for alarm signaling and monitoring in contemporary security systems. This state-of-the-art unit is engineered to enhance the efficiency and reliability of alarm communications, serving as an integral part of home and business security solutions.

One of the main features of the IPGSM-DP is its dual-path communication capability, allowing it to connect via both cellular networks and the internet. This dual communication method ensures that security signals are transmitted even in situations where traditional phone lines may fail or be compromised. This capability is particularly crucial in maintaining a reliable line of communication between alarm systems and monitoring stations.

In terms of technology, the IPGSM-DP utilizes a robust GSM (Global System for Mobile Communications) module for cellular communication. This technology provides high-speed data transmission, which is essential for sending real-time alerts and notifications to security personnel or end-users. This feature enhances the overall responsiveness of the alarm system, enabling swift action in the event of a security breach.

Moreover, the IPGSM-DP is compatible with various alarm control panels, making it a versatile addition to existing security setups. It seamlessly integrates with both Honeywell and third-party systems, allowing users to upgrade their alarm capabilities without overhauling their entire security infrastructure.

The device also boasts advanced encryption technology, which serves to protect the integrity of the communication channels. This security feature is vital in safeguarding sensitive information and ensuring that alarm signals cannot be intercepted or tampered with.

In terms of characteristics, the IPGSM-DP is designed with user-friendliness in mind. It comes with an intuitive LED indicator that provides visual feedback on operational status, signal strength, and any potential issues that may arise. The compact design allows for easy installation in various locations within a property, minimizing disruption to the environment.

Furthermore, the Honeywell IPGSM-DP supports multiple protocols, including Contact ID and SIA, thereby ensuring compatibility with a wide range of monitoring stations and allowing for flexible deployment in diverse security scenarios. Enhanced diagnostic capabilities further simplify troubleshooting and maintenance of the device, ensuring long-term reliability.

In summary, the Honeywell IPGSM-DP is a cutting-edge communication device offering dual-path communication, GSM technology, compatibility with multiple alarm systems, and advanced security features. Its distinctive characteristics make it an excellent choice for enhancing the efficiency and reliability of alarm monitoring and signaling in various security applications.