General Information

The IPGSM-DP Commercial Fire Communicator (henceforth referred to as IPGSM-DP) includes everything you need to upgrade a commercial fire system that previously reported by POTS to a system that uses the Internet as its primary reporting path, and uses a GSM cellular reporting path as a backup. In addition, this communicator utilizes a sophisticated power module (PowerBoost1) that monitors and reports AC power loss, low battery, and missing battery conditions.

Package Contents

Red Fire Cabinet and Back Plate

Antenna and Mounting Adapter

LED Display board

Cam Lock with Key

PowerBoost1

Mounting Rails (for above)

Dialer Capture Module

Battery harness

Hardware Bag

iGSM Communications Module

Wall Outlet Box (P/N K14358)

Transformer, 18VAC (N8167)

50 ohm cable assembly

Ferrite Filter

 

Compatible Fire Panels

The IPGSM-DP works with Fire Panels that use the Contact ID communication format as described in the SIA DC-05 Standard. After completing the field installation, verify communications with the central station is successful by sending several events. Also, get confirmation that these events were received.

Note: For a fire panel that has more than 9 active partitions, the first 9 partitions are reported to the central station uniquely. Beyond 9 partitions, only the 2nd digit of the partition is reported along with a leading zero (example partition 14 is reported as 04). The installer must inform the central station of this condition.

Operation

The IPGSM-DP replaces the fire panel's POTS communications path. When an event occurs, the fire panel goes off-hook to dial the central station. The IPGSM-DP detects the off-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial tone, it begins dialing the central station. The IPGSM-DP considers the three second period after dialing as the number dialing has been completed. After the dialing is completed, the Dialer Capture Module returns a handshake to the fire panel.

The fire panel then sends the contact ID reports to the IPGSM-DP, which in turn sends a kiss-off after the report is successfully received from the fire panel. Within the IPGSM-DP, the Dialer Capture Module sends the contact ID reports over the ECP bus to the iGSM Communications Module. When all the reports are sent, the fire panel goes on-hook. The IPGSM-DP then transmits the messages to the central station (either over the internet or the GSM network).

Installation

UL Compliance

To meet UL864/NFPA, ensure the following:

IPGSM-DP must be installed in accordance with NFPA (National Fire Protection Association) standards 70 and 72.

IPGSM-DP must be mounted in the same room and within 20 feet of the fire panel. The wiring must be routed through conduit.

IPGSM-DP, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be provided with appropriate standby power.

IPGSM-DP must use a 7AH battery (not supplied) to provide 24-hour backup capability.

1

Image 3
Contents IPGSM-DP Contents Installation General InformationOperation Register the Communications Module with AlarmNet Activate the SIM and Setup the Customer AccountMount and Wire Determine the Signal Strength and Select a LocationPowerBoost1 Conduit Transformer N81677720P Programmer Program the Communications ModuleTest the System Configure the Fire PanelIPGSM-DP Trouble Detection Information Dialer Capture Module InformationLED Display Information Active PowerBoost1 Module InformationOFF Normal Slow Blink Loss of communication with IGSM Communications Module InformationRF Specifications IPGSM-DP SpecificationsPage + Battery Wiring DiagramÊ800-08074AŠ

IPGSM-DP specifications

The Honeywell IPGSM-DP is an advanced communication device specifically designed for alarm signaling and monitoring in contemporary security systems. This state-of-the-art unit is engineered to enhance the efficiency and reliability of alarm communications, serving as an integral part of home and business security solutions.

One of the main features of the IPGSM-DP is its dual-path communication capability, allowing it to connect via both cellular networks and the internet. This dual communication method ensures that security signals are transmitted even in situations where traditional phone lines may fail or be compromised. This capability is particularly crucial in maintaining a reliable line of communication between alarm systems and monitoring stations.

In terms of technology, the IPGSM-DP utilizes a robust GSM (Global System for Mobile Communications) module for cellular communication. This technology provides high-speed data transmission, which is essential for sending real-time alerts and notifications to security personnel or end-users. This feature enhances the overall responsiveness of the alarm system, enabling swift action in the event of a security breach.

Moreover, the IPGSM-DP is compatible with various alarm control panels, making it a versatile addition to existing security setups. It seamlessly integrates with both Honeywell and third-party systems, allowing users to upgrade their alarm capabilities without overhauling their entire security infrastructure.

The device also boasts advanced encryption technology, which serves to protect the integrity of the communication channels. This security feature is vital in safeguarding sensitive information and ensuring that alarm signals cannot be intercepted or tampered with.

In terms of characteristics, the IPGSM-DP is designed with user-friendliness in mind. It comes with an intuitive LED indicator that provides visual feedback on operational status, signal strength, and any potential issues that may arise. The compact design allows for easy installation in various locations within a property, minimizing disruption to the environment.

Furthermore, the Honeywell IPGSM-DP supports multiple protocols, including Contact ID and SIA, thereby ensuring compatibility with a wide range of monitoring stations and allowing for flexible deployment in diverse security scenarios. Enhanced diagnostic capabilities further simplify troubleshooting and maintenance of the device, ensuring long-term reliability.

In summary, the Honeywell IPGSM-DP is a cutting-edge communication device offering dual-path communication, GSM technology, compatibility with multiple alarm systems, and advanced security features. Its distinctive characteristics make it an excellent choice for enhancing the efficiency and reliability of alarm monitoring and signaling in various security applications.