G. Install RF4-8

The RF4-8 may be used in place of the roof flashing and storm collar.

Pipe must be supported within 12 in. (305 mm) of the roofline using plumbers strapping or an SLP-FS when us- ing the RF4-8 Flashing. Refer to Sect. 10.C. Secure the Vent Sections.

Secure with 4 screws no longer than 1/2 in./13 mm

SLP-FS

Figure 10.15 Secure Pipe with SLP-FS

Trim the rubber boot (using scissors or a utility knife), cutting along the marked measurement lines. See Figure 10.16. Use the 210 mm line for DVP pipe.

Lubricate pipe or flue with water and slide the flashing down. It may be necessary to trim the top shingles around the base of the rubber boot to ensure a good fit.

Draw around flashing, remove.

Apply silicone sealant to roof inside the lines (Figure 10.17)

Lubricate pipe or flue with water and slide flashing down. Seat firmly in sealant. Nail roof flashing to the roof.

Apply silicone sealant on the top outside of the base plate on the sides and on top edge. See Figure 10.18. Install shingles, Apply sealant at the top edge of the rubber boot. See Figure 10.19.

We recommend that you top coat with conventional acrylic house paint to improve the appearance of your galvanized base flashing.

The SLP-FS shown in this photo will not be used with DVP pipe.

SLP-FS

Figure 10.17 Apply Sealant

Apply Sealant

Top & Partial Sides

Figure 10.18 Slide Flashing Down, Secure & Apply Sealant

Silicone Sealant (top of boot)

Shingles Trimmed

Flashing over

Shingles over

Shingles

Flashing

 

Figure 10.19 Installation Complete

Figure 10.16 Trim Rubber Boot

36

Heatilator • ICON DV-IDV Series • 4042-575 • Rev K • 11/08

Image 36
Contents Installation and Operation What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Installer GuideUser Guide Troubleshooting Warranty Hearth & Home Technologies Limited WarrantyLimited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Gas Fireplace Safety Operating InstructionsYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesClear Space Decorative Doors and FrontsFor Your Safety Read Before Lighting Lighting Instructions IPIFrequently Asked Questions Initial Break-in ProcedureAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardFraming and Clearances Select Appliance LocationModel # Construct the Appliance Chase ClearancesRough Opening Model # Width Height Depth Vent pipe Mantel and Wall Projections MantelsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal TerminationTwo 45 Elbows replacing One 90 Elbow Two ElbowsV1 min V1 max H1+H2 max H1+H2+H3 max Installed Vertically Three ElbowsInstall Flue Restrictor Top Vent Vertical TerminationNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Secure and Level the ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsInstall Metal Roof Flashing Disassemble Vent SectionsCaulk Assemble and Install Storm Collar 13 Assembling the Storm CollarInstall RF4-8 SLP-FSInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap InteriorGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Optional Accessories RequirementsIntellifire Ignition System Wiring Electrical Service and RepairJunction Box Installation Remove Two Screws From BracketFinishing Facing MaterialModel Noncombustible Finishing Material Finished Fireplace OpeningAppliance Setup Install the Logs Placing First Top Log IDV4833Placement of Rockwool and Lava Rock Place Lava Rock and RockwoolGlass Panel Assembly Removing/Replacing Glass AssemblyEyelet Rod Support Installing External Refractories Install Side RefractoriesOpen Refractory Package Figure Bottom Front Hearth RefractoryAir Shutter Setting 24 Air Shutter AdjustmentTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Will not ignite. If the pilot Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsBEK DVP-BEK2 DVP-TVHW DVP-TRAP Horizontal Termination CapDVP-HRC-SS ÎC. Service Parts IDV4833IT, IDV4833IHIPI Valve Assembly Service Parts IDV6247IT, IDV6247IHIDV6247 Traditional Refractory Pre GA1732717 Post GA1732717 Optional Components DescriptionContact Information

IDV6247ILH, IDV6247IH, IDV4833ILH, IDV4833ILT, IDV6247ILT specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, offering a range of innovative and efficient products designed for modern living. Among their impressive lineup are the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT models. These fireplaces are engineered to provide both aesthetic warmth and functional heating, catering to various consumer preferences and home designs.

The IDV6247IT is a remarkable direct vent gas fireplace that offers a spacious viewing area. With its clean lines and contemporary aesthetics, it seamlessly integrates into any living space. Equipped with advanced burner technology, it delivers realistic flames while maximizing efficiency. The model features a variety of customizable options, including remote controls and programmable thermostats, allowing users to tailor their heating preferences to suit their lifestyle.

Similarly, the IDV4833IT and IDV4833IH models offer versatile heating solutions. The IDV4833IT is designed for those seeking a traditional yet modern fireplace experience. With its customizable log sets and flame patterns, it creates a cozy ambiance. The IDV4833IH model distinguishes itself with its enhanced heating capabilities, boasting an impressive BTU output that quickly warms up expansive areas, making it ideal for larger homes.

A notable feature across these models is the innovative IntelliFire technology, which provides reliable ignition and easy operation. This ensures that the fireplace ignites effortlessly, with users able to enjoy the warmth and glow with a simple push of a button. Additionally, the fireplaces utilize a closed combustion system, drawing air from outside, which significantly increases efficiency and reduces heat loss.

For homeowners interested in a more rustic look, the IDV6247ILT and IDV4833ILT models incorporate traditional design elements. These units provide a luxurious feel with their detailed craftsmanship and realistic logs. The high-efficiency design allows for reduced emissions and lower fuel consumption, promoting a more sustainable lifestyle without compromising on warmth or comfort.

In conclusion, Hearth and Home Technologies continues to lead the way in the hearth market with their innovative IDV series. Whether you prefer contemporary elegance or classic charm, models like the IDV6247IT, IDV4833IT, IDV4833IH, IDV6247ILT, and IDV4833ILT deliver not just on style, but also on performance and efficiency. With a focus on user-friendly features and advanced technology, these fireplaces are perfect for any modern home, ensuring a warm and inviting atmosphere for years to come.