9 Appliance Preparation

A. Secure and Level the Appliance

WARNING! Risk of Fire! Prevent contact with:

Sagging or loose insulation

Insulation backing or plastic

Framing and other combustible materials

Block openings into the chase to prevent entry of blown-in insulation. Make sure insulation and other materials are secured.

DO NOT notch the framing around the appliance standoffs.

Failure to maintain air space clearance may cause overheating and fire.

The diagram shows how to properly position and secure the appliance (see Figure 9.1). Nailing tabs are provided to secure the appliance to the framing members.

Bend out nailing tabs on each side.

Place the appliance into position.

Keep nailing tabs flush with the framing.

Level the appliance from side to side and front to back.

Shim the appliance as necessary. It is acceptable to use wood shims underneath the appliance.

Secure the appliance to the framing by using nails or screws through the nailing tabs.

Secure the appliance to the floor by inserting two screws through the pilot holes at the bottom of the appliance.

Nailing Tabs (both sides)

Figure 9.1 Proper Positioning and Securing of an Appliance

Heatilator • ICON DV-IDV Series • 4042-575 • Rev K • 11/08

31

Image 31
Contents What to do if you smell gas Installation and OperationHomeowner Reference Information CongratulationsInstaller Guide Table of ContentsUser Guide Troubleshooting Hearth & Home Technologies Limited Warranty WarrantyLimited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Decorative Doors and Fronts Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceLighting Instructions IPI For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Maintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelect Appliance Location Framing and ClearancesModel # Clearances Construct the Appliance ChaseRough Opening Model # Width Height Depth Vent pipe Mantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyTop Vent Horizontal Termination Vent DiagramsTwo Elbows Two 45 Elbows replacing One 90 ElbowV1 min V1 max H1+H2 max H1+H2+H3 max Three Elbows Installed VerticallyTop Vent Vertical Termination Install Flue RestrictorNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Secure and Level the Appliance Appliance PreparationAssemble Pipe Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Vent SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Metal Roof FlashingCaulk 13 Assembling the Storm Collar Assemble and Install Storm CollarSLP-FS Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInterior Install Horizontal Termination CapGas Connection Gas InformationFuel Conversion Gas PressureElectrical Service and Repair Wiring RequirementsOptional Accessories Requirements Intellifire Ignition System WiringRemove Two Screws From Bracket Junction Box InstallationFacing Material FinishingModel Finished Fireplace Opening Noncombustible Finishing MaterialAppliance Setup Placing First Top Log IDV4833 Install the LogsPlace Lava Rock and Rockwool Placement of Rockwool and Lava RockRemoving/Replacing Glass Assembly Glass Panel AssemblyEyelet Rod Support Bottom Front Hearth Refractory Installing External RefractoriesInstall Side Refractories Open Refractory Package Figure24 Air Shutter Adjustment Air Shutter SettingSymptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Will not ignite. If the pilot Reference Materials Appliance Dimension DiagramDVP Vent Components Vent Components DiagramsBEK DVP-BEK2 DVP-TVHW Horizontal Termination Cap DVP-TRAPDVP-HRC-SS IDV4833IT, IDV4833IH ÎC. Service PartsIPI Valve Assembly IDV6247IT, IDV6247IH Service PartsIDV6247 Traditional Refractory Pre GA1732717 Post GA1732717 Description Optional ComponentsContact Information

IDV6247ILH, IDV6247IH, IDV4833ILH, IDV4833ILT, IDV6247ILT specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, offering a range of innovative and efficient products designed for modern living. Among their impressive lineup are the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT models. These fireplaces are engineered to provide both aesthetic warmth and functional heating, catering to various consumer preferences and home designs.

The IDV6247IT is a remarkable direct vent gas fireplace that offers a spacious viewing area. With its clean lines and contemporary aesthetics, it seamlessly integrates into any living space. Equipped with advanced burner technology, it delivers realistic flames while maximizing efficiency. The model features a variety of customizable options, including remote controls and programmable thermostats, allowing users to tailor their heating preferences to suit their lifestyle.

Similarly, the IDV4833IT and IDV4833IH models offer versatile heating solutions. The IDV4833IT is designed for those seeking a traditional yet modern fireplace experience. With its customizable log sets and flame patterns, it creates a cozy ambiance. The IDV4833IH model distinguishes itself with its enhanced heating capabilities, boasting an impressive BTU output that quickly warms up expansive areas, making it ideal for larger homes.

A notable feature across these models is the innovative IntelliFire technology, which provides reliable ignition and easy operation. This ensures that the fireplace ignites effortlessly, with users able to enjoy the warmth and glow with a simple push of a button. Additionally, the fireplaces utilize a closed combustion system, drawing air from outside, which significantly increases efficiency and reduces heat loss.

For homeowners interested in a more rustic look, the IDV6247ILT and IDV4833ILT models incorporate traditional design elements. These units provide a luxurious feel with their detailed craftsmanship and realistic logs. The high-efficiency design allows for reduced emissions and lower fuel consumption, promoting a more sustainable lifestyle without compromising on warmth or comfort.

In conclusion, Hearth and Home Technologies continues to lead the way in the hearth market with their innovative IDV series. Whether you prefer contemporary elegance or classic charm, models like the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT deliver not just on style, but also on performance and efficiency. With a focus on user-friendly features and advanced technology, these fireplaces are perfect for any modern home, ensuring a warm and inviting atmosphere for years to come.